Comparative analysis of physical doses and biomarker changes in subjects underwent Computed Tomography, Positron Emission Tomography-Computed Tomography, and interventional procedures

被引:0
|
作者
Visweswaran, Shangamithra [1 ]
Raavi, Venkateswarlu [2 ]
Basheerudeen, Safa Abdul Syed [1 ]
Kanagaraj, Karthik [1 ]
Prasad, Akshaya [1 ]
Sekaran, Tamizh Selvan Gnana [3 ]
Pattan, Sudha [4 ]
Shanmugam, Panneerselvam [4 ]
Ozimuthu, Annalakshmi [5 ]
Joseph, Santhosh [6 ]
Perumal, Venkatachalam [1 ]
机构
[1] Sri Ramachandra Inst Higher Educ & Res Deemed Uni, Dept Human Genet, Chennai 600116, Tamil Nadu, India
[2] Sri Devaraj Urs Acad Higher Educ & Res Deemed Uni, Dept Cell Biol & Mol Genet, Kolar 563103, Karnataka, India
[3] NITTE Deemed Univ, Cent Res Lab, KS Hegde Med Acad, Mangalore 575018, Karnataka, India
[4] Sri Ramachandra Inst Higher Educ & Res Deemed Uni, Dept Radiol & Imaging Sci, Chennai 600116, Tamil Nadu, India
[5] Homi Bhabha Natl Inst, Safety Qual & Resource Management Grp, Hlth Safety & Environm Grp, Indira Gandhi Ctr Atom Res, Kalpakkam 603102, Tamil Nadu, India
[6] Sri Ramachandra Inst Higher Educ & Res Deemed Uni, Dept Neuroradiol, Chennai 600116, Tamil Nadu, India
关键词
Computed Tomography; Positron Emission Tomography; Computed; Tomography; Interventional procedures; Low dose ionizing radiation; Physical dose; Biological markers; DOUBLE-STRAND BREAKS; NATURAL RADIATION AREAS; IONIZING-RADIATION; CANCER-RISK; DNA-DAMAGE; CT SCANS; GAMMA-H2AX FOCI; SUBSEQUENT RISK; IN-VIVO; BLOOD-LYMPHOCYTES;
D O I
10.1016/j.mrgentox.2021.503404
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Even though the medical uses of ionizing radiation are well-acknowledged globally as vital tools for the improvement of human health, they also symbolize the major man-made sources of radiation exposure to the population. Estimation of absorbed dose and biological changes after radiation-based imaging might help to better understand the effects of low dose radiation. Because of this, we measured the Entrance Surface Dose (ESD) at different anatomical locations using Lithium tetraborate doped with manganese (Li2B4O7: Mn), recorded Dose Length Product (DLP) and Dose Area Product (DAP), analyzed Chromosomal Aberration (CA), Micronucleus (MN), gamma-H2AX (gamma-H2AX), and p53ser15 proteins in the blood lymphocytes of patients (n = 267) underwent Computed Tomography (CT), Positron Emission Tomography-CT (PET/CT), and interventional procedures and healthy volunteers (n = 19). The DLP and effective doses obtained from PET/CT procedures were significantly higher (p < 0.05) when compared to CT. Fluoroscopic time and DAP were significantly higher (p < 0.05) in therapeutic compared to diagnostic interventional procedures. All the anatomical locations registered a significant amount of ESD, the ESD obtained from CT and interventional procedures were significantly (p < 0.05) higher when compared to PET/CT. Fluoroscopic time did not correlate with the ESD (eye, head, thyroid, and shoulder; R2 = 0.03). CA frequency after PET/CT was significantly higher (p < 0.001) when compared to CT and interventional procedures. MN frequency was significantly higher in 24-hs (p < 0.001) post-interventional procedure compared to 2-hs. The mean +/- SD of mean fluorescence intensity of gamma-H2AX and p53ser15 obtained from all subjects underwent PET/CT and interventional procedures did not show a significant difference (p > 0.05) between pre- and post-procedure. However, the relative fluorescence intensity of gamma-H2AX and p53ser15 was >1 in 58.5 % and 65.8 % of subjects respectively. Large inter-individual variation and lack of correlation between physical dose and biomarkers suggest the need for robust dosimetry with a large sample size to un- derstand the health effects of low dose radiation.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Statistical analysis of the occupational radiation doses in three different positron emission tomography-computed tomography centers in Egypt
    Ahmed, Ibrahim Elsayed Saad
    Zamzam, Abdulrahman M. M.
    Yassin, Hossam Mahmoud
    WORLD JOURNAL OF NUCLEAR MEDICINE, 2019, 18 (03) : 287 - 292
  • [22] Detection of cardiac metastasis by positron-emission tomography-computed tomography
    Johnson, TRC
    Becker, CR
    Wintersperger, BJ
    Herzog, P
    Lenhard, MS
    Reiser, MF
    CIRCULATION, 2005, 112 (04) : E61 - E62
  • [23] Role of Positron Emission Tomography-Computed Tomography in the Management of Anal Cancer
    Mistrangelo, Massimiliano
    Pelosi, Ettore
    Bello, Marilena
    Ricardi, Umberto
    Milanesi, Enrica
    Cassoni, Paola
    Baccega, Massimo
    Filippini, Claudia
    Racca, Patrizia
    Lesca, Adriana
    Munoz, Fernando H.
    Fora, Gianluca
    Skanjeti, Andrea
    Cravero, Francesca
    Morino, Mario
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (01): : 66 - 72
  • [24] Benign breast lesions detected by positron emission tomography-computed tomography
    Benveniste, Ana P.
    Yang, Wei
    Benveniste, Marcelo F.
    Mawlawi, Osama R.
    Marom, Edith M.
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (06) : 919 - 929
  • [25] Gross tumour delineation on computed tomography and positron emission tomography-computed tomography in oesophageal cancer: A nationwide study
    Nowee, M. E.
    Voncken, F. E. M.
    Kotte, A. N. T. J.
    Goense, L.
    van Rossum, P. S. N.
    van Lier, A. L. H. M. W.
    Heijmink, S. W.
    Aleman, B. M. P.
    Nijkamp, J.
    Meijer, G. J.
    Lips, I. M.
    Braam, P. M.
    Buijsen, J.
    Ceha, H. M.
    Dewit, L.
    Franssen, J. H.
    van Gestel, K.
    Grootenboers, D. A. R. H.
    Intven, M.
    Jansen, E. P. M.
    Kerkmeijer, L. G. W.
    Mul, V. E.
    Muller, K.
    Neelis, K. J.
    Oppedijk, V
    Rozema, T.
    Spruit, P. H.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2019, 14 : 33 - 39
  • [26] Computed Tomography Radiomics for Residual Positron Emission Tomography-Computed Tomography Uptake in Lymph Nodes after Treatment
    Kim, Chu Hyun
    Park, Hyunjin
    Lee, Ho Yun
    Ahn, Joong Hyun
    Lee, Seung Hak
    Sohn, Insuk
    Choi, Joon Young
    Kim, Hong Kwan
    CANCERS, 2020, 12 (12) : 1 - 13
  • [27] Positron Emission Tomography-Computed Tomography in Paraneoplastic Neurologic Disorders Systematic Analysis and Review
    McKeon, Andrew
    Apiwattanakul, Metha
    Lachance, Daniel H.
    Lennon, Vanda A.
    Mandrekar, Jayawant N.
    Boeve, Bradley F.
    Mullan, Brian
    Mokri, Bahram
    Britton, Jeffrey W.
    Drubach, Daniel A.
    Pittock, Sean J.
    ARCHIVES OF NEUROLOGY, 2010, 67 (03) : 322 - 329
  • [28] Positron emission tomography/computed tomography
    Townsend, David W.
    SEMINARS IN NUCLEAR MEDICINE, 2008, 38 (03) : 152 - 166
  • [29] Interventional Positron Emission Tomography/Computed Tomography: State-of-the-Art
    Shyn, Paul B.
    TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 16 (03) : 182 - 190
  • [30] Shifted Helical Computed Tomography to Optimize Cardiac Positron Emission Tomography-Computed Tomography Coregistration: Quantitative Improvement and Limitations
    Johnson, Nils P.
    Pan, Tinsu
    Gould, K. Lance
    MOLECULAR IMAGING, 2010, 9 (05) : 256 - 267