Fabrication and Optimization of a Nanoporous Platinum Electrode and a Non-enzymatic Glucose Micro-sensor on Silicon

被引:48
|
作者
Lee, Yi-Jae [1 ]
Park, Dae-Joon [1 ]
Park, Jae-Yeong [1 ]
Kim, Younghun [2 ]
机构
[1] Kwangwoon Univ, Dept Elect Engn, Seoul 139701, South Korea
[2] Kwangwoon Univ, Dept Chem Engn, Seoul 139701, South Korea
来源
SENSORS | 2008年 / 8卷 / 10期
关键词
Nanoporous platinum; silicon CMOS integrable; non-enzymatic; glucose sensor;
D O I
10.3390/s8106154
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, optimal conditions for fabrication of nanoporous platinum (Pt) were investigated in order to use it as a sensitive sensing electrode for silicon CMOS integrable non-enzymatic glucose micro-sensor applications. Applied charges, voltages, and temperatures were varied during the electroplating of Pt into the formed nonionic surfactant C16EO8 nano-scaled molds in order to fabricate nanoporous Pt electrodes with large surface roughness factor (RF), uniformity, and reproducibility. The fabricated nanoporous Pt electrodes were characterized using atomic force microscopy (AFM) and electrochemical cyclic voltammograms. Optimal electroplating conditions were determined to be an applied charge of 35 mC/mm(2), a voltage of -0.12 V, and a temperature of 25 degrees C, respectively. The optimized nanoporous Pt electrode had an electrochemical RF of 375 and excellent reproducibility. The optimized nanoporous Pt electrode was applied to fabricate non-enzymatic glucose micro-sensor with three electrode systems. The fabricated sensor had a size of 3 mm x 3 mm, air gap of 10 mu m, working electrode (WE) area of 4.4 mm(2), and sensitivity of 37.5 mu A.L/mmol.cm(2). In addition, it showed large detection range from 0.05 to 30 mmolL(-1) and stable recovery responsive to the step changes in glucose concentration.
引用
收藏
页码:6154 / 6164
页数:11
相关论文
共 50 条
  • [1] Stability of non-enzymatic glucose sensor based on platinum micro-/nanostructures
    Urban, S.
    Unmuessig, T.
    Daubinger, P.
    Kieninger, J.
    Urban, G.
    [J]. EUROSENSORS 2015, 2015, 120 : 1145 - 1148
  • [2] Non-enzymatic Glucose Sensor Based on Palladium Coated Nanoporous Gold Film Electrode
    Tavakkoli, Nahid
    Nasrollahi, Shekofe
    [J]. AUSTRALIAN JOURNAL OF CHEMISTRY, 2013, 66 (09) : 1097 - 1104
  • [3] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [4] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [5] Fully packaged non-enzymatic glucose micro-sensor for in-vivo and continuously monitoring system applications
    Park, Dae J.
    Lee, Yi J.
    Park, Jae Y.
    [J]. 2007 IEEE SENSORS, VOLS 1-3, 2007, : 75 - 78
  • [6] Electrochemically roughened nanoporous platinum electrodes for non-enzymatic glucose sensors
    Weremfo, Alexander
    Fong, Sui Tung Clara
    Khan, Asim
    Hibbert, David B.
    Zhao, Chuan
    [J]. ELECTROCHIMICA ACTA, 2017, 231 : 20 - 26
  • [7] Non-Enzymatic Glucose Sensor based on Electrodeposition of Platinum Particles on Polyaniline Modified Pt Electrode
    Malhotra, Shveta
    Tang, Yijun
    Varshney, Pradeep K.
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2018, 10 (06): : 699 - 715
  • [8] Amperometric non-enzymatic bimetallic glucose sensor based on platinum tellurium microtubes modified electrode
    Guascito, Maria Rachele
    Chirizzi, Daniela
    Malitesta, Cosimino
    Siciliano, Maria
    Siciliano, Tiziana
    Tepore, Antonio
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2012, 22 : 45 - 48
  • [9] Disposable non-enzymatic blood glucose sensing strip based on nanoporous platinum particles
    Lee, Saram
    Lee, Joungmin
    Park, Sejin
    Boo, Hankil
    Kim, Hee Chan
    Chung, Taek Dong
    [J]. APPLIED MATERIALS TODAY, 2018, 10 : 24 - 29
  • [10] Nanoporous CuO layer modified Cu electrode for high performance enzymatic and non-enzymatic glucose sensing
    Li, Changli
    Kurniawan, Mario
    Sun, Dali
    Tabata, Hitoshi
    Delaunay, Jean-Jacques
    [J]. NANOTECHNOLOGY, 2015, 26 (01)