Early mortality from off-pump and on-pump coronary bypass surgery in Canada: A comparison of the STS and the EuroSCORE risk prediction algorithms

被引:19
|
作者
Farrokhyar, Forough
Wang, Xiaoyin
Kent, Rosanne
Lamy, Andre
机构
[1] McMaster Univ, Dept Surg, Hamilton, ON L8L 3Z5, Canada
[2] McMaster Univ, Dept Epidemiol & Biostat, Hamilton, ON, Canada
关键词
CABG; cardiopulmonary bypass; mortality; off-pump; on-pump; risk prediction; surgery;
D O I
10.1016/S0828-282X(07)70843-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVE: Early mortality from off-pump and on-pump coronary artery bypass graft(CABG) surgery was assessed and compared with two widely used risk algorithms for CABG: The Society of Thoracic Surgeons(STS) and the European System for Cardiac Operative Risk Evaluation (EuroSCORE). METHOD: From March 12, 2001, to December 31, 2002, 1657 con, secutive patients were treated with off-pump CABG and 1693 consecutive patients were treated with on-pump CABG. The predicted risk of mortality scores for the STS and EuroSCORE models were calculated. The predictive accuracy for early mortality was assessed by comparing the observed and expected mortalities for equal sized quantiles of risk using the Hosmer-Lemeshow goodness-of-fit test. The discriminatory power of the models was evaluated by calculating the area under the receiver operating characteristic (ROC) curves. RESULTS: The observed postoperative mortality was 1.8% (95% CI 1.3% to 2.4%) for off-pump CABG and 1.5% (95% CI 1.1% to 2.1%) for on-pump CABG. For both on-pump and off-pump CABG surgery, the Hosmer-Lemeshow goodness-of-fit test indicated good accuracy. The area under the ROC curve was 0.81 (95% CI 0.73 to 0.90) for the STS and 0.79 (95% CI 0.71 to 0.88) for EuroSCORE in off-pump CABG (P=0.567). The area under the ROC curve was 0.82 (95% CI 0.73 to 0.91) for STS and 0.81 (95% CI 0.71 to 0.90) for EuroSCORE in on-pump CABG (P=0.616). The STS-predicted risk of stroke, prolonged ventilation and renal failure were similar to the observed data, with relatively good discriminatory powers for both off-pump and on-pump CABG. CONCLUSION: Both the STS and EuroSCORE risk algorithms are good predictors of early mortality from off-pump or on-pump CABG surgery. However, the generalizability of these results in the Canadian context would require a broader sampling of Canadian centres, including ones that provide both on-pump and off-pump CABG.
引用
收藏
页码:879 / 883
页数:5
相关论文
共 50 条
  • [21] Comparison of inflammatory response during on-pump and off-pump coronary artery bypass surgery
    Rimmele, Thomas
    Venkataraman, Ramesh
    Madden, Nicholas J.
    Elder, Michele M.
    Wei, Lawrence M.
    Pellegrini, Ronald V.
    Kellum, John A.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2010, 33 (03): : 131 - 138
  • [22] Comparison of Platelet Mass Index in On-Pump and Off-Pump Coronary Artery Bypass Surgery
    Gunday, Murat
    Ciftci, Ozgur
    HEART SURGERY FORUM, 2020, 23 (02): : E154 - E159
  • [23] Risk of retinal microembolism after off-pump and on-pump coronary artery bypass surgery
    Rainio, A.
    Hautala, N.
    Pelkonen, O.
    Palosaari, T.
    Heikkinen, J.
    Mosorin, M.
    Lahtinen, J.
    Taskinen, P.
    Anttila, V.
    Surcel, H. -M.
    Lepojarvi, M.
    Juvonen, T.
    Biancari, F.
    JOURNAL OF CARDIOVASCULAR SURGERY, 2007, 48 (06): : 773 - 779
  • [24] Comparison of cerebral embolization during off-pump and on-pump coronary artery bypass surgery
    Lund, C
    Hol, PK
    Lundblad, R
    Fosse, E
    Sundet, K
    Tennoe, B
    Brucher, R
    Russell, D
    ANNALS OF THORACIC SURGERY, 2003, 76 (03): : 765 - 770
  • [25] Isoprostanes and oxidative stress in off-pump and on-pump coronary bypass surgery
    Cavalca, V
    Sisillo, E
    Veglia, F
    Tremoli, E
    Cighetti, G
    Salvi, L
    Sola, A
    Mussoni, L
    Biglioli, P
    Folco, G
    Sala, A
    Parolari, A
    ANNALS OF THORACIC SURGERY, 2006, 81 (02): : 562 - 567
  • [26] Off-pump and on-pump coronary artery bypass surgery: time to move on
    Raja, SG
    CHINESE MEDICAL JOURNAL, 2004, 117 (06) : 959 - 959
  • [27] Off-pump and on-pump coronary artery bypass surgery:time to move on
    Shahzad G Raja
    中华医学杂志(英文版), 2004, (06) : 159 - 159
  • [28] Off-pump and on-pump coronary artery bypass surgery:time to move on
    Shahzad G Raja
    ChineseMedicalJournal, 2004, (06)
  • [29] Off-pump versus on-pump coronary bypass -: Comparison of patient characteristics and early outcomes
    Järvinen, O
    Laurikka, J
    Tarkka, MR
    JOURNAL OF CARDIOVASCULAR SURGERY, 2003, 44 (02): : 167 - 172
  • [30] Mortality and Readmissions After On-Pump Versus Off-Pump Redo Coronary Artery Bypass Surgery
    Aranda-Michel, Edgar
    Bianco, Valentino
    Kilic, Arman
    Gleason, Thomas G.
    Navid, Forozan
    Sultan, Ibrahim
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2020, 21 (07) : 821 - 825