Photothermal enhancement in sensitivity of lateral flow assays for detection of E-coli O157:H7

被引:35
|
作者
Shirshahi, Vahid [1 ,4 ]
Tabatabaei, Seyed Nasrollah [1 ]
Hatamie, Shadie [3 ]
Saber, Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Sch Adv Technol Med, Dept Med Nanotechnol, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[3] Stem Cell Technol Res Ctr, Tehran, Iran
[4] Shahroud Univ Med Sci, Sch Med, Shahroud, Iran
关键词
Sensitivity improvement; Signal amplification; Photothermal quantification; Lateral flow assay; Reduced graphene oxide; REDUCED GRAPHENE OXIDE; PAPER SENSOR; DEVICE;
D O I
10.1016/j.colsurfb.2019.110721
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Lateral flow immunoassay (LFA) is a well-known point-of-care technology for the detection of various analytes. However, low sensitivity and lack of quantitative results are some of its critical drawbacks. Here we report a photothermal enhanced lateral flow sensor on the basis of the photothermal properties of reduced graphene oxide (rGO) for the detection of E-coli O157:H7 as a model pathogen. The calibration curve of the photothermal method exhibited a linear range from 5 x 10(5) to 5 x 10(7) CFU/ml with a correlation coefficient of R-2 = 0.96 and a regression equation of y = 8.1x-43 for standard bacteria solutions in phosphate buffer. The limit of detection was similar to 5 x 10(5) CFU/ml for standard bacteria solutions, which was a 10-fold enhancement in sensitivity compared to the qualitative results. Specificity experiments showed that the photothermal method can only detect the target bacteria among 6 types of bacteria strains. It was confirmed that the developed technique could be a highly potential method for the rapid detection field because it can provide fast quantitative results with improved sensitivity.
引用
下载
收藏
页数:6
相关论文
共 50 条
  • [1] Plasmonic enhancement in lateral flow sensors for improved sensing of E-coli O157:H7
    Ren, Wen
    Ballou, Dexter R.
    FitzGerald, Ryan
    Irudayaraj, Joseph
    BIOSENSORS & BIOELECTRONICS, 2019, 126 : 324 - 331
  • [2] Validation of a Modified ANSR® for E-coli O157:H7 Method for Detection of E-coli O157:H7 in Select Foods
    Alles, Susan
    Roman, Brooke
    Quynh-Nhi Le
    Hosking, Edan
    Colangelo, Wesley
    Tovar, Eric
    Biswas, Preetha
    Mozola, Mark
    Donofrio, Robert
    JOURNAL OF AOAC INTERNATIONAL, 2019, 102 (01) : 96 - 107
  • [3] On the trial of E-coli O157:H7
    Lewis, R
    SCIENTIST, 1999, 13 (21): : 10 - 10
  • [4] The Wishaw E-coli O157:H7 outbreak
    Kohli, HS
    NATIONAL MEDICAL JOURNAL OF INDIA, 1997, 10 (03): : 145 - 146
  • [5] Immunohistochemical detection of E-coli O157:H7 in colonic tissue
    Alt, E
    Sigal, S
    Su, C
    Steinberg, JJ
    Kress, Y
    Brandt, L
    LABORATORY INVESTIGATION, 1996, 74 (01) : 299 - 299
  • [6] Validation of a method for the detection of E-coli O157:H7 in foods
    Scotter, S
    Aldridge, M
    Capps, K
    FOOD CONTROL, 2000, 11 (02) : 85 - 95
  • [7] A microsystem for extraction, capture and detection of E-Coli O157:H7
    Ashis Sen
    Tom Harvey
    Jan Clausen
    Biomedical Microdevices, 2011, 13 : 705 - 715
  • [8] Recognizing E-coli O157:H7 infection
    Greenwald, DA
    Brandt, LJ
    HOSPITAL PRACTICE, 1997, 32 (04): : 123 - &
  • [9] THE BEHAVIOR OF E-COLI O157:H7 IN SUCUK
    Apaydin, Guezin
    Ceylan, Ziya Goekalp
    Kaya, Muekerrem
    JOURNAL OF FOOD PROCESSING AND PRESERVATION, 2009, 33 (06) : 827 - 836
  • [10] A microsystem for extraction, capture and detection of E-Coli O157:H7
    Sen, Ashis
    Harvey, Tom
    Clausen, Jan
    BIOMEDICAL MICRODEVICES, 2011, 13 (04) : 705 - 715