Non-contact temperature measurement by infrared pyrometer in high speed milling

被引:6
|
作者
Yang, Guang [1 ]
Hou, Junzhan [1 ,3 ]
Zhou, Wei [2 ]
Zhu, Lei [1 ]
Duan, Hongjian [1 ]
机构
[1] Xian Inst Appl Opt, Xian, Shannxi Provinc, Peoples R China
[2] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
[3] Nortwest Polytechn Univ, Sch Mech Engn, Xian 710072, Peoples R China
关键词
Milling; temperature measurement; rake face; flank face; CUTTING TEMPERATURE; FLANK TEMPERATURE; TOOL WEAR;
D O I
10.4028/www.scientific.net/AMM.668-669.969
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
A method is described to measure temperature on rake face and flank face during high speed milling through the combination of using a non-contact infrared pyrometer and drilling two holes in the workpiece. One of the holes was vertical to the direction of feed for measuring the temperature of rake face, and the other was parallel to the direction of feed for measuring the temperature of flank face. The holes enabled probe beam of the pyrometer to go through them to reach the tool surface directly. The method avoids drilling any hole in the tool and can be used to measure the interface temperature directly. This technique has potential application in monitoring tool temperature and analyzing tool wear during machining of difficult-to-cut materials.
引用
收藏
页码:969 / +
页数:2
相关论文
共 50 条
  • [21] A novel, high resolution, non-contact channel temperature measurement technique
    Kim, Q
    Stark, B
    Kayali, S
    1998 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM PROCEEDINGS - 36TH ANNUAL, 1998, : 108 - 112
  • [22] A micro sensor for non-contact temperature measurement
    Li, XP
    Chan, WF
    MICROMACHINING AND MICROFABRICATION, 2000, 4230 : 66 - 75
  • [23] NON-CONTACT SPEED MEASUREMENT - COMPARISON OF OPTICAL SYSTEMS
    FRITSCHE, R
    MESCH, F
    MEASUREMENT AND CONTROL, 1973, 6 (07): : 293 - 300
  • [24] Non-contact temperature measurement by laser technology
    Huang, Fang
    Liu, Xiangxin
    Han, Junfeng
    Wang, Jing
    Li, Hui
    Wang, Wenjing
    Zhenkong Kexue yu Jishu Xuebao/Journal of Vacuum Science and Technology, 2013, 33 (07): : 642 - 646
  • [25] Reduction of uncertainty with non-contact measurement of temperature
    Zakharenko, V. A.
    Veprikova, Ya R.
    Ponomarev, D. B.
    XII INTERNATIONAL SCIENTIFIC AND TECHNICAL CONFERENCE APPLIED MECHANICS AND SYSTEMS DYNAMICS, 2019, 1210
  • [26] High temperature flexural ultrasonic transducer for non-contact measurement applications
    Burrows, S. E.
    Ramadas, S. N.
    Eriksson, T. J. R.
    Kang, L.
    Dixon, S. M.
    Unger, A.
    Kupnik, M.
    2016 JOINT IEEE INTERNATIONAL SYMPOSIUM ON THE APPLICATIONS OF FERROELECTRICS, EUROPEAN CONFERENCE ON APPLICATION OF POLAR DIELECTRICS, AND PIEZOELECTRIC FORCE MICROSCOPY WORKSHOP (ISAF/ECAPD/PFM), 2016,
  • [27] High Accuracy and Wide Temperature Measurement by Non-Contact Speckle Extensometer
    Kobayashi, K.
    Yamaguchi, I.
    STRAIN, 2011, 47 : E98 - E103
  • [28] Non-contact temperature measurement in embedded applications
    Ibrahim, Dogan
    ELECTRONICS WORLD, 2017, 123 (1971): : 14 - 16
  • [29] Comparison of Non-contact Infrared Temperature with Digital Axillary Temperature
    Varghese Abraham
    Elizabeth Johnson
    Khristina Deep
    Indian Pediatrics, 2018, 55 : 609 - 610
  • [30] Comparison of Non-contact Infrared Temperature with Digital Axillary Temperature
    Abraham, Varghese
    Johnson, Elizabeth
    Deep, Khristina
    INDIAN PEDIATRICS, 2018, 55 (07) : 609 - 610