Rapid and Label-Free Isolation of Tumour Cells from the Urine of Patients with Localised Prostate Cancer Using Inertial Microfluidics

被引:54
|
作者
Rzhevskiy, Alexey S. [1 ,2 ,3 ]
Bazaz, Sajad Razavi [4 ]
Ding, Lin [4 ]
Kapitannikova, Alina [1 ,2 ]
Sayyadi, Nima [1 ,5 ]
Campbell, Douglas [6 ]
Walsh, Bradley [6 ]
Gillatt, David [3 ]
Warkiani, Majid Ebrahimi [2 ,4 ]
Zvyagin, Andrei V. [1 ,2 ]
机构
[1] Macquarie Univ, MQ Photon, ARC Ctr Excellence Nanoscale BioPhoton, Sydney, NSW 2109, Australia
[2] Sechenov First Moscow State Med Univ, Inst Mol Med, Moscow 119991, Russia
[3] Macquarie Univ, Dept Clin Med, Fac Med & Hlth Sci, Sydney, NSW 2109, Australia
[4] Univ Technol Sydney, Sch Biomed Engn, Sydney, NSW 2007, Australia
[5] Macquarie Univ, Dept Mol Sci, Sydney, NSW 2109, Australia
[6] Minom Int Ltd, Sydney, NSW 2113, Australia
关键词
prostate cancer; inertial microfluidics; cell separation; tumour cells; glycoprotein; ULTRA-FAST;
D O I
10.3390/cancers12010081
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
During the last decade, isolation of circulating tumour cells via blood liquid biopsy of prostate cancer (PCa) has attracted significant attention as an alternative, or substitute, to conventional diagnostic tests. However, it was previously determined that localised forms of PCa shed a small number of cancer cells into the bloodstream, and a large volume of blood is required just for a single test, which is impractical. To address this issue, urine has been used as an alternative to blood for liquid biopsy as a truly non-invasive, patient-friendly test. To this end, we developed a spiral microfluidic chip capable of isolating PCa cells from the urine of PCa patients. Potential clinical utility of the chip was demonstrated using anti-Glypican-1 (GPC-1) antibody as a model of the primary antibody in immunofluorescent assay for identification and detection of the collected tumour cells. The microchannel device was first evaluated using DU-145 cells in a diluted Dulbecco's phosphate-buffered saline sample, where it demonstrated >85 (+/- 6) % efficiency. The microchannel proved to be functional in at least 79% of cases for capturing GPC1+ putative tumour cells from the urine of patients with localised PCa. More importantly, a correlation was found between the amount of the captured GPC1+ cells and crucial diagnostic and prognostic parameter of localised PCa-Gleason score. Thus, the technique demonstrated promise for further assessment of its diagnostic value in PCa detection, diagnosis, and prognosis.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Rapid Label-Free Isolation of Circulating Tumor Cells from Patients' Peripheral Blood Using Electrically Charged Fe3O4 Nanoparticles
    Wu, Shengming
    Gu, Lei
    Qn, Jingwen
    Zhang, Lei
    Sun, Fenyong
    Liu, Zhongchen
    Wang, Yilong
    Shi, Donglu
    ACS APPLIED MATERIALS & INTERFACES, 2020, 12 (04) : 4193 - 4203
  • [32] Integrated inertial-impedance cytometry for rapid label-free leukocyte isolation and profiling of neutrophil extracellular traps (NETs)
    Petchakup, Chayakorn
    Tay, Hui Min
    Li, King Ho Holden
    Hou, Han Wei
    LAB ON A CHIP, 2019, 19 (10) : 1736 - 1746
  • [33] Random Lasing from Label-Free Living Cells for Rapid Cytometry of Apoptosis
    Xu, Zhiyang
    Hong, Qihao
    Ge, Kun
    Shi, Xiaoyu
    Wang, Xiaolei
    Deng, Jinxiang
    Zhou, ZhiXiang
    Zhai, Tianrui
    NANO LETTERS, 2022, 22 (01) : 172 - 178
  • [34] Label-Free, High-Throughput Purification of Satellite Cells Using Microfluidic Inertial Separation
    Syverud, Brian C.
    Lin, Eric
    Nagrath, Sunitha
    Larkin, Lisa M.
    TISSUE ENGINEERING PART C-METHODS, 2018, 24 (01) : 32 - 41
  • [35] Label-free Identification of Nonelectrogenic Cancer Cells using Adhesion Noise
    Ell, Maximilian
    Zeitler, Ralf
    Thewes, Roland
    Zeck, Guenther
    2023 IEEE BIOSENSORS CONFERENCE, BIOSENSORS, 2023,
  • [36] Label-free isolation of a prostate cancer cell among blood cells and the single-cell measurement of drug accumulation using an integrated microfluidic chip
    Khamenehfar, A.
    Beischlag, T. V.
    Russell, P. J.
    Ling, M. T. P.
    Nelson, C.
    Li, P. C. H.
    BIOMICROFLUIDICS, 2015, 9 (06)
  • [37] Isolation and label-free detection of circulating tumour cells by fluidic diffraction chips with a reflective laser beam system
    Lin, Feng-Ping
    Hsu, Hui-Ling
    Chang, Chi-Jung
    Lu, Chien-Hsing
    Chen, Jem-Kun
    CHEMICAL ENGINEERING JOURNAL, 2022, 436
  • [38] Label-free collection of prostate circulating tumor cells using microfluidic Vortex technology
    Pao, Edward
    Renier, Corinne
    Lemaire, Clementine
    Che, James
    Di Carlo, Melissa Matsumoto
    Triboulet, Melanie
    Srivinas, Sandy
    Jeffrey, Stefanie S.
    Kulkarni, Rajan P.
    Rettig, Matthew
    Sollier, Elodie
    Di Carlo, Dino
    CANCER RESEARCH, 2016, 76
  • [39] Label-Free Prostate Cancer Detection by Characterization of Extracellular Vesicles Using Raman Spectroscopy
    Lee, Wooje
    Nanou, Afroditi
    Rikkert, Linda
    Coumans, Frank A. W.
    Otto, Cees
    Terstappen, Leon W. M. M.
    Offerhaus, Herman L.
    ANALYTICAL CHEMISTRY, 2018, 90 (19) : 11290 - 11296
  • [40] Raman and Polarization-sensitive digital holographic imaging for rapid and label-free prostate cancer diagnosis
    Khadem, Hossein
    Ferrara, Maria Antonietta
    Mangini, Maria
    Luini, Alberto
    Coppola, Giuseppe
    De Luca, Anna Chiara
    EOS ANNUAL MEETING, EOSAM 2024, 2024, 309