Influence of single versus multiple actuations on the particle size distribution of beclometasone dipropionate metered-dose inhalers

被引:3
|
作者
Feddah, MR [1 ]
Davies, NM [1 ]
机构
[1] Univ Sydney, Fac Pharm, Sydney, NSW, Australia
关键词
D O I
10.1211/0022357021549
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The particle size distributions of beclometasone dipropionate delivered from Becotide and Respocort inhalers after single and multiple actuations were investigated using the Andersen Mark 11 Cascade impactor and the drug was quantified using high performance liquid chromatography. The fine particle mass and the mass median aerodynamic diameter were calculated. An apparent increase in mass median aerodynamic diameter was observed when the number of actuations increased. In addition, the fine particle mass decreased as the number of actuations increased. When performing and analysing cascade impaction study data differences between single versus multiple actuations must be considered. Regulatory guidelines should be amended to stipulate the number of actuations to be loaded into devices used to evaluate the particle size distribution of inhaled aerosol products.
引用
收藏
页码:1055 / 1061
页数:7
相关论文
共 50 条
  • [31] Prediction of the particle size distribution of the aerosol generated by a pressurized metered-dose inhaler
    de Charras, Yamila L.
    Veronica Ramirez-Rigo, M.
    Bertin, Diego E.
    POWDER TECHNOLOGY, 2022, 399
  • [32] Metered dose inhalers .3. Metaproterenol sulphate; particle size distribution and dose uniformity
    Cyr, TD
    Duhaime, RM
    Graham, SJ
    Ormsby, ED
    Lawrence, RC
    LeBelle, MJ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (11) : 1709 - 1718
  • [33] THE INFLUENCE OF AGE, DIAGNOSIS, AND GENDER ON PROPER USE OF METERED-DOSE INHALERS
    GOODMAN, DE
    ISRAEL, E
    ROSENBERG, M
    JOHNSTON, R
    WEISS, ST
    DRAZEN, JM
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (05) : 1256 - 1261
  • [34] Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry
    Alatrash, Abubaker
    Matida, Edgar
    JOURNAL OF AEROSOL MEDICINE AND PULMONARY DRUG DELIVERY, 2016, 29 (06) : 501 - 513
  • [35] SIZE DISTRIBUTIONS AND LUNG DEPOSITION OF SUBMICROMETER PARTICLES FROM METERED-DOSE INHALERS
    LIN, RH
    WANG, CR
    LI, CS
    ENVIRONMENT INTERNATIONAL, 1994, 20 (02) : 161 - 167
  • [36] Factors Influencing Aerodynamic Particle Size Distribution of Suspension Pressurized Metered Dose Inhalers
    Poonam Sheth
    Stephen W. Stein
    Paul B. Myrdal
    AAPS PharmSciTech, 2015, 16 : 192 - 201
  • [37] Tuning Aerosol Particle Size Distribution of Metered Dose Inhalers Using Cosolvents and Surfactants
    Saleem, Imran Y.
    Smyth, Hugh D. C.
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [38] Factors Influencing Aerodynamic Particle Size Distribution of Suspension Pressurized Metered Dose Inhalers
    Sheth, Poonam
    Stein, Stephen W.
    Myrdal, Paul B.
    AAPS PHARMSCITECH, 2015, 16 (01): : 192 - 201
  • [39] Comparison of the efficacy and safety of high doses of beclometasone dipropionate suspension for nebulization and beclometasone dipropionate via a metered-dose inhaler in steroid-dependent adults with moderate to severe asthma
    Grzelewska-Rzymowska, I
    Kroczynska-Bednarek, J
    Zarkovic, J
    RESPIRATORY MEDICINE, 2003, 97 : S21 - S26
  • [40] AERODYNAMIC SIZE DISTRIBUTION OF METERED-DOSE BRONCHODILATOR AEROSOLS
    HILLER, C
    MAZUMDER, M
    WILSON, D
    BONE, R
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1978, 118 (02): : 311 - 317