Photothermal enhancement in sensitivity of lateral flow assays for detection of E-coli O157:H7

被引:35
|
作者
Shirshahi, Vahid [1 ,4 ]
Tabatabaei, Seyed Nasrollah [1 ]
Hatamie, Shadie [3 ]
Saber, Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Sch Adv Technol Med, Dept Med Nanotechnol, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[3] Stem Cell Technol Res Ctr, Tehran, Iran
[4] Shahroud Univ Med Sci, Sch Med, Shahroud, Iran
关键词
Sensitivity improvement; Signal amplification; Photothermal quantification; Lateral flow assay; Reduced graphene oxide; REDUCED GRAPHENE OXIDE; PAPER SENSOR; DEVICE;
D O I
10.1016/j.colsurfb.2019.110721
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Lateral flow immunoassay (LFA) is a well-known point-of-care technology for the detection of various analytes. However, low sensitivity and lack of quantitative results are some of its critical drawbacks. Here we report a photothermal enhanced lateral flow sensor on the basis of the photothermal properties of reduced graphene oxide (rGO) for the detection of E-coli O157:H7 as a model pathogen. The calibration curve of the photothermal method exhibited a linear range from 5 x 10(5) to 5 x 10(7) CFU/ml with a correlation coefficient of R-2 = 0.96 and a regression equation of y = 8.1x-43 for standard bacteria solutions in phosphate buffer. The limit of detection was similar to 5 x 10(5) CFU/ml for standard bacteria solutions, which was a 10-fold enhancement in sensitivity compared to the qualitative results. Specificity experiments showed that the photothermal method can only detect the target bacteria among 6 types of bacteria strains. It was confirmed that the developed technique could be a highly potential method for the rapid detection field because it can provide fast quantitative results with improved sensitivity.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [31] Detection of E-coli O157: H7 Using Mannose-functionalized Hydrogels
    Zhou Li-Xia
    He Ding-Geng
    He Xiao-Xiao
    Qing Zhi-He
    Wang Ke-Min
    Cao Jie
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2012, 33 (04): : 678 - 682
  • [32] Research suggests strategy for curbing E-coli O157:H7
    不详
    ASM NEWS, 1998, 64 (11): : 619 - 619
  • [33] Scientists test for E-coli O157:H7 in Salinas Valley
    不详
    CALIFORNIA AGRICULTURE, 2007, 61 (01) : 6 - 6
  • [34] Sensitivity of direct plating for detection of high levels of E-Coli O157:H7 in bovine fecal samples
    Sanderson, M. W.
    Sreerama, S.
    Nagaraja, T. G.
    CURRENT MICROBIOLOGY, 2007, 55 (02) : 158 - 161
  • [35] Monitoring and mitigation of E-coli O157:H7 in commercial dairies
    McAllister, TA
    Stanford, K
    Bach, SJ
    ADVANCES IN DAIRY TECHNOLOGY, VOL 17, 2005, 17 : 227 - 246
  • [36] Transcriptomic insights into the interaction of E-coli O157:H7 with lettuce
    Brandl, M. T.
    PHYTOPATHOLOGY, 2011, 101 (06) : S212 - S212
  • [37] Evaluation of methods for detection of Escherichia coli O157:H7 in milk, and occurrence of E-coli O157: H7 in ex-farm raw milks in Hungary
    Hucker, A.
    Mike-Schummel, I.
    Unger, A.
    Varga, L.
    MILCHWISSENSCHAFT-MILK SCIENCE INTERNATIONAL, 2006, 61 (01): : 11 - 14
  • [38] The influence of melatonin on growth of E-coli O157:H7 in pure culture and exogenous melatonin on faecal shedding of E-coli O157:H7 in experimentally infected wethers
    Schultz, C. L.
    Edrington, T. S.
    Callaway, T. R.
    Schroeder, S. B.
    Hallford, D. M.
    Genovese, K. J.
    Anderson, R. C.
    Nisbet, D. J.
    LETTERS IN APPLIED MICROBIOLOGY, 2006, 43 (01) : 105 - 110
  • [39] E. coli O157: H7
    Fernandez, Treor Francis
    VETERINARY WORLD, 2008, 1 (03) : 83 - 87
  • [40] Performance of the ImmunoCard STAT!: E. coli O157:H7 test for detection of Escherichia coli O157:H7 in stools
    Mackenzie, A
    Orrbine, E
    Hyde, L
    Benoit, M
    Chan, F
    Park, C
    Alverson, J
    Lembke, A
    Hoban, D
    Kennedy, W
    JOURNAL OF CLINICAL MICROBIOLOGY, 2000, 38 (05) : 1866 - 1868