Optimization method for systematically improving non-contact R test accuracy

被引:5
|
作者
Jiang, Lei [1 ]
Peng, Bingkang [1 ]
Ding, Guofu [1 ]
Qin, Shengfeng [2 ]
Zhang, Jian [1 ]
Li, Yong [1 ]
机构
[1] Southwest Jiaotong Univ, Sch Mech Engn, Inst Adv Design & Mfg, Chengdu 610031, Sichuan, Peoples R China
[2] Northumbria Univ, Sch Design, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
关键词
Optimization method; Non-contact R test; Structural parameter; On-machine calibration; Measurement accuracy; ROTARY AXES; CALIBRATION; ERRORS; MODEL;
D O I
10.1007/s00170-020-04999-3
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Non-contact R test is an instrument to measure the synchronous errors of five-axis machine tools. However, there are still some deficiencies in its researches, such as the difficult and laborious calibrations. How to systematically improve the measurement accuracy with a good balance to minimum cost is a real problem in guiding practice. This paper proposes a new systematic optimization method to solve this problem based on a comprehensive understanding of the non-contact R test in terms of structure parameters and relations. Firstly, the algorithm for sphere center coordinates is established based on the self-adaptive differential evolution algorithm to obtain the definite computational accuracy and efficiency. Secondly, the parameters of the fixture structure are optimized to maximize the measurement stability, measuring space, and non-interference space. Thirdly, the on-machine calibration is performed to replace pre-calibration and re-calibration and to establish the positional relationships between sensors, the fixture, and the machine tool simultaneously. It can reduce the difficulties of manufacture, maintenance, and application. Fourthly, the measurement accuracy can be evaluated to determine whether the iterative optimization achieves the goal. The proposed method has been verified with case studies to support the setting-up of the optimized non-contact R test, leading to a cost-effective and accurate test on five-axis machine tools.
引用
收藏
页码:1697 / 1711
页数:15
相关论文
共 50 条
  • [21] Non-contact Hall method: application to superconductors
    Gilchrist, J
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2000, 13 (11): : 1533 - 1538
  • [22] Photoelectric method for non-contact characterization of SiGe
    Tsidilkovski, Edward
    Steeples, Kenneth
    THIN SOLID FILMS, 2008, 517 (01) : 170 - 171
  • [23] An optoelectronic non-contact inspecting method of taper
    Zhang, GY
    An, ZY
    Jiang, HL
    Li, CZ
    Gao, YJ
    Chen, RW
    AUTOMATED OPTICAL INSPECTION FOR INDUSTRY: THEORY, TECHNOLOGY, AND APPLICATIONS II, 1998, 3558 : 239 - 243
  • [24] Non-contact multiband method for emissivity measurement
    Mazikowski, A
    Chrzanowski, K
    INFRARED PHYSICS & TECHNOLOGY, 2003, 44 (02) : 91 - 99
  • [25] METHOD FOR NON-CONTACT THICKNESS AND CONDUCTIVITY GAGING
    BALL, E
    MATERIALS EVALUATION, 1975, 33 (09) : A54 - &
  • [26] New method for non-contact material testing
    Adhaesion Kleben und Dichten, 2019, 63 (09): : 38 - 41
  • [27] Accuracy and reliability of the Keeler Pulsair EasyEye non-contact tonometer
    Ogbuehi, Kelechi C.
    Almubrad, Turki M.
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (01) : 61 - 66
  • [28] INDUCTIVE NON-CONTACT METHOD FOR MEASURING A VELOCITY
    GAJEWSKI, JB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1983, 16 (07): : 622 - 624
  • [29] Accuracy advancement of non-contact temperature measurement with differential technology
    Xu, K. B.
    Wang, J. C.
    Gao, L. L.
    Li, X. B.
    4th International Symposium on Instrumentation Science and Technology (ISIST' 2006), 2006, 48 : 720 - 724
  • [30] Optimization design and test on non-contact thermal resistance heat exchanger of air-condition
    Jia, Runze
    Wang, Yichun
    Wang, Hong
    Rong, Jun
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2014, 42 (07): : 12 - 16