Percutaneous MR Imaging-Guided Cryoablation of Small Renal Masses in a 3-T Closed-Bore MR Imaging Environment: Initial Experience

被引:8
|
作者
van Oostenbrugge, Tim J. [1 ,2 ]
Langenhuijsen, Johan F. [2 ]
Overduin, Christiaan G. [1 ]
Jenniskens, Sjoerd F. [1 ]
Mulders, Peter F. A. [2 ]
Futterer, Jurgen J. [1 ,3 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, POB 9101, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Urol, POB 9101, NL-6500 HB Nijmegen, Netherlands
[3] Univ Twente, Inst Biomed Technol & Tech Med, Enschede, Netherlands
关键词
CELL CARCINOMA; ICE-BALL; TUMORS; COMPLICATIONS; RADIOFREQUENCY; CRYOTHERAPY; ABLATION; SEQUENCE; OUTCOMES; SYSTEM;
D O I
10.1016/j.jvir.2017.05.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of percutaneous magnetic resonance (MR) imaging-guided cryoablation of small renal masses (SRMs) in a 3-T environment and to evaluate intraprocedural imaging, procedural safety, and initial outcomes. Materials and Methods: The analysis included 9 patients (4 men; median age, 72 y; range, 70-82 y) with 9 SRMs (diameter, 12-30 mm). Lesions underwent biopsy, and cryoneedles were inserted under ultrasound guidance. Verification of needle positions and ice-ball monitoring were performed by T1-weighted volumetric interpolated breath-hold examination and T2-weighted half-Fourier acquired single-shot turbo spin-echo sequences. On image analysis, needle positioning was considered appropriate if the target lesion border was visible, the needle tip was inside the target lesion, and the ice ball was expected to cover the target lesion with a 5-mm margin. If these criteria could not be assessed, imaging was considered inadequate. Technical success was defined as tumor coverage with a 5-mm margin and no residual disease on 1-mo follow-up MR imaging. Results: Median total procedure time was 170 min (range, 135-193 min). Intraoperative imaging allowed adequate needle visualization in 67% of acquired scans (4 of 7 T1-weighted and 6 of 8 T2-weighted). Appropriate positioning of two or three needles used for each procedure was confirmed in all cases on T1- or T2-weighted imaging. Ice-ball formation was adequately visualized in all patients. Technical success rate was 100%. No local recurrences were detected on follow-up imaging at a median of 12 mo (range, 3-22 mo). Conclusions: Percutaneous MR-guided cryoablation of SRMs in a 3-T MR imaging environment is safe and feasible, showing adequate intraoperative imaging capabilities with promising short-term clinical outcomes.
引用
收藏
页码:1098 / 1107
页数:10
相关论文
共 50 条
  • [31] Whole body diffusion weighted imaging by 3T MR in multiple patients: Initial experience
    Pans, S.
    De Keyzer, F.
    Delforge, M.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 (06): : 138 - 138
  • [32] Renal Perfusion 3-T MR Imaging: A Comparative Study of Arterial Spin Labeling and Dynamic Contrast-enhanced Techniques
    Wu, Wen-Chau
    Su, Mao-Yuan
    Chang, Chin-Cheng
    Tseng, Wen-Yih Isaac
    Liu, Kao-Lang
    RADIOLOGY, 2011, 261 (03) : 845 - 853
  • [33] MR Imaging Near Metallic Implants Using MAVRIC SL: Initial Clinical Experience at 3T
    Gutierrez, Luis B.
    Do, Bao H.
    Gold, Garry E.
    Hargreaves, Brian A.
    Koch, Kevin M.
    Worters, Pauline W.
    Stevens, Kathryn J.
    ACADEMIC RADIOLOGY, 2015, 22 (03) : 370 - 379
  • [34] MR Imaging-Guided Intervention: Evaluation of MR Conditional Biopsy and Ablation Needle Tip Artifacts at 3T Using a Balanced Fast Field Echo Sequence
    Singh, Saurabh
    Torrealdea, Francisco
    Bandula, Steve
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 32 (07) : 1068 - +
  • [35] Imaging features of small (≤3 cm) pancreatic solid tumors on gadoxetic-acid-enhanced MR imaging and diffusion-weighted imaging: an initial experience
    Jang, Kyung Mi
    Kim, Seong Hyun
    Kim, Young Kon
    Park, Min Jung
    Lee, Mi Hee
    Hwang, Jiyoung
    Rhim, Hyunchul
    MAGNETIC RESONANCE IMAGING, 2012, 30 (07) : 916 - 925
  • [36] MR Spectroscopic Imaging of Benign Prostatic Tissue: Findings at 3T Compared to 1.5T Initial Experience
    Chitkara, M.
    Westphalen, A.
    Kurhanewicz, J.
    Qayyum, A.
    Poder, L.
    Reed, G.
    Coakley, F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05)
  • [37] Low Injection Rate for 3D Moving-Table Bolus-Chase MR Angiography: Initial Experience with 3-T Imaging to Allay Venous Contamination in the Calf
    Lin, Kai
    Zhang, Zhao-Qi
    Sun, Jun-Yan
    Fan, Zhan-Ming
    Lu, Biao
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) : 1734 - 1739
  • [38] Hyperkalemic Periodic Paralysis and Permanent Weakness: 3-T MR Imaging Depicts Intracellular 23Na Overload-Initial Results
    Amarteifio, Erick
    Nagel, Armin M.
    Weber, Marc-Andre
    Jurkat-Rott, Karin
    Lehmann-Horn, Frank
    RADIOLOGY, 2012, 264 (01) : 154 - 163
  • [39] Low-flow vascular malformations in the head and neck: Safety and feasibility of MR imaging-guided percutaneous sclerotherapy - Preliminary experience with 14 procedures in three patients
    Lewin, JS
    Merkle, EM
    Duerk, JL
    Tarr, RW
    RADIOLOGY, 1999, 211 (02) : 566 - 570
  • [40] Segmented diffusion-weighted imaging of the prostate: Application to transperineal in-bore 3 T MR image-guided targeted biopsy
    Fedorov, Andriy
    Tuncali, Kemal
    Panych, Lawrence P.
    Fairhurst, Janice
    Hassanzadeh, Elmira
    Seethamraju, Ravi T.
    Tempany, Clare M.
    Maier, Stephan E.
    MAGNETIC RESONANCE IMAGING, 2016, 34 (08) : 1146 - 1154