Analysis of volatile organic compounds in air with a micro ion trap mass analyzer

被引:32
|
作者
Moxom, J [1 ]
Reilly, PTA [1 ]
Whitten, WB [1 ]
Ramsey, M [1 ]
机构
[1] Oak Ridge Natl Lab, Oak Ridge, TN 37831 USA
关键词
D O I
10.1021/ac034043k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Analysis of several volatile organic compounds in air has been demonstrated with a micro ion trap mass analyzer equipped with a semipermeable membrane sampling inlet MS/MS of selected compounds was also shown to be feasible with the miniature ion trap and could be used to improve sensitivity by reducing background noise.
引用
收藏
页码:3739 / 3743
页数:5
相关论文
共 50 条
  • [31] Calibration of mass selective detector in non-target analysis of volatile organic compounds in the air
    Arh, Gregor
    Klasinc, Leo
    Veber, Marjan
    Pompe, Matevz
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (11) : 1538 - 1543
  • [32] Development of quadrupole ion trap methods for determination of atmospheric volatile organic compounds.
    Shepson, PB
    Hurst, JM
    Barket, DJ
    Colorado, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1999, 217 : U136 - U136
  • [33] Miniaturized Linear Wire Ion Trap Mass Analyzer
    Wu, Qinghao
    Li, Ailin
    Tian, Yuan
    Zare, Richard N.
    Austin, Daniel E.
    ANALYTICAL CHEMISTRY, 2016, 88 (15) : 7800 - 7806
  • [34] Biomolecular dual-ion-trap mass analyzer
    Hsu, Yun-Fei
    Lin, Jung-Lee
    Chu, Ming-Lee
    Chen, Chung-Hsuan
    ANALYST, 2013, 138 (17) : 4823 - 4829
  • [35] Ion Trap Array Mass Analyzer: Structure and Performance
    Li, Xiaoxu
    Jiang, Gongyu
    Luo, Chan
    Xu, Fuxing
    Wang, Yuanyuan
    Ding, Li
    Ding, Chuan-Fan
    ANALYTICAL CHEMISTRY, 2009, 81 (12) : 4840 - 4846
  • [36] Ion trap array mass analyzer: Structure and performance
    Laser Chemistry Institute, Department of Chemistry, Fudan University, Shanghai 200433, China
    不详
    不详
    Anal. Chem., 1600, 12 (4840-4846):
  • [37] Design and performance of the halo ion trap mass analyzer
    Wang, Miao
    Austin, Daniel E.
    Tolley, Samuel E.
    Hansen, Brett J.
    Hawkins, Aaron R.
    Lee, Edgar D.
    Lee, Milton L.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 275 - 275
  • [38] Optimisation of purge-and-trap gas chromatography-mass spectrometry analysis of volatile organic compounds in water
    Fernández-Villarrenaga, V
    López-Mahía, P
    Muniategui-Lorenzo, S
    Prada-Rodríguez, D
    CHEMIA ANALITYCZNA, 2006, 51 (01): : 89 - 98
  • [39] High surface area membrane introduction mass spectrometry for analysis of volatile and semi-volatile organic compounds in air
    Riter, LS
    Takáts, Z
    Charles, L
    Cooks, RG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (17) : 1520 - 1524
  • [40] Analysis of organometallic compounds using ion trap mass spectrometry
    Dyson, PJ
    McIndoe, JS