Diagnostic accuracy of transvaginal sonography for detecting parametrial involvement in women with deep endometriosis: systematic review and meta-analysis

被引:23
|
作者
Guerriero, S. [1 ,2 ]
Martinez, L. [3 ]
Gomez, I. [4 ]
Pascual, M. A. [5 ]
Ajossa, S. [6 ]
Pagliuca, M. [6 ]
Alcazar, J. L. [7 ]
机构
[1] Policlin Univ Duilio Casula, Ctr Integrato Procreaz Med Assistita PMA & Diagno, Monserrato, Italy
[2] Univ Cagliari, Cagliari, Italy
[3] Reina Sofia Univ Hosp, Dept Gynecol, Murcia, Spain
[4] Virgen de la Arrixaca Univ Hosp, Dept Obstet & Gynecol, Murcia, Spain
[5] Hosp Univ Dexeus, Dept Obstet Gynecol & Reprod, Barcelona, Spain
[6] Univ Cagliari, Policlin Univ Duilio Casula, Dept Obstet & Gynecol, Cagliari, Italy
[7] Clin Univ Navarra, Dept Obstet & Gynecol, Avenida Pio 12 36, Pamplona 3110, Spain
关键词
endometriosis; parametrium; transvaginal ultrasound; INFILTRATING ENDOMETRIOSIS; ULTRASOUND; ULTRASONOGRAPHY;
D O I
10.1002/uog.23754
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To evaluate the accuracy of transvaginal sonography (TVS) for detecting parametrial deep endometriosis, using laparoscopy as the reference standard. Methods A search was performed in PubMed/MEDLINE and Web of Science for studies evaluating TVS for detecting parametrial involvement in women with suspected deep endometriosis, as compared with laparoscopy, from January 2000 to December 2020. The Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used to evaluate the quality of the studies. Pooled sensitivity, specificity and positive and negative likelihood ratios for TVS in the detection of parametrial deep endometriosis were calculated, and the post-test probability of parametrial deep endometriosis following a positive or negative test was determined. Results The search identified 134 citations. Four studies, comprising 560 patients, were included in the analysis. The mean prevalence of parametrial deep endometriosis at surgery was 18%. Overall, the pooled estimated sensitivity, specificity and positive and negative likelihood ratios of TVS in the detection of parametrial deep endometriosis were 31% (95% CI, 10-64%), 98% (95% CI, 95-99%), 18.5 (95% CI, 8.8-38.9) and 0.70 (95% CI, 0.46-1.06), respectively. The diagnostic odds ratio was 26 (95% CI, 10-68). Heterogeneity was high. Visualization of a lesion suspected to be parametrial deep endometriosis on TVS increased significantly the post-test probability of parametrial deep endometriosis. Conclusion TVS has high specificity but low sensitivity for the detection of parametrial deep endometriosis. (C) 2021 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
引用
收藏
页码:669 / 676
页数:8
相关论文
共 50 条
  • [11] Non-invasive Diagnostic Accuracy of Transvaginal Ultrasound in Patients with Bowel Endometriosis: A Systematic Review and Meta-analysis
    Alyami, Hebah Samran
    ANNALS OF MEDICAL AND HEALTH SCIENCES RESEARCH, 2021, 11 (01) : 1183 - 1187
  • [12] Diagnostic accuracy of Cancer Antigen 125 for endometriosis in symptomatic women: A systematic review and meta-analysis
    Hirsch, M.
    Duffy, J.
    Davis, C.
    Plana, M. N.
    Khan, K.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2016, 123 : 194 - 194
  • [13] Accuracy of cervical transvaginal sonography in predicting preterm birth in twins: A systematic review with meta-analysis
    Sanchez-Ramos, Luis
    Seavey, Michelle
    Kaunitz, Andrew
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 197 (06) : S51 - S51
  • [14] Diagnostic Performance of Transvaginal Ultrasound for Detecting Cervical Invasion In Women With Endometrial Carcinoma: A Systematic Review and Meta-analysis
    Luis Alcazar, Juan
    Perez, Lidia
    Guell, Olga
    Haro, Nuria
    Manzour, Nabil
    Chacon, Enrique
    Jurado, Matias
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (01) : 179 - 188
  • [15] Accuracy of transvaginal ultrasound for diagnosis of deep endometriosis in uterosacral ligaments, rectovaginal septum, vagina and bladder: systematic review and meta-analysis
    Guerriero, S.
    Ajossa, S.
    Minguez, J. A.
    Jurado, M.
    Mais, V.
    Melis, G. B.
    Alcazar, J. L.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2015, 46 (05) : 534 - 545
  • [16] Comparison of diagnostic accuracy of saline infusion sonohysterography, transvaginal sonography, and hysteroscopy in evaluating the endometrial polyps in women with abnormal uterine bleeding: a systematic review and meta-analysis
    Kaveh, Mania
    Sadegi, Kambiz
    Salarzaei, Morteza
    Parooei, Fateme
    VIDEOSURGERY AND OTHER MINIINVASIVE TECHNIQUES, 2020, 15 (03) : 403 - 415
  • [17] Diagnostic accuracy of transvaginal sonography for the diagnosis of adenomyosis: systematic review and metaanalysis
    Meredith, Susanna M.
    Sanchez-Ramos, Luis
    Kaunitz, Andrew M.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2009, 201 (01) : 107.e1 - 107.e6
  • [18] The Diagnostic Accuracy of Transvaginal Ultrasound for Detection of Ureteral Involvement in Deep Infiltrating Endometriosis
    Chway, Cizar
    Florez, Sandra
    Munoz, Maria Dolores
    Guerriero, Stefano
    Alcazar, Juan Luis
    JOURNAL OF ULTRASOUND IN MEDICINE, 2024, 43 (01) : 7 - 19
  • [19] Systematic review and meta-analysis of the diagnostic accuracy of ultrasonography for deep vein thrombosis
    Goodacre S.
    Sampson F.
    Thomas S.
    van Beek E.
    Sutton A.
    BMC Medical Imaging, 5 (1)
  • [20] Diagnostic accuracy of deep learning in orthopaedic fractures: a systematic review and meta-analysis
    Yang, S.
    Yin, B.
    Cao, W.
    Feng, C.
    Fan, G.
    He, S.