A Microfluidic-Based Investigation of Bacterial Attachment in Ureteral Stents

被引:23
|
作者
De Grazia, Antonio [1 ,2 ]
LuTheryn, Gareth [1 ]
Meghdadi, Alireza [1 ]
Mosayyebi, Ali [1 ,2 ]
Espinosa-Ortiz, Erika J. [3 ]
Gerlach, Robin [3 ]
Carugo, Dario [1 ,2 ]
机构
[1] Univ Southampton, Bioengn Sci Res Grp, Fac Engn & Phys Sci, Southampton SO17 1BJ, Hants, England
[2] Univ Southampton, Inst Life Sci IfLS, Southampton SO17 1BJ, Hants, England
[3] Montana State Univ, Ctr Biofilm Engn, Bozeman, MT 59717 USA
基金
英国生物技术与生命科学研究理事会; “创新英国”项目;
关键词
ureteral obstruction; ureteral stent; microfluidics; stent-on-a-chip; bacterial attachment; biofilm formation; cavity flow; wall shear stress; CFD simulations; BIOFILMS;
D O I
10.3390/mi11040408
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Obstructions of the ureter lumen can originate from intrinsic or extrinsic factors, such as kidney stones, tumours, or strictures. These can affect the physiological flow of urine from the kidneys to the bladder, potentially causing infection, pain, and kidney failure. To overcome these complications, ureteral stents are often deployed clinically in order to temporarily re-establish urinary flow. Despite their clinical benefits, stents are prone to encrustation and biofilm formation that lead to reduced quality of life for patients; however, the mechanisms underlying the formation of crystalline biofilms in stents are not yet fully understood. In this study, we developed microfluidic-based devices replicating the urodynamic field within different configurations of an occluded and stented ureter. We employed computational fluid dynamic simulations to characterise the flow dynamic field within these models and investigated bacterial attachment (Pseudomonas fluorescens) by means of crystal violet staining and fluorescence microscopy. We identified the presence of hydrodynamic cavities in the vicinity of a ureteric occlusion, which were characterised by low levels of wall shear stress (WSS < 40 mPa), and observed that initiation of bacterial attachment occurred in these specific regions of the stented ureter. Notably, the bacterial coverage area was directly proportional to the number of cavities present in the model. Fluorescence microscopy confirmed that the number density of bacteria was greater within cavities (3 bacteriamm(-2)) when compared to side-holes of the stent (1 bacteriummm(-2)) or its luminal surface (0.12 bacteriamm(-2)). These findings informed the design of a novel technological solution against bacterial attachment, which reduces the extent of cavity flow and increases wall shear stress over the stent's surface.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Microfluidic-based processors and circuits design
    Azizbeigi, Kasra
    Pedram, Maysam Zamani
    Sanati-Nezhad, Amir
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [22] Attachment and detachment of living cells on modified microchannel surfaces in a microfluidic-based lab-on-a-chip system
    Zhang, Xunli
    Jones, Paul
    Haswell, Stephen J.
    CHEMICAL ENGINEERING JOURNAL, 2008, 135 (SUPPL. 1) : S82 - S88
  • [23] A Microfluidic-Based Fabry Perot Gas Sensor
    Tao, Jin
    Zhang, Qiankun
    Xiao, Yunfeng
    Li, Xiaoying
    Yao, Pei
    Pang, Wei
    Zhang, Hao
    Duan, Xuexin
    Zhang, Daihua
    Liu, Jing
    MICROMACHINES, 2016, 7 (03):
  • [24] Droplet enhanced microfluidic-based DNA purification from bacterial lysates via phenol extraction
    Morales, Mercedes C.
    Zahn, Jeffrey D.
    MICROFLUIDICS AND NANOFLUIDICS, 2010, 9 (06) : 1041 - 1049
  • [25] On the Application of Microfluidic-Based Technologies in Forensics: A Review
    Bazyar, Hanieh
    SENSORS, 2023, 23 (13)
  • [26] Microfluidic-based nanoparticle synthesis and their potential applications
    Khizar, Sumera
    Zine, Nadia
    Errachid, Abdelhamid
    Jaffrezic-Renault, Nicole
    Elaissari, Abdelhamid
    ELECTROPHORESIS, 2022, 43 (7-8) : 819 - 838
  • [27] Microfluidic-Based Approaches for Foodborne Pathogen Detection
    Zhao, Xihong
    Li, Mei
    Liu, Yao
    MICROORGANISMS, 2019, 7 (10)
  • [28] Evaluation of a microfluidic-based point-of-care prototype with customized chip for detection of bacterial clusters
    Treffon, Janina
    Isserstedt-John, Nicole
    Klemm, Richard
    Gaertner, Claudia
    Mellmann, Alexander
    MICROBIOLOGY SPECTRUM, 2024, 12 (12):
  • [29] Ureteral Stents Do Not Cause Bacterial Infections in Children After Ureteral Reimplantation
    Uvin, Pieter
    Van Baelen, Anthony
    Verhaegen, Jan
    Bogaert, Guy
    UROLOGY, 2011, 78 (01) : 154 - 158
  • [30] Flow Analysis of Microfluidic-based Acoustic Sensor
    Rahman, M. F. A.
    Arshad, M. R.
    Manaf, A. A.
    Yaacob, M. I. H.
    2012 4TH INTERNATIONAL CONFERENCE ON INTELLIGENT AND ADVANCED SYSTEMS (ICIAS), VOLS 1-2, 2012, : 398 - 401