Quantitative attenuation accuracy of virtual non-enhanced imaging compared to that of true non-enhanced imaging on dual-source dual-energy CT

被引:26
|
作者
Javadi, Sanaz [1 ]
Elsherif, Sherif [2 ]
Bhosale, Priya [1 ]
Jensen, Corey T. [1 ]
Layman, Rick R. [3 ]
Jacobsen, Megan C. [3 ]
Le, Ott [1 ]
Jia, Sun [4 ]
Parikh, Rajan J. [5 ]
Tamm, Eric P. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Abdominal Imaging, 1400 Pressler St,Unit 1437, Houston, TX 77030 USA
[2] Univ Illinois, Weiss Mem Hosp, Dept Internal Med, Chicago, IL USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX 77030 USA
[4] Univ Texas MD Anderson Canc Ctr, Dept Biostat, Houston, TX 77030 USA
[5] Univ Calif Berkeley, Dept Bioengn, Berkeley, CA 94720 USA
关键词
DECT; dual-energy computed tomography; VNC; virtual non-contrast computed tomography; TNC; true non-contrast computed tomography; IODINE QUANTIFICATION; NON-CONTRAST;
D O I
10.1007/s00261-020-02415-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the quantitative attenuation and reliability of virtual non-contrast (VNC) images of the abdomen acquired from multiphasic scans with a dual-energy computed tomography (DECT) system and compare it with that of true non-enhanced images (TNC) on second- (Flash) and third- (Force) generation DECT scanners. Methods This retrospective study was approved by the institutional review board and included 123 patients with pancreatic cancer who had undergone routine clinical multiphasic DECT examinations at our institution using Flash and Force scanners between March and August 2017. VNC images of the abdomen were reconstructed from late arterial phase images. For every patient, regions-of-interest were defined in the aorta, fluid-containing structures (gallbladder, pleural effusion, and renal cysts > 10 mm), paravertebral muscles, subcutaneous fat, spleen, pancreas, renal cortex, and liver (eight locations) on TNC and VNC images. The mean attenuation of VNC was compared with TNC by organ for each CT scanner using an equivalence test and the Bland-Altman plot. The mean attenuations for TNC or VNC were compared between the Force and Flash CT scanners using a two-sample t test. Results The VNC attenuation of organs on the Force scanner was lower than was that on the Flash, and the mean attenuation difference in different organs on the Force was closer to 0. The estimated means of TNC and VNC were equivalent for an equivalence margin of 10 on the Force scanner. Conclusion VNC images in DECT are a promising alternative to TNC images. In clinical scenarios in which non-enhanced CT images are required but are not available for accurate diagnosis, VNC images can potentially serve as an alternative to TNC images without the radiation exposure risks.
引用
收藏
页码:1100 / 1109
页数:10
相关论文
共 50 条
  • [21] Pancreatic dual-source dual-energy CT: Is it time to discard unenhanced imaging?
    Mileto, Achille
    Mazziotti, Silvio
    Gaeta, Michele
    Bottari, Antonio
    Zimbaro, Fabrizio
    Giardina, Claudio
    Ascenti, Giorgio
    CLINICAL RADIOLOGY, 2012, 67 (04) : 334 - 339
  • [22] Abdominal Attenuation Values on Virtual and True Unenhanced Images Obtained With Third-Generation Dual-Source Dual-Energy CT
    Durieux, Pierre
    Gevenois, Pierre Alain
    Van Muylem, Alain
    Howarth, Nigel
    Keyzer, Caroline
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 210 (05) : 1042 - 1058
  • [23] Dual-energy CT quantitative imaging: a comparison study between twin-beam and dual-source CT scanners
    Almeida, Isabel P.
    Schyns, Lotte E. J. R.
    Ollers, Michel C.
    van Elmpt, Wouter
    Parodi, Katia
    Landry, Guillaume
    Verhaegen, Frank
    MEDICAL PHYSICS, 2017, 44 (01) : 171 - 179
  • [24] Comparison of True and Virtual Non-Contrast Images of Liver Obtained with Single-Source Twin Beam and Dual-Source Dual-Energy CT
    Lee, Jeong Sub
    Choi, Guk Myung
    Kim, Bong Soo
    Ko, Su Yeon
    Lee, Kyung Ryeol
    Kim, Jeong Jae
    Kim, Doo Ri
    JOURNAL OF THE KOREAN SOCIETY OF RADIOLOGY, 2023, 84 (01): : 170 - 184
  • [25] Non-Enhanced MR Imaging of Cerebral Arteriovenous Malformations at 7 Tesla
    Wrede, Karsten H.
    Dammann, Philipp
    Johst, Soeren
    Moenninghoff, Christoph
    Schlamann, Marc
    Maderwald, Stefan
    Sandalcioglu, I. Erol
    Ladd, Mark E.
    Forsting, Michael
    Sure, Ulrich
    Umutlu, Lale
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 829 - 839
  • [26] Intraoperative perfusion-weighted imaging in non-enhanced glioma surgery
    Chen, Zhong-Jun
    Zheng, Jin-Long
    Guan, Wei
    Liu, Wen-Guang
    Zheng, Jin-Yu
    Zuo, Jian-Dong
    MINERVA CHIRURGICA, 2019, 74 (04) : 313 - 319
  • [27] Utility of non-enhanced magnetic resonance imaging to detect acute pyelonephritis
    Aoyagi, Jun
    Odaka, Jun
    Kuroiwa, Yuri
    Nakashima, Naomi
    Ito, Takane
    Saito, Takashi
    Kanai, Takahiro
    Yamagata, Takanori
    Momoi, Mariko Y.
    PEDIATRICS INTERNATIONAL, 2014, 56 (03) : e4 - e6
  • [28] X-Ray Spectra Optimization for Dual-Energy Imaging Using Dual-Source CT
    Giraldo, J. Ramirez
    Primak, A.
    Liu, X.
    McCollough, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [29] Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma
    Salim Si-Mohamed
    Nicolas Dupuis
    Valérie Tatard-Leitman
    David Rotzinger
    Sara Boccalini
    Matthias Dion
    Alain Vlassenbroek
    Philippe Coulon
    Yoad Yagil
    Nadav Shapira
    Philippe Douek
    Loic Boussel
    European Radiology, 2019, 29 : 6762 - 6771
  • [30] Virtual versus true non-contrast dual-energy CT imaging for the diagnosis of aortic intramural hematoma
    Si-Mohamed, Salim
    Dupuis, Nicolas
    Tatard-Leitman, Valerie
    Rotzinger, David
    Boccalini, Sara
    Dion, Matthias
    Vlassenbroek, Alain
    Coulon, Philippe
    Yagil, Yoad
    Shapira, Nadav
    Douek, Philippe
    Boussel, Loic
    EUROPEAN RADIOLOGY, 2019, 29 (12) : 6762 - 6771