Fully packaged non-enzymatic glucose micro-sensor for in-vivo and continuously monitoring system applications

被引:0
|
作者
Park, Dae J. [1 ]
Lee, Yi J. [1 ]
Park, Jae Y. [1 ]
机构
[1] Kwangwoon Univ, Dept Elect Engn, Seoul 139701, South Korea
关键词
D O I
10.1109/ICSENS.2007.4388339
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this paper, fully packaged non-enzymatic glucose micro-sensor with Nafion membrane was designed and fabricated on silicon substrate for in-vivo applications. Working and counter electrodes of the micro-sensors were formed with electroplated mesoporous platinum and its reference electrode was patterned with screen-printed Ag/AgCl. The fabricated micro-sensors with plane Pt WE/CE, mesoporous Pt WE, and mesoporous Pt WE/CE have different sensitivities of 0.009 mu A mM(-1) cm(-2), 5.46 mu A mM(-1) cm(-2), and 7.75 mu A mM(-1) cm(-2) in glucose solution, respectively. The fully packaged micro-sensor with Nafion membrane has a sensitivity of 0.36 mu A mM(-1) cm(-2) and excellent linearity in the glucose concentration ranged from 0 mM to 30 mM. The biocompatible Nafion membrane was utilized to avoid not only reactivation of ascorbic acid and acetaminophen but also the electrode fouling by proteins in the blood serum for in-vivo and continuously monitoring systems.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [1] Long-term stabled non-enzymatic glucose sensor for continuously monitoring system applications
    Park, Dae-Joon
    Lee, Yi-Jae
    Park, Jae-Yeong
    Kim, Dae Heum
    [J]. 2008 3RD IEEE INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEMS, VOLS 1-3, 2008, : 706 - +
  • [2] Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon
    Lee, Yi-Jae
    Park, Dae-Joon
    Park, Jae-Yeong
    Kim, Younghun
    [J]. SENSORS, 2008, 8 (10): : 6154 - 6164
  • [3] Non-enzymatic continuous glucose monitoring system
    [J]. Song, In-Hyouk (in-hyouk.song@txstate.edu), 2018, John Wiley and Sons Inc (13):
  • [4] Non-enzymatic continuous glucose monitoring system
    Moore, Sean
    You, Byoung Hee
    Kim, Namwon
    Park, Taehyun
    Song, In-Hyouk
    [J]. MICRO & NANO LETTERS, 2018, 13 (08): : 1079 - 1084
  • [5] Wearable, robust, non-enzymatic continuous glucose monitoring system and its in vivo investigation
    Yoon, Hyosang
    Xuan, Xing
    Jeong, Sungkwan
    Park, Jae Y.
    [J]. BIOSENSORS & BIOELECTRONICS, 2018, 117 : 267 - 275
  • [6] A wearable non-enzymatic sensor for continuous monitoring of glucose in human sweat
    Chen, Yuhua
    Sun, Yanghan
    Li, Yi
    Wen, Zhuo
    Peng, Xinyu
    He, Yuanke
    Hou, Yuanfang
    Fan, Jingchuan
    Zang, Guangchao
    Zhang, Yuchan
    [J]. TALANTA, 2024, 278
  • [7] Flexible hydrogel non-enzymatic QCM sensor for continuous glucose monitoring
    Liu, Na
    Xiang, Xueping
    Sun, Mengmeng
    Li, Peiyi
    Qin, Haiyang
    Liu, Huan
    Zhou, Yuanyuan
    Wang, Lejia
    Wu, Lidong
    Zhu, Jun
    [J]. Biosensors and Bioelectronics: X, 2022, 10
  • [8] Stability of non-enzymatic glucose sensor based on platinum micro-/nanostructures
    Urban, S.
    Unmuessig, T.
    Daubinger, P.
    Kieninger, J.
    Urban, G.
    [J]. EUROSENSORS 2015, 2015, 120 : 1145 - 1148
  • [9] Review-In Vivo and In Vitro Microneedle Based Enzymatic and Non-Enzymatic Continuous Glucose Monitoring Biosensors
    Chinnadayyala, Somasekhar R.
    Park, Ki Deok
    Cho, Sungbo
    [J]. ECS JOURNAL OF SOLID STATE SCIENCE AND TECHNOLOGY, 2018, 7 (07) : Q3159 - Q3171
  • [10] Applications of Advanced Materials for Non-Enzymatic Glucose Monitoring: From Invasive to the Wearable Device
    Golsanamlou, Zahra
    Mahmoudpour, Mansour
    Soleymani, Jafar
    Jouyban, Abolghasem
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2021, 53 (05) : 1116 - 1131