Effects of Interaural Pitch Matching and Auditory Image Centering on Binaural Sensitivity in Cochlear Implant Users

被引:1
|
作者
Kan, Alan [1 ]
Litovsky, Ruth Y. [1 ]
Goupell, Matthew J. [1 ,2 ]
机构
[1] Univ Wisconsin, Waisman Ctr, Madison, WI 53705 USA
[2] Univ Maryland, Dept Hearing & Speech Sci, College Pk, MD 20742 USA
来源
EAR AND HEARING | 2015年 / 36卷 / 03期
基金
美国国家卫生研究院;
关键词
Bilateral cochlear implants; Binaural sensitivity; Interaural mismatch; PLACE-OF-STIMULATION; PSYCHOMETRIC FUNCTION; TIME; DISCRIMINATION; HEARING; LEVEL; LOCALIZATION; DIFFERENCE; FREQUENCY; POSITION;
D O I
暂无
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objectives: In bilateral cochlear implant users, electrodes mapped to the same frequency range in each ear may stimulate different places in each cochlea due to an insertion depth difference of electrode arrays. This interaural place of stimulation mismatch can lead to problems with auditory image fusion and sensitivity to binaural cues, which may explain the large localization errors seen in many patients. Previous work has shown that interaural place of stimulation mismatch can lead to off-centered auditory images being perceived even though interaural time and level differences (ITD and ILD, respectively) were zero. Large interaural mismatches reduced the ability to use ITDs for auditory image lateralization. In contrast, lateralization with ILDs was still possible but the mapping of ILDs to spatial locations was distorted. This study extends the previous work by systematically investigating the effect of interaural place of stimulation mismatch on ITD and ILD sensitivity directly and examining whether "centering" methods can be used to mitigate some of the negative effects of interaural place of stimulation mismatch. Design: Interaural place of stimulation mismatch was deliberately introduced for this study. Interaural pitch-matching techniques were used to identify a pitch-matched pair of electrodes across the ears approximately at the center of the array. Mismatched pairs were then created by maintaining one of the pitch-matched electrodes constant, and systematically varying the contralateral electrode by two, four, or eight electrode positions (corresponding to approximately 1.5, 3, and 6 mm of interaural place of excitation differences). The stimuli were 300 msec, constant amplitude pulse trains presented at 100 pulses per second. ITD and ILD just noticeable differences (JNDs) were measured using a method of constant stimuli with a two-interval, two-alternative forced choice task. The results were fit with a psychometric function to obtain the JNDs. In experiment I, ITD and ILD JNDs were measured as a function of the simulated place of stimulation mismatch. In experiment II, the auditory image of mismatched pair was centered by adjusting the stimulation level according to a lateralization task. ITD and ILD JNDs were then remeasured and compared with the results of experiment I. Results: ITD and ILD JNDs were best (lowest thresholds) for pairs of electrodes at or near the pitch-matched pair. Thresholds increased systematically with increasing amounts of interaural mismatch. Deliberate and careful centering of auditory images did not significantly improve ITD JNDs but did improve ILD JNDs at very large amounts of simulated mismatch. Conclusions: Interaural place of stimulation mismatch decreases sensitivity to binaural cues that are important for accurate sound localization. However, deliberate and careful centering of auditory images does not seem to significantly counteract the effects of mismatch. Hence, to obtain maximal sound localization benefits of bilateral implantation, clinical and surgical techniques are needed that take into account differences in electrode array insertion depths across the ears.
引用
收藏
页码:E62 / E68
页数:7
相关论文
共 50 条
  • [21] Sensitivity of bilateral cochlear implant users to fine-structure and envelope interaural time differences
    Noel, Victor A.
    Eddington, Donald K.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2013, 133 (04): : 2314 - 2328
  • [22] Musical Pitch Discrimination by Cochlear Implant Users
    Ping, Lichuan
    Yuan, Meng
    Feng, Haihong
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2012, 121 (05): : 328 - 336
  • [23] A preliminary study to identify a neurophysiological correlate of electroacoustic pitch matching in cochlear implant users
    Tan, Chin-Tuan
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 1162 - 1165
  • [24] Enhancement of interaural level differences for bilateral cochlear implant users
    Gajecki, Tom
    Nogueira, Waldo
    HEARING RESEARCH, 2021, 409
  • [25] Impact of processing-latency induced interaural delay and level discrepancy on sensitivity to interaural level differences in cochlear implant users
    Koertje, Monika
    Stoever, Timo
    Baumann, Uwe
    Weissgerber, Tobias
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2023, 280 (12) : 5241 - 5249
  • [26] Impact of processing-latency induced interaural delay and level discrepancy on sensitivity to interaural level differences in cochlear implant users
    Monika Körtje
    Timo Stöver
    Uwe Baumann
    Tobias Weissgerber
    European Archives of Oto-Rhino-Laryngology, 2023, 280 : 5241 - 5249
  • [27] Auditory Reasoning Skills of Cochlear Implant Users
    Aslan, Filiz
    Yucel, Esra
    JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY, 2019, 15 (01): : 70 - 76
  • [28] Auditory cortical plasticity in cochlear implant users
    Glennon, Erin
    Svirsky, Mario A.
    Froemke, Robert C.
    CURRENT OPINION IN NEUROBIOLOGY, 2020, 60 : 108 - 114
  • [29] Binaural advantages in users of bimodal and bilateral cochlear implant devices
    Kokkinakis, Kostas
    Pak, Natalie
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2014, 135 (01): : EL47 - EL53
  • [30] Interaural Time-Delay Sensitivity in Bilateral Cochlear Implant Users: Effects of Pulse Rate, Modulation Rate, and Place of Stimulation
    Richard J.M. van Hoesel
    Gary L. Jones
    Ruth Y. Litovsky
    Journal of the Association for Research in Otolaryngology, 2009, 10 : 557 - 567