StaticCodeCT: single coded aperture tensorial X-ray CT

被引:8
|
作者
Cuadros, Angela P. [1 ]
Ma, Xu [2 ]
Restrepo, Carlos M. [1 ]
Arce, Gonzalo R. [1 ]
机构
[1] Univ Delaware, Dept Elect & Comp Engn, Newark, DE 19716 USA
[2] Beijing Inst Technol, Sch Opt & Photon, Key Lab Photoelect Imaging Technol & Syst, Minist Educ China, Beijing 100081, Peoples R China
基金
美国国家科学基金会;
关键词
IMAGE-RECONSTRUCTION; COMPUTED-TOMOGRAPHY; OPTIMIZATION; DECOMPOSITION; QUALITY;
D O I
10.1364/OE.427382
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Coded aperture X-ray CT (CAXCT) is a new low-dose imaging technology that promises far-reaching benefits in industrial and clinical applications. It places various coded apertures (CA) at a time in front of the X-ray source to partially block the radiation. The ill-posed inverse reconstruction problem is then solved using 11-norm-based iterative reconstruction methods. Unfortunately, to attain high-quality reconstructions, the CA patterns must change in concert with the view-angles making the implementation impractical. This paper proposes a simple yet radically different approach to CAXCT, which is coined StaticCodeCT, that uses a single-static CA in the CT gantry, thus making the imaging system amenable for practical implementations. Rather than using conventional compressed sensing algorithms for recovery, we introduce a new reconstruction framework for StaticCodeCT. Namely, we synthesize the missing measurements using low-rank tensor completion principles that exploit the multi-dimensional data correlation and low-rank nature of a 3-way tensor formed by stacking the 2D coded CT projections. Then, we use the FDK algorithm to recover the 3D object. Computational experiments using experimental projection measurements exhibit up to 10% gains in the normalized root mean square distance of the reconstruction using the proposed method compared with those attained by alternative low-dose systems. (C) 2021 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:20558 / 20576
页数:19
相关论文
共 50 条
  • [1] Coded Aperture Compressive X-ray Spectral CT
    Cuadros, Angela P.
    Arce, Gonzalo R.
    2017 INTERNATIONAL CONFERENCE ON SAMPLING THEORY AND APPLICATIONS (SAMPTA), 2017, : 548 - 551
  • [2] Coded Aperture X-ray Scatter Tomography
    Holmgren, Andrew D.
    MacCabe, Kenneth P.
    Tornai, Martin P.
    Brady, David J.
    COMPUTATIONAL IMAGING XII, 2014, 9020
  • [3] X-ray phase contrast imaging using single absorption coded aperture
    Krejci, Frantisek
    Jakubek, Jan
    Kroupa, Martin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 633 : S181 - S184
  • [4] XCAT: The JANUS X-Ray Coded Aperture Telescope
    Penn State University, Dept. of Astronomy and Astrophysics, University Park, PA 16802, United States
    不详
    不详
    不详
    不详
    不详
    Proc SPIE Int Soc Opt Eng,
  • [5] Coded Aperture Design in Compressive X-Ray Tomography
    Cuadros, Angela P.
    Arce, Gonzalo R.
    Arguello, Henry
    2014 IEEE GLOBAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING (GLOBALSIP), 2014, : 656 - 659
  • [6] XCAT: The JANUS X-Ray Coded Aperture Telescope
    Falcone, A. D.
    Burrows, D. N.
    Barthelmy, S.
    Chang, W.
    Fox, D.
    Fredley, J.
    Gehrels, N.
    Kelly, M.
    Klar, R.
    Palmer, D.
    Persyn, S.
    Reichard, K.
    Roming, P.
    Seifert, E.
    Smith, R. W. M.
    Wood, P.
    Zugger, M.
    SPACE TELESCOPES AND INSTRUMENTATION 2010: ULTRAVIOLET TO GAMMA RAY, 2010, 7732
  • [7] Time-coded aperture for x-ray imaging
    Ching, Daniel
    Aslan, Selin
    Nikitin, Viktor
    Gursoy, Doga
    OPTICS LETTERS, 2019, 44 (11) : 2803 - 2806
  • [8] Coded aperture optimization for compressive X-ray tomosynthesis
    Cuadros, Angela P.
    Peitsch, Christopher
    Arguello, Henry
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2015, 23 (25): : 32788 - 32802
  • [9] Optimization of Coded Aperture in Compressive X-ray Tomography
    Mao, Tianyi
    Cuadros, Angela P.
    Ma, Xu
    He, Weiji
    Chen, Qian
    Arce, Gonzalo R.
    APPLICATIONS OF DIGITAL IMAGE PROCESSING XLI, 2018, 10752
  • [10] Experimental demonstration and optimization of X-ray StaticCodeCT
    Cuadros, Angela P.
    Liu, Xiaokang
    Parsons, Paul E.
    Ma, Xu
    Arce, Gonzalo R.