Regularized Three-Dimensional Generative Adversarial Nets for Unsupervised Metal Artifact Reduction in Head and Neck CT Images

被引:23
|
作者
Nakao, Megumi [1 ]
Imanishi, Keiho [2 ]
Ueda, Nobuhiro [3 ]
Imai, Yuichiro [4 ]
Kirita, Tadaaki [3 ]
Matsuda, Tetsuya [1 ]
机构
[1] Kyoto Univ, Grad Sch Informat, Kyoto 6068501, Japan
[2] E Growth Co Ltd, Kyoto 6048006, Japan
[3] Nara Med Univ, Dept Oral & Maxillofacial Surg, Kashihara, Nara 6340813, Japan
[4] Rakuwakai Otowa Hosp, Dept Oral & Maxillofacial Surg, Kyoto 6078062, Japan
关键词
Computed tomography; Metals; Three-dimensional displays; Training; Databases; Surgery; Biomedical imaging; generative adversarial network; metal artifact reduction; unsupervised image translation; CONVOLUTIONAL NEURAL-NETWORK; RAY COMPUTED-TOMOGRAPHY;
D O I
10.1109/ACCESS.2020.3002090
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The reduction of metal artifacts in computed tomography (CT) images, specifically for strong artifacts generated from multiple metal objects, is a challenging issue in medical imaging research. Although there have been some studies on supervised metal artifact reduction through the learning of synthesized artifacts, it is difficult for simulated artifacts to cover the complexity of the real physical phenomena that may be observed in X-ray propagation. In this paper, we introduce metal artifact reduction methods based on an unsupervised volume-to-volume translation learned from clinical CT images. We construct three-dimensional adversarial nets with a regularized loss function designed for metal artifacts from multiple dental fillings. The results of experiments using a CT volume database of 361 patients demonstrate that the proposed framework has an outstanding capacity to reduce strong artifacts and to recover underlying missing voxels, while preserving the anatomical features of soft tissues and tooth structures from the original images.
引用
收藏
页码:109453 / 109465
页数:13
相关论文
共 50 条
  • [41] Motion Artifact Reduction Using U-Net Model with Three-Dimensional Simulation-Based Datasets for Brain Magnetic Resonance Images
    Kang, Seong-Hyeon
    Lee, Youngjin
    BIOENGINEERING-BASEL, 2024, 11 (03):
  • [42] Deep learning-based metal artifact reduction using cycle-consistent adversarial network for intensity-modulated head and neck radiation therapy treatment planning
    Koike, Yuhei
    Anetai, Yusuke
    Takegawa, Hideki
    Ohira, Shingo
    Nakamura, Satoaki
    Tanigawa, Noboru
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 8 - 14
  • [43] A three-dimensional virtual model of the head generated from digitalized CT or MR images for anatomical-radiological and neurosurgical evaluations
    Juanes, JA
    Espinel, JL
    Velasco, MJ
    Zoreda, JL
    Riesco, JM
    Carmena, JJ
    Blanco, E
    Marcos, J
    Vazquez, R
    JOURNAL OF NEURORADIOLOGY, 1996, 23 (04) : 211 - 216
  • [44] Improvement in image quality of noncontrast head images in multidetector-row CT by volume helical scanning with a three-dimensional denoising filter
    Sasaki T.
    Sasaki M.
    Hanari T.
    Gakumazawa H.
    Noshi Y.
    Okumura M.
    Radiation Medicine, 2007, 25 (7): : 368 - 372
  • [45] Set-up errors in head and neck cancer patients treated with intensity modulated radiation therapy: Quantitative comparison between three-dimensional cone-beam CT and two-dimensional kilovoltage images
    Ciardo, Delia
    Alterio, Daniela
    Jereczek-Fossa, Barbara Alicja
    Riboldi, Marco
    Zerini, Dario
    Santoro, Luigi
    Preve, Eleonora
    Rondi, Elena
    Comi, Stefania
    Serafini, Flavia
    Laudati, Antonio
    Ansarin, Mohssen
    Preda, Lorenzo
    Baroni, Guido
    Orecchia, Roberto
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1015 - 1021
  • [46] Three-dimensional shape completion using deep convolutional neural networks: Application to truncation compensation and metal artifact reduction in PET/MRI attenuation correction
    Arabi, Hossein
    Zaidi, Habib
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [47] Image Quality of Commercial CT Metal Artifact Reduction Algorithms and a Novel In-House Algorithm for Head and Neck (H&N) Cancer and the Dosimetric Implications On Proton Therapy
    Branco, D.
    Kry, S.
    Taylor, P.
    Zhang, X.
    Rong, J.
    Frank, S.
    Followill, D.
    MEDICAL PHYSICS, 2020, 47 (06) : E790 - E790
  • [48] Three-dimensional parametric mapping in quantitative micro-CT imaging of post-surgery femoral head-neck samples: preliminary results
    Giannotti, Stefano
    Bottai, Vanna
    Panetta, Daniele
    De Paola, Gaia
    Tripodi, Maria
    Citarelli, Carmine
    Dell'Osso, Giacomo
    Lazzerini, Ilaria
    Salvadori, Piero Antonio
    Guido, Giulio
    CLINICAL CASES IN MINERAL AND BONE METABOLISM, 2015, 12 (03) : 243 - 246
  • [49] Three-dimensional margin assessment in head and neck malignancies using a submillimetric 18F-FDG PET/CT, results of an ongoing clinical trial
    Debacker, Jens
    Creytens, David
    Brochez, Lieve
    Dasseler, Yves
    Deron, Philippe
    Dhooghe, Nicolas
    Dochy, Frederick
    Keereman, Vincent
    Schelfhout, Vanessa
    Tomassen, Peter
    Van Holen, Roel
    Vanhove, Christian
    Huvenne, Wouter
    ORAL ONCOLOGY, 2021, 118
  • [50] High-Resolution 18F-FDG PET/CT for Assessing Three-Dimensional Intraoperative Margins Status in Malignancies of the Head and Neck, a Proof-of-Concept
    Debacker, Jens M.
    Schelfhout, Vanessa
    Brochez, Lieve
    Creytens, David
    D'Asseler, Yves
    Deron, Philippe
    Keereman, Vincent
    Van de Vijver, Koen
    Vanhove, Christian
    Huvenne, Wouter
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (16)