Percutaneous MR Imaging-Guided Cryoablation of Small Renal Masses in a 3-T Closed-Bore MR Imaging Environment: Initial Experience

被引:8
|
作者
van Oostenbrugge, Tim J. [1 ,2 ]
Langenhuijsen, Johan F. [2 ]
Overduin, Christiaan G. [1 ]
Jenniskens, Sjoerd F. [1 ]
Mulders, Peter F. A. [2 ]
Futterer, Jurgen J. [1 ,3 ]
机构
[1] Radboud Univ Nijmegen, Med Ctr, Dept Radiol, POB 9101, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen, Med Ctr, Dept Urol, POB 9101, NL-6500 HB Nijmegen, Netherlands
[3] Univ Twente, Inst Biomed Technol & Tech Med, Enschede, Netherlands
关键词
CELL CARCINOMA; ICE-BALL; TUMORS; COMPLICATIONS; RADIOFREQUENCY; CRYOTHERAPY; ABLATION; SEQUENCE; OUTCOMES; SYSTEM;
D O I
10.1016/j.jvir.2017.05.009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the feasibility of percutaneous magnetic resonance (MR) imaging-guided cryoablation of small renal masses (SRMs) in a 3-T environment and to evaluate intraprocedural imaging, procedural safety, and initial outcomes. Materials and Methods: The analysis included 9 patients (4 men; median age, 72 y; range, 70-82 y) with 9 SRMs (diameter, 12-30 mm). Lesions underwent biopsy, and cryoneedles were inserted under ultrasound guidance. Verification of needle positions and ice-ball monitoring were performed by T1-weighted volumetric interpolated breath-hold examination and T2-weighted half-Fourier acquired single-shot turbo spin-echo sequences. On image analysis, needle positioning was considered appropriate if the target lesion border was visible, the needle tip was inside the target lesion, and the ice ball was expected to cover the target lesion with a 5-mm margin. If these criteria could not be assessed, imaging was considered inadequate. Technical success was defined as tumor coverage with a 5-mm margin and no residual disease on 1-mo follow-up MR imaging. Results: Median total procedure time was 170 min (range, 135-193 min). Intraoperative imaging allowed adequate needle visualization in 67% of acquired scans (4 of 7 T1-weighted and 6 of 8 T2-weighted). Appropriate positioning of two or three needles used for each procedure was confirmed in all cases on T1- or T2-weighted imaging. Ice-ball formation was adequately visualized in all patients. Technical success rate was 100%. No local recurrences were detected on follow-up imaging at a median of 12 mo (range, 3-22 mo). Conclusions: Percutaneous MR-guided cryoablation of SRMs in a 3-T MR imaging environment is safe and feasible, showing adequate intraoperative imaging capabilities with promising short-term clinical outcomes.
引用
收藏
页码:1098 / 1107
页数:10
相关论文
共 50 条
  • [1] MR imaging-guided percutaneous angioplasty and stent placement in a swine model: Comparison of open- and closed-bore scanners
    Wacker, FK
    Hillenbrand, C
    Elgort, DR
    Zhang, SX
    Duerk, JL
    Lewin, JS
    ACADEMIC RADIOLOGY, 2005, 12 (09) : 1085 - 1088
  • [2] Renal tumors: MR imaging-guided percutaneous cryotherapy - Initial experience in 23 patients
    Silverman, SG
    Tuncali, K
    vanSonnenberg, E
    Morrison, PR
    Shankar, S
    Ramaiya, N
    Richie, JP
    RADIOLOGY, 2005, 236 (02) : 716 - 724
  • [3] MR imaging-guided percutaneous cryotherapy of liver tumors: Initial experience
    Silverman, SG
    Tuncali, K
    Adams, DF
    vanSonnenberg, E
    Zou, KH
    Kacher, DF
    Morrison, PR
    Jolesz, FA
    RADIOLOGY, 2000, 217 (03) : 657 - 664
  • [4] MR Imaging-Guided Percutaneous Cryotherapy for Lung Tumors: Initial Experience
    Liu, Shangang
    Ren, Ruimei
    Liu, Ming
    Lv, Yubo
    Li, Bin
    Li, Chengli
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 25 (09) : 1456 - 1462
  • [5] MR imaging-guided cryoablation of metastatic brain tumours: initial experience in six patients
    Li, Chengli
    Wu, Lebin
    Song, Jiqing
    Liu, Ming
    Lv, Yubo
    Sequeiros, Roberto Blanco
    EUROPEAN RADIOLOGY, 2010, 20 (02) : 404 - 409
  • [6] MR imaging-guided cryoablation of metastatic brain tumours: initial experience in six patients
    Chengli Li
    Lebin Wu
    Jiqing Song
    Ming Liu
    Yubo Lv
    Roberto Blanco Sequeiros
    European Radiology, 2010, 20 : 404 - 409
  • [7] MR imaging-guided prostate biopsy with a closed MR unit at 1.5 T: Initial results
    Beyersdorff, D
    Winkel, A
    Hamm, B
    Lenk, S
    Loening, SA
    Taupitz, M
    RADIOLOGY, 2005, 234 (02) : 576 - 581
  • [8] Transperineal In-Bore 3-T MR Imaging-guided Prostate Biopsy: A Prospective Clinical Observational Study
    Penzkofer, Tobias
    Tuncali, Kemal
    Fedorov, Andriy
    Song, Sang-Eun
    Tokuda, Junichi
    Fennessy, Fiona M.
    Vangel, Mark G.
    Kibel, Adam S.
    Mulkern, Robert V.
    Wells, William M.
    Hata, Nobuhiko
    Tempany, Clare M. C.
    RADIOLOGY, 2015, 274 (01) : 170 - 180
  • [9] Targeted-HASTE imaging with automated device tracking for MR-guided needle interventions in closed-bore MR systems
    Zimmermann, H.
    Mueller, S.
    Gutmann, B.
    Bardenheuer, H.
    Melzer, A.
    Umathum, R.
    Nitz, W.
    Semmler, W.
    Bock, M.
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (03) : 481 - 488
  • [10] MR imaging of the wrist:: Comparison between 1.5-and 3-T MR imaging -: Preliminary experience
    Saupe, N
    Pruessmann, KP
    Luechinger, R
    Bösiger, P
    Marincek, B
    Weishaupt, D
    RADIOLOGY, 2005, 234 (01) : 256 - 264