Liquid chromatographic-electrospray mass spectrometric determination of cyclosporin A in human plasma

被引:11
|
作者
Zaater, MF [1 ]
Tahboub, YR
Najib, NM
机构
[1] Jordan Univ Sci & Technol, Dept Appl Chem, Irbid 22110, Jordan
[2] IPRC, Amman, Jordan
关键词
cyclosporin A; cyclosporin B; LC-MS; human plasma;
D O I
10.1007/s00216-005-3196-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive and selective liquid chromatography-mass spectrometry (LC-MS) assay has been developed for determination of cyclosporin A (CyA) in human plasma; cyclosporin B (CyB) was used as internal standard (IS). The method utilized a combination of a column-switching valve and a reversed-phase symmetry column. The mobile phase was a 25: 75 (v/v) mixture of 10% aqueous glacial acetic acid and acetonitrile. Running time per single run was less than 10 min. Sample preparation included C-8 SPE of human plasma spiked with the analyte and internal standard, evaporation of the eluate to dryness at 50 degrees C under N-2 gas, and finally reconstitution in the mobile phase. Detection of cyclosporin A and the IS was performed in selected ion-monitoring mode at m/z 601.3 and 594.4 Da for CyA and IS, respectively. Quantitation was achieved by use of the regression equation of relative peak area of cyclosporin to IS against concentration of cyclosporin. The method was validated according to FDA guideline requirements. The linearity of the assay in the range 5.0-400.0 ng mL(-1) was verified as characterized by the least-squares regression line Y = (0.00268 +/- 1.9 x 10(-4)) X + (0.00078 +/- 1.8 x 10(-3)), correlation coefficient, r = 0.9986 +/- 1.1 x 10(-3) (n = 48). Intra and inter-day quality-control measurements in the range 5.0-350.0 ng mL(-1) revealed almost 100% accuracy and <= 9% CV for precision. The mean absolute recovery of CyA was found to be 84.01 +/- 9.9% and the respective relative recovery was 100.3 +/- 9.19. The limit of quantitation (LOQ) achieved was 5 ng mL(-1). Eventually, stability testing of the analyte and IS in plasma or stock solution revealed that both chemicals were very stable when stored for long or short periods of time at room temperature or -20 degrees C.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [1] Liquid chromatographic–electrospray mass spectrometric determination of cyclosporin A in human plasma
    M. F. Zaater
    Y. R. Tahboub
    N. M. Najib
    Analytical and Bioanalytical Chemistry, 2005, 382 : 223 - 230
  • [2] Liquid chromatographic-electrospray tandem mass spectrometric determination of bisoprolol in human plasma
    Liu, Mingyuan
    Zhang, Dan
    Sun, Yantong
    Wang, Yingwu
    Liu, Zeyuan
    Gu, Jingkai
    BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (05) : 508 - 513
  • [3] Liquid chromatographic-electrospray tandem mass spectrometric determination of clarithromycin in human plasma
    Li, Wenkui
    Rettig, Joan
    Jiang, Xiangyu
    Francisco, Diane T.
    Weng Naidong
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (11) : 1242 - 1251
  • [4] Determination of gestrinone in human serum by liquid chromatographic-electrospray tandem mass spectrometry
    Li, G
    Wang, QQ
    Wang, YM
    Luo, G
    Wu, EN
    Gao, XF
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 29 (07) : 745 - 749
  • [5] Determination of levonorgestrel in human serum by liquid chromatographic-electrospray tandem mass spectrometry
    Wang, QG
    Wu, ZP
    Wang, YM
    Luo, G
    Wu, ER
    Gao, XF
    Li, G
    ANALYTICAL LETTERS, 2001, 34 (01) : 103 - 112
  • [6] Rapid, simple, specific liquid chromatographic-electrospray mass spectrometry method for the determination of glibenclamide in human plasma
    Chen, BM
    Liang, YZ
    Guo, FQ
    Huang, LF
    Deng, FL
    Chen, X
    Wang, YL
    ANALYTICA CHIMICA ACTA, 2004, 514 (02) : 185 - 191
  • [7] Enantioselective liquid chromatographic-electrospray mass spectrometric assay of β-adrenergic blockers:: application to a pharmacokinetic study of sotalol in human plasma
    Badaloni, E
    D'Acquarica, I
    Gasparrini, F
    Lalli, S
    Misiti, D
    Pazzucconi, F
    Sirtori, CR
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 796 (01): : 45 - 54
  • [8] Liquid chromatographic-electrospray ionization mass spectrometric quantitative analysis of buprenorphine, norbuprenorphine, nordiazepam and oxazepam in rat plasma
    Pirnay, S
    Herve, F
    Bouchonnet, S
    Perrin, B
    Baud, FJ
    Ricordel, I
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (04) : 1135 - 1145
  • [9] Liquid chromatographic-electrospray ionization mass spectrometric analysis of neutral and charged polyethylene glycols
    Palmgrén, JJ
    Toropainen, E
    Auriola, S
    Urtti, A
    JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) : 165 - 170
  • [10] Determination of 3′-C-ethynylcytidine in human plasma and urine by liquid chromatographic-electrospray ionization tandem mass spectrometry
    Matsuoka, K
    Kitamura, R
    Matsushima, E
    Kawaguchi, Y
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (01) : 47 - 55