Numerical Study on Fluid-Structure Interaction in a Patient-Specific Abdominal Aortic Aneurysm for Evaluating Wall Heterogeneity and Material Model Effects on its Rupture

被引:12
|
作者
Mesri, Y. [1 ,2 ]
Niazmand, H. [1 ,2 ]
Deyranlou, A. [1 ,2 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Res Ctr Biomed Engn, Mashhad, Iran
关键词
Abdominal aortic aneurysm; Fluid-structure interaction; Material model; Wall thickness; INTRALUMINAL THROMBUS; BLOOD-FLOW; STRESS-ANALYSIS; RISK; BIOMECHANICS; IDENTIFICATION; PREDICTION; MECHANICS; DIAMETER; GEOMETRY;
D O I
10.18869/acadpub.jafm.73.243.27678
中图分类号
O414.1 [热力学];
学科分类号
摘要
Abdominal Aortic Aneurysm (AAA) is one of the main cardiovascular diseases, which threats human's health while it appears, develops and in crucial cases ruptures and leads to hemorrhage. In the current work, we aim to investigate numerically the transient blood flow in a patient-specific AAA model, while effects of wall compliance is considered by employing the fluid-structure interaction method. The AAA model is reconstructed from acquired CT angiographic data of a patient diagnosed with AAA and an intraluminal thrombus (ILT). For the comparison purposes two different material models, i.e. isotropic and anisotropic are considered. Additionally, to have a better estimation, wall thickness variability is compared with simpler uniform wall thickness model. In this study Navier-Stokes equations along with elastodynamics equation are coupled through Arbitrary Lagrangian-Eulerian formulation method and solved numerically. Findings demonstrate that the isotropic material model with uniform wall thickness significantly underestimates wall stresses as compared to the anisotropic material model with variable wall thickness. Indeed, results emphasize that considering vessel wall as an anisotropic, heterogeneous (variable thickness) structure estimates much higher wall stresses comparing with isotropic, uniform thickness model. Therefore, given realistic vessel wall structure and the fact that the anisotropic, variable wall thickness model predicts higher wall stresses, it could be a more reliable model to give an accurate estimation to physicians to diagnose the stage of a disease and choosing an appropriate therapeutic procedure.
引用
收藏
页码:1699 / 1709
页数:11
相关论文
共 50 条
  • [21] Fluid-structure interaction of patient-specific Circle of Willis with aneurysm: Investigation of hemodynamic parameters
    Jahed, Mahsa
    Ghalichi, Farzan
    Farhoudi, Mehdi
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2018, 29 (03) : 357 - 368
  • [22] Fluid-structure interaction modeling of a patient-specific cerebral aneurysm: influence of structural modeling
    Torii, Ryo
    Oshima, Marie
    Kobayashi, Toshio
    Takagi, Kiyoshi
    Tezduyar, Tayfun E.
    COMPUTATIONAL MECHANICS, 2008, 43 (01) : 151 - 159
  • [23] Integrated particle image velocimetry and fluid–structure interaction analysis for patient-specific abdominal aortic aneurysm studies
    Can Özcan
    Özgür Kocatürk
    Civan Işlak
    Cengizhan Öztürk
    BioMedical Engineering OnLine, 22
  • [24] A fluid-structure interaction study using patient-specific ruptured and unruptured aneurysm: The effect of aneurysm morphology, hypertension and elasticity
    Lee, C. J.
    Zhang, Y.
    Takao, H.
    Murayama, Y.
    Qian, Y.
    JOURNAL OF BIOMECHANICS, 2013, 46 (14) : 2402 - 2410
  • [25] Abdominal Aortic Aneurysm Risk of Rupture: Patient-Specific FSI Simulations Using Anisotropic Model
    Rissland, Peter
    Alemu, Yared
    Einav, Shmuel
    Ricotta, John
    Bluestein, Danny
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (03):
  • [26] Fluid-Structure Interaction Model of a Percutaneous Aortic Valve: Comparison with an In Vitro Test and Feasibility Study in a Patient-Specific Case
    Wu, Wei
    Pott, Desiree
    Mazza, Beniamino
    Sironi, Tommaso
    Dordoni, Elena
    Chiastra, Claudio
    Petrini, Lorenza
    Pennati, Giancarlo
    Dubini, Gabriele
    Steinseifer, Ulrich
    Sonntag, Simon
    Kuetting, Maximilian
    Migliavacca, Francesco
    ANNALS OF BIOMEDICAL ENGINEERING, 2016, 44 (02) : 590 - 603
  • [27] Fluid, solid and fluid-structure interaction simulations on patient-based abdominal aortic aneurysm models
    Kelly, Sinead
    O'Rourke, Malachy
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2012, 226 (H4) : 288 - 304
  • [28] Fluid-Structure Simulations of a Ruptured Intracranial Aneurysm: Constant versus Patient-Specific Wall Thickness
    Voss, S.
    Glasser, S.
    Hoffmann, T.
    Beuing, O.
    Weigand, S.
    Jachau, K.
    Preim, B.
    Thevenin, D.
    Janiga, G.
    Berg, P.
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2016, 2016
  • [29] On the role of tissue mechanics in fluid-structure interaction simulations of patient-specific aortic dissection
    Schussnig, Richard
    Rolf-Pissarczyk, Malte
    Baeumler, Kathrin
    Fries, Thomas-Peter
    Holzapfel, Gerhard A.
    Kronbichler, Martin
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2024, 125 (14)
  • [30] Experimental unsteady flow study in a patient-specific abdominal aortic aneurysm model
    Stamatopoulos, Ch.
    Mathioulakis, D. S.
    Papaharilaou, Y.
    Katsamouris, A.
    EXPERIMENTS IN FLUIDS, 2011, 50 (06) : 1695 - 1709