Tilted versus axial implant distribution in the posterior edentulous maxilla: A CBCT analysis

被引:5
|
作者
Hamilton, Adam [1 ,2 ]
Jamjoom, Faris Z. [1 ,3 ]
Alnasser, Muhsen [1 ]
Starr, Jacqueline R. [4 ,5 ]
Friedland, Bernard [6 ]
Gallucci, German O. [7 ]
机构
[1] Harvard Sch Dent Med, Div Regenerat & Implant Sci, Dept Restorat Dent & Biomat Sci, Boston, MA USA
[2] Univ Western Australia, Div Oral Restorat & Rehabil Sci, Perth, WA, Australia
[3] King Saud Bin Abdulaziz Univ Hlth Sci, Coll Dent, Dept Restorat & Prosthet Dent Sci, Riyadh, Saudi Arabia
[4] Brigham & Womens Hosp, Channing Div Network Med, 75 Francis St, Boston, MA 02115 USA
[5] Harvard Sch Dent Med, Dept Oral Hlth Policy & Epidemiol, Boston, MA USA
[6] Harvard Sch Dent Med, Dept Oral Med Infect & Immun, Boston, MA USA
[7] Harvard Sch Dent Med, Chair Dept Restorat Dent & Biomat Sci, Boston, MA USA
基金
美国国家卫生研究院;
关键词
angled implants; dental implants; maxillary sinus; tilted implants; virtual implant planning; SHORT DENTAL IMPLANTS; ITI CONSENSUS REPORT; STRESS-DISTRIBUTION; ZYGOMATIC IMPLANTS; LONGER IMPLANTS; 6; MM; REHABILITATION; SURVIVAL; PROSTHESES; DIAMETER;
D O I
10.1111/clr.13836
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aimed to determine whether distally angulating an implant is a successful strategy to avoid the maxillary sinus and the need for bone augmentation, while increasing the anterior-posterior (A-P) implant distribution in the edentulous maxilla. Materials and Methods In 115 patients with edentulous maxillae, virtual implant planning was performed utilizing cone-beam computer tomographs. Axial (8 mm length) and tilted (12 mm length) dental implants with 30-degree and 45-degree angulation were virtually positioned to avoid entering the maxillary sinus, while maximizing A-P distribution. Measurements were made between the tilted and axial implants to assess the change in A-P distribution of implants at the implant and abutment levels. Results Forty-seven sites (20.4%) were not able to have either treatment modality with insufficient bone for implant placement. Axial implants were placed more distally than 45-degree and 30-degree tilted implants in 24% and 42% of sites, respectively. The average change in A-P spread measured at the implant level, for 30- and 45-degree tilted implants was -0.25 mm (95% CI -0.76, 0.26) and 1.9 mm (95% CI 1.4, 2.3), respectively. When measured from the center of each multi-unit abutment the average increase in A-P distances for tilted implants appears larger in the 30-degree and 45-degree groups by 0.97 mm and 1.74 mm, respectively compared to measurements at the implant level. Conclusions Angulating 12 mm implants provides a limited increase in A-P distribution of implants in edentulous rehabilitation in most situations. In certain patients, the use of 8mm axial implants may provide a greater A-P spread.
引用
收藏
页码:1357 / 1365
页数:9
相关论文
共 50 条
  • [31] Effect of Splinting of Tilted External Hexagon Implants on 3-Unit Implant-Supported Prostheses in the Posterior Maxilla: A 3D Finite Element Analysis
    de Faria Almeida, Daniel A.
    Verri, Fellippo R.
    Lemos, Cleidiel A. A.
    de Souza Batista, Victor E.
    Santiago Junior, Joel F.
    Rosa, Cleber D. D. R. D.
    Noritomi, Pedro Y.
    Pellizzer, Eduardo P.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (08): : 697 - 704
  • [32] Clinical Investigation on Axial versus Tilted Implants for Immediate Fixed Rehabilitation of Edentulous Arches: Preliminary Results of a Single Cohort Study
    Agnini, Alessandro
    Agnini, Andrea Mastrorosa
    Romeo, Davide
    Chiesi, Manuele
    Pariente, Leon
    Stappert, Christian F. J.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (04) : 527 - 539
  • [33] Influence of Cantilever Extension and Crown-to-Implant Ratio in Posterior Maxilla: A Finite Element Analysis
    Gungor, Hamiyet
    Baran, Ilgi
    Karaagaclioglu, Lale
    JOURNAL OF BIOMATERIALS AND TISSUE ENGINEERING, 2018, 8 (04) : 489 - 495
  • [34] Comparison of Marginal Bone Loss Around Axial and Tilted Implants: A Retrospective CBCT Analysis of Up to 24 Months
    Bruschi, Ernesto
    Manicone, Paolo Francesco
    De Angelis, Paolo
    Papetti, Laura
    Pastorino, Roberta
    D'Addona, Antonio
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2019, 39 (05) : 675 - +
  • [35] Influence of Arch Shape and Implant Position on Stress Distribution Around Implants Supporting Fixed Full-Arch Prosthesis in Edentulous Maxilla
    Sagat, Giray
    Yalcin, Serdar
    Gultekin, B. Alper
    Mijiritsky, Eitan
    IMPLANT DENTISTRY, 2010, 19 (06) : 498 - 508
  • [36] Effectiveness of zygomatic-implant fixed rehabilitation for the atrophic edentulous maxilla: protocol for a systematic review and network meta-analysis
    Rodrigues, Anisha
    Abi-Nader, Samer
    Durand, Robert
    Rompre, Pierre
    Janati, Amal Idrissi
    Atsu, Saadet
    Morris, Martin
    Emami, Elham
    SYSTEMATIC REVIEWS, 2024, 13 (01)
  • [37] Biomechanical analysis of the effects of implant diameter and bone quality in short implants placed in the atrophic posterior maxilla
    Chang, Shih-Hao
    Lin, Chun-Li
    Hsue, Shue-Sang
    Lin, Yang-Sung
    Huang, Shiang-Rung
    MEDICAL ENGINEERING & PHYSICS, 2012, 34 (02) : 153 - 160
  • [38] A two-short-implant-supported molar restoration in atrophic posterior maxilla: A finite element analysis
    Song, Ho-Yong
    Huh, Yoon-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    JOURNAL OF ADVANCED PROSTHODONTICS, 2016, 8 (04): : 304 - 312
  • [39] The optional apex sites for quad zygomatic implant placement in edentulous patients with severe alveolar bone resorption: a CBCT anatomical analysis
    Jiayi Wang
    Bo Chen
    Yuexin Zhao
    Shaoxia Pan
    Xiangliang Xu
    BMC Oral Health, 24 (1)
  • [40] Evaluation of the effect of an offset implant configuration in the posterior maxilla with external hexagon implant platform: A 3-dimensional finite element analysis
    de Souza Batista, Victor Eduardo
    Verri, Fellippo Ramos
    de Faria Almeida, Daniel Augusto
    Santiago Junior, Joel Ferreira
    Araujo Lemos, Cleidiel Aparecido
    Pellizzer, Eduardo Piza
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 118 (03): : 363 - 371