Removal of high concentration of NH3 and coexistent H2S by biological activated carbon (BAC) biotrickling filter

被引:90
|
作者
Chung, YC
Lin, YY
Tseng, CP [1 ]
机构
[1] Natl Chiao Tung Univ, Dept Biol Sci & Technol, Hsinchu 300, Taiwan
[2] China Inst Technol, Dept Biol Sci & Technol, Taipei 115, Taiwan
关键词
biotrickling filter; activated carbon; hydrogen sulfide; ammonia;
D O I
10.1016/j.biortech.2005.01.003
中图分类号
S2 [农业工程];
学科分类号
0828 ;
摘要
High efficiency of NH3 and H2S removal from waste gases was achieved by the biotrickling filter. Granular activated carbon (GAC), inoculated with Arthrobacter oxydans CH8 for NH3 removal and Pseudomonas putida CH11 for H2S removal, was used as packing material. Under conditions in which 100% H2S was removed, extensive tests to eliminate high concentrations of NH3 emission-including removal characteristics, removal efficiency, and removal capacity of the system-were performed. The results of the Bed Depth Service Time (BDST) experiment suggested that physical adsorption of NH3 gas by GAC was responsible for the first 10 days, after which NH3 gas was biodegraded by inoculated microorganisms. The dynamic steady state between physical adsorption and biodegradation was about two weeks. After the system achieved equilibrium, the BAC biotrickling filter exhibited high adaptation to shock loading, elevated temperature, and flow rate. Greater than 96% removal efficiency for NH3 was achieved during the 140-day operating period when inlet H2S loading was maintained at 6.25 g-S/m(3)/h. During the operating period, the pH varied between 6.5 and 8.0 after the physical adsorption stage, and no acidification or alkalinity was observed. The results also demonstrated that NH3 removal was not affected by the coexistence of H2S while gas retention time was the key factor in system performance. The retention time of at least 65 s is required to obtain a greater than 95% NH3 removal efficiency. The critical loading of NH3 for the system was 4.2 g-N/m(3)/h, and the maximal loading was 16.2 g-N/m(3)/h. The results of this study could be used as a guide for further design and operation of industrial-scale systems. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1812 / 1820
页数:9
相关论文
共 50 条
  • [21] NH3 and H2S Removal Characteristics on Spherical Carbons: Synergistic Effect between Activated Carbon and Zeolite Composites
    Ye, Shu
    Oh, Won-Chun
    KOREAN JOURNAL OF MATERIALS RESEARCH, 2016, 26 (12): : 726 - 732
  • [22] Treatment of H2S using a horizontal biotrickling filter based on biological activated carbon: reactor setup and performance evaluation
    Huiqi Duan
    Lawrence Choon Chiaw Koe
    Rong Yan
    Applied Microbiology and Biotechnology, 2005, 67 : 143 - 149
  • [23] High-concentration H2S treatment by pilot-scale biotrickling filter
    Jiang, Liying
    Chen, Jianmeng
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [24] Performance evaluation of H2S and NH3 removal by biological trickling filter reactors with various fillers under heterotrophic conditions
    Huan, Chenchen
    Wang, Zhenhong
    Tong, Xinyu
    Zeng, Yong
    Liu, Yang
    Cheng, Yapeng
    Lyu, Qingyang
    Yan, Zhiying
    Tian, Xueping
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 900
  • [25] Biotrickling Filter Optimization Measures and it Impact on the Removal Efficiency for H2S
    Ge Jie
    Zhang Chengzhong
    ICOD 2010: PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON OPTIMIZATION DESIGN, 2010, : 91 - 94
  • [26] Modifying Agent Concentrations of Ceramic in H2S Removal Biotrickling filter
    Ge Jie
    Zhang, Cheng-zhong
    Li, Shanshan
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [27] Transient-state biodegradation behavior of a horizontal biotrickling filter in co-treating gaseous H2S and NH3
    Xia Jiang
    Rong Yan
    Joo Hwa Tay
    Applied Microbiology and Biotechnology, 2009, 81 : 969 - 975
  • [28] Removal of H2S in biogas using biotrickling filter: Recent development
    Hao Huynh Nhut
    Van Le Thi Thanh
    Luu Tran Le
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 144 : 297 - 309
  • [29] Transient-state biodegradation behavior of a horizontal biotrickling filter in co-treating gaseous H2S and NH3
    Jiang, Xia
    Yan, Rong
    Tay, Joo Hwa
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 2009, 81 (05) : 969 - 975
  • [30] Electrodeposition of copper and iron oxides on to activated carbon fibre cloths:: Application to H2S and NH3 removal from air
    Subrenat, A.
    Le Leuch, L. M.
    Le Cloirec, P.
    ENVIRONMENTAL TECHNOLOGY, 2008, 29 (09) : 993 - 1000