Nonlinear frequency response analysis for the diagnosis of carbon monoxide poisoning in PEM fuel cell anodes

被引:31
|
作者
Kadyk, Thomas [1 ,2 ]
Hanke-Rauschenbach, Richard [1 ]
Sundmacher, Kai [1 ,2 ]
机构
[1] Max Planck Inst Dynam Complex Tech Syst, D-39106 Magdeburg, Germany
[2] Otto VonGuericke Univ Magdegurg, D-39106 Magdeburg, Germany
关键词
Polymer electrolyte membrane fuel cell; Nonlinear frequency response analysis; Higher order frequency response function; Carbon monoxide; ELECTROCHEMICAL IMPEDANCE SPECTRA; HYDROGEN OXIDATION REACTION; POTENTIAL OSCILLATIONS; H-2/CO MIXTURES; REFORMATE FEED; CO TOLERANCE; ELECTRODE; KINETICS; MODEL; OXIDE;
D O I
10.1007/s10800-011-0298-8
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Anodic CO poisoning of a PEMFC was analysed by nonlinear frequency response analysis (NFRA) in a differential H-2/H-2 cell. This special experimental setup excluded potential masking effects, emphasised the main mechanism of CO poisoning and made a simplified modelling approach possible. The main features of CO poisoning were investigated by means of steady state polarisation, EIS and NFRA. The main characteristics of CO poisoning in the NFRA spectra can be used as a "fingerprint" for diagnostic purposes.
引用
收藏
页码:1021 / 1032
页数:12
相关论文
共 50 条
  • [31] Measurement and modelling of carbon monoxide poisoning distribution within a polymer electrolyte fuel cell
    Brett, D. J. L.
    Aguiar, P.
    Brandon, N. P.
    Kucernak, A. R.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2007, 32 (07) : 863 - 871
  • [32] Carbon monoxide tolerant anodes for proton exchange membrane (PEM) fuel cells. II. Alloy catalyst development
    Holleck, GL
    Pasquariello, DM
    Clauson, SL
    PROCEEDINGS OF THE SECOND INTERNATIONAL SYMPOSIUM ON PROTON CONDUCTING MEMBRANE FUEL CELL II, 1999, 98 (27): : 150 - 161
  • [33] Unconventional frequency response analysis of PEM fuel cell based on high-order frequency response function and total harmonic distortion
    Yuan, Hao
    Zhou, Shulin
    Zhang, Shaozhe
    Tang, Wei
    Jiang, Bo
    Wei, Xuezhe
    Dai, Haifeng
    APPLIED ENERGY, 2024, 357
  • [34] THE DIAGNOSIS AND THERAPY OF ENCEPHALOPATHY IN CARBON-MONOXIDE POISONING
    NOVIKOVA, RI
    CHERNY, VI
    GRIGORENKO, AP
    SOVETSKAYA MEDITSINA, 1988, (08): : 95 - &
  • [35] CARBON-MONOXIDE POISONING, A DIAGNOSIS FREQUENTLY OVERLOOKED
    BARRET, L
    DANEL, V
    FAURE, J
    JOURNAL OF TOXICOLOGY-CLINICAL TOXICOLOGY, 1985, 23 (4-6): : 309 - 313
  • [36] XPS analysis of carbon-supported platinum electrodes and characterization of CO oxidation on PEM fuel cell anodes by electrochemical half cell methods
    Rheaume, JM
    Muller, B
    Schulze, M
    JOURNAL OF POWER SOURCES, 1998, 76 (01) : 60 - 68
  • [37] Stem cell rescue for carbon monoxide poisoning?
    Thom, Stephen
    CRITICAL CARE MEDICINE, 2009, 37 (04) : 1520 - 1521
  • [38] Carbon monoxide poisoning of proton exchange membrane fuel cells
    Baschuk, JJ
    Li, XG
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (08) : 695 - 713
  • [39] Carbon monoxide clean-up of the reformate gas for PEM fuel cell applications: A conceptual review
    Sahebdelfar, Saeed
    Ravanchi, Maryam Takht
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (64) : 24709 - 24729
  • [40] Carbon deposition on nickel cermet anodes of solid oxide fuel cells operating on carbon monoxide fuel
    Li, Chen
    Shi, Yixiang
    Cai, Ningsheng
    JOURNAL OF POWER SOURCES, 2013, 225 : 1 - 8