Thermal performance optimization of envelope in the energy-saving renovation of existing residential buildings

被引:46
|
作者
Huang, Jianen [1 ,2 ,3 ]
Wang, Shasha [2 ]
Teng, Feihong [2 ]
Feng, Wei [1 ,2 ]
机构
[1] China Univ Min & Technol, State Key Lab Geomech & Deep Underground Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] China Univ Min & Technol, Sch Mech & Civil Engn, Xuzhou 221116, Jiangsu, Peoples R China
[3] JiangSu Collaborat Innovat Ctr Bldg Energy Saving, Xuzhou 221116, Jiangsu, Peoples R China
关键词
Existing residential building; Energy-saving renovation; Thermal performance optimization; Ultimate and optimum energy saving ratio; OPTIMUM INSULATION THICKNESS; WALLS; ROOFS; ZONE;
D O I
10.1016/j.enbuild.2021.111103
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Based on the life cycle cost analysis, a thermal performance optimization model of building envelope was developed for the energy-saving renovation of existing residential buildings. The calculation formulas of the economic insulation layer thickness of the roof, external wall and floor over the basement were obtained simultaneously, and the optimal relationship of thermal performance among building envelope units was proposed; that is, the equivalent U-value of each opaque building envelope units should be equal. Moreover, the calculation methods of ultimate and optimum energy saving ratio were put forward. For a case study existing residential building in Beijing, compared to the energy-saving renovation sce-narios determined by the limit value method (LVM), the saving ratio of insulation material of those deter-mined by the optimization model ranges from 0.53% to 73.59%; and the saving ratio of insulation investment ranges from 0.21% to 64.93% when the building envelope energy saving ratio been taken the same value and changing from 0.65 to 0.85. The limit U-value of envelopes prescribed by Design Standard for Energy Efficiency of Residential Buildings in Beijing (DB11/891-2012) cannot meet the opti-mal relationship. Therefore, energy-saving renovation scenario determined by LVM cannot obtain the best economic benefit. The ultimate and optimum energy saving ratio achieved are inversely proportional to the U-value of windows. However, improving the performance of windows cannot necessarily achieve the best economic benefit. It is necessary to consider the technical advancement and economic rationality to choose the windows. (c) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Thermal properties optimization of envelope in energy-saving renovation of existing public buildings
    Huang, Jianen
    Lv, Henglin
    Gao, Tao
    Feng, Wei
    Chen, Yanxia
    Zhou, Tai
    [J]. ENERGY AND BUILDINGS, 2014, 75 : 504 - 510
  • [2] Study on Energy-Saving Renovation of Existing Heating Masonry-concrete Residential Buildings
    Guo, Hong
    Su, Minfang
    Jin, Xiaojun
    [J]. GREEN BUILDING MATERIALS AND ENERGY-SAVING CONSTRUCTION, 2011, 280 : 147 - 151
  • [3] ASSESSMENT OF ENERGY-SAVING POTENTIAL BASED ON THE RENOVATION OF EXISTING, RESIDENTIAL BUILDINGS IN COLD ZONES OF CHINA
    Gao Tiejun
    Li Haiying
    [J]. PROCEEDINGS OF THE 38TH INTERNATIONAL CONFERENCE ON COMPUTERS AND INDUSTRIAL ENGINEERING, VOLS 1-3, 2008, : 2302 - 2307
  • [4] Reduction in Carbon Dioxide Emission and Energy Saving Obtained by Renovation of Building Envelope of Existing Residential Buildings
    Chen, Rui
    Feng, Xiaoping
    Li, Chengjing
    Chen, Huapeng
    [J]. AEROSOL AND AIR QUALITY RESEARCH, 2021, 21 (10)
  • [5] Determination of the economical insulation thickness of building envelopes simultaneously in energy-saving renovation of existing residential buildings
    Feng, Wei
    Huang, Jianen
    Lv, Henglin
    Guo, Dapeng
    Huang, Zhaochen
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2019, 41 (06) : 665 - 676
  • [6] Thermal performance and energy-saving analysis of Guangzhou public buildings' envelope
    Zhao Lihua
    Li Ning
    Zheng Zhijuan
    [J]. PROCEEDINGS OF THE 5TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I AND II, 2007, : 824 - 829
  • [7] Energy-saving renovation in existing high-rise residential building
    Su, Minfang
    Guo, Hong
    [J]. SUSTAINABLE DEVELOPMENT AND ENVIRONMENT II, PTS 1 AND 2, 2013, 409-410 : 526 - +
  • [8] A Review of Low-Carbon and Energy-Saving Renovation of Existing Buildings
    Yu, Haitao
    Man, Qingpeng
    Feng, Kailun
    [J]. CARBON PEAK AND NEUTRALITY STRATEGIES OF THE CONSTRUCTION INDUSTRY (ICCREM 2022), 2022, : 1 - 8
  • [9] Optimization of energy-saving renovation technology for existing buildings in a hot summer and cold winter area
    Huo, Haie
    Deng, Xiaoxue
    Wei, Yanhuan
    Liu, Zhibo
    Liu, Mingrong
    Tang, Liu
    [J]. JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [10] Analysis of thermal environment of Existing Residential Building Envelope Energy-saving in ECOTECT simulation
    Zhang Suxian
    Feng Bo
    [J]. PROCEEDINGS OF THE 2016 3RD INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING, MANUFACTURING TECHNOLOGY AND CONTROL, 2016, 67 : 442 - 446