Automated on-line dialysis and liquid chromatography of methylenedioxylated amphetamines in plasma and serum samples

被引:13
|
作者
Sadeghipour, F [1 ]
Veuthey, JL [1 ]
机构
[1] Univ Geneva, Lab Chim Analyt Pharmaceut, CH-1211 Geneva 4, Switzerland
关键词
on-line dialysis; reversed-phase liquid chromatography; methylenedioxylated amphetamines;
D O I
10.1016/S0731-7085(98)00012-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An automated on-line dialysis coupled to a trace enrichment method has been developed for the separation and quantification of four methylenedioxylated amphetamines in serum and plasma, using liquid chromatography coupled to a fluorimetric detector. The on-line dialysis method was optimized and validated on fresh human serum and plasma samples. This sample preparation method allowed the quantification of methylenedioxylated amphetamines in serum or plasma, at concentrations as low as ca. 10 ng ml(-1), with good repeatability, reproducibility and accuracy. The automated on-line dialysis method took less than 30 min. This method was applied to seven toxicological cases and results showed that the concentration of methylenedioxylated amphetamines in blood was in the range of 20-484 ng ml(-1). (C) 1997 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:801 / 810
页数:10
相关论文
共 50 条
  • [41] Automated on-line liquid-liquid extraction system for temporal mass spectrometric analysis of dynamic samples
    Hsieh, Kai-Ta
    Liu, Pei-Han
    Urban, Pawel L.
    ANALYTICA CHIMICA ACTA, 2015, 894 : 35 - 43
  • [42] On-line dialysis as a sample preparation technique for ion chromatography
    De Borba, BM
    Brewer, JM
    Camarda, J
    JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) : 59 - 65
  • [43] Perspectives of on-line coupled liquid chromatography–gas chromatography
    Tuulia Hyötyläinen
    Marja-Liisa Riekkola
    Analytical and Bioanalytical Chemistry, 2004, 378 : 1936 - 1938
  • [44] On-line coupled liquid chromatography-gas chromatography
    Hyötyläinen, T
    Riekkola, ML
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 357 - 384
  • [45] Coupling of sequential injection with liquid chromatography for the automated derivatization and on-line determination of amino acids
    Zacharis, Constantinos K.
    Theodoridis, Georgios A.
    Voulgaropoulos, Anastasios N.
    TALANTA, 2006, 69 (04) : 841 - 847
  • [46] Automated method for the determination of a new matrix metalloproteinase inhibitor in ovine plasma and serum by coupling of restricted access material for on-line sample clean-up to liquid chromatography
    Chiap, P
    Piette, M
    Evrard, B
    Frankenne, F
    Christiaens, B
    Piel, G
    Cataldo, D
    Foidart, JM
    Delattre, L
    Crommen, J
    Hubert, P
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 817 (01): : 109 - 117
  • [47] Automated on-line liquid chromatography-photodiode array-mass spectrometr method with dilution line for the determination of bisphenol A and 4-octylphenol in serum
    Liu, Min
    Hashi, Yuki
    Pan, Fengyun
    Yao, Jianguo
    Song, Guanqun
    Lin, Jin-Ming
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1133 (1-2) : 142 - 148
  • [48] An on-line multidimensional liquid chromatography strategy for coupling serum glycomic and glycoproteomic analytical data
    Doherty, Margaret
    Bones, Jonathan
    Rudd, Pauline M.
    GLYCOBIOLOGY, 2013, 23 (11) : 1362 - 1362
  • [49] Recent advances in on-line multidimensional liquid chromatography
    Malerod, Helle
    Lundanes, Elsa
    Greibrokk, Tyge
    ANALYTICAL METHODS, 2010, 2 (02) : 110 - 122
  • [50] On-line coupling of liquid chromatography to biological assays
    Lutz, ESM
    Oosterkamp, AJ