Loose intra-articular body following anterior cruciate ligament reconstruction

被引:18
|
作者
Cossey, AJ [1 ]
Paterson, RS [1 ]
Orth, FA [1 ]
机构
[1] SportsMed SA, Stepney, SA 5069, Australia
来源
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY | 2005年 / 21卷 / 03期
关键词
loose body; ACL reconstruction; bioabsorbable fixation;
D O I
10.1016/j.arthro.2004.11.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report a case of intra-articular fracture of a bioabsorbable fixation device from the femoral tunnel in an anterior cruciate ligament reconstruction using a bone-tendon-bone graft. Thirteen months after successful reconstruction surgery, the patient experienced episodes of locking and medial joint pain. There was no history of trauma and no symptoms of instability or swelling. On revision arthroscopy, a fractured tip of a bioabsorbable RIGIDfix cross pin (Mitek, Westwood, MA) was identified in the medial compartment of the knee. There was a broad area of chondral erosion affecting the medial femoral condyle and a small defect to the medial tibial plateau where the loose body had been lodged. The bone-tendon-bone graft was intact without disruption. After arthroscopy, the patient was symptom free for 3 weeks but then developed further symptoms of locking. Magnetic resonance imaging showed another loose body within the knee. A repeat arthroscopy was performed 6 weeks after the earlier procedure and another piece of the polylactic acid RIGIDfix cross pin was removed, this time from the lateral gutter. This case raises concern about the potential for breakage and resultant loose body formation that may occur after bioabsorbable cross-pin fixation and, particularly, the associated chondral damage that can occur if early intervention is not conducted.
引用
收藏
页码:348 / 350
页数:3
相关论文
共 50 条
  • [21] Intra-articular pull out of an interference screw after anterior cruciate ligament reconstruction
    Moonot, P.
    Allen, P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (09) : 862 - 864
  • [22] Intra-articular pull out of an interference screw after anterior cruciate ligament reconstruction
    Moonot, P.
    Allen, P.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2006, 14 (10) : 1004 - 1006
  • [23] Intra-articular pull out of an interference screw after anterior cruciate ligament reconstruction
    P. Moonot
    P. Allen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 862 - 864
  • [24] Intra-articular pull out of an interference screw after anterior cruciate ligament reconstruction
    P. Moonot
    P. Allen
    Knee Surgery, Sports Traumatology, Arthroscopy, 2006, 14 : 1004 - 1006
  • [25] Assessment of an Intra-Articular Drain in Arthroscopy-Assisted Anterior Cruciate Ligament Reconstruction
    Shamim, Sharib
    Kushwaha, Sudhir S.
    Shantanu, Kumar
    Maurya, Garima
    Arshad, Iram
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (08)
  • [26] Factors Associated With an Intra-articular Infection After Anterior Cruciate Ligament Reconstruction: Letter to the Editor
    Yang, Deyong
    Shu, Li
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2022, 50 (13): : NP55 - NP55
  • [27] Intra-articular mechanical blocks and full extension in patients undergoing anterior cruciate ligament reconstruction
    Jomha, NM
    Clingeleffer, A
    Pinczewski, L
    ARTHROSCOPY, 2000, 16 (02): : 156 - 159
  • [28] Effect of muscle preserved on tendon graft on intra-articular healing in anterior cruciate ligament reconstruction
    Sun, Lei
    Hou, Cunqiang
    Wu, Bo
    Tian, Min
    Zhou, Xianhua
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2013, 21 (08) : 1862 - 1868
  • [29] Effect of muscle preserved on tendon graft on intra-articular healing in anterior cruciate ligament reconstruction
    Lei Sun
    Cunqiang Hou
    Bo Wu
    Min Tian
    Xianhua Zhou
    Knee Surgery, Sports Traumatology, Arthroscopy, 2013, 21 : 1862 - 1868
  • [30] Loose body following cross-pin fixation for anterior cruciate ligament reconstruction
    Boden R.A.
    Razak A.
    Hussain S.M.A.
    McLoughlin S.J.
    Journal of Orthopaedics and Traumatology, 2013, 14 (2) : 155 - 157