摘要
Species-specific isotope dilution analysis (IDA) has been used to determine the mass fraction of methylmercury in a fish muscle certified reference material, DORM-2. Two spike solutions were prepared and their mass fractions determined by coupling high-performance liquid chromatography (HPLC) with both quadrupole (Q) and multicollector (MC) inductively coupled plasma mass spectrometry (ICP-MS) and uncertainty budgets calculated. For the Q-ICP-MS determination the relative standard uncertainty of the spike was 4.1%. The major uncertainty contribution (62%) arose from the uncertainties associated with the relative isotopic abundances of Hg isotopes as given by IUPAC. The measured isotope amount ratios (Hg-200:Hg-199 and Tl-205:Tl-203) contributed 37% of the combined uncertainty. For the multicollector instrument the relative standard uncertainty of the spike solution mass fraction was 0.7%. In this case the uncertainty budget was dominated by the Hg isotopic uncertainties, with a contribution of 99%. The uncertainty contributions from the measured isotope amount ratios were reduced to 0.7% of the total when using MC-ICP-MS. The two spike solutions were separately used to determine the mass fraction of methylmercury in DORM-2 CRM by species-specific IDA, using HPLC coupled with quadrupole ICP-MS. The values found were 4.45 +/- 0.90 mug g(-1) and 4.25 +/- 0.47 mug g(-1) using spikes characterised by Q- and MC-ICP-MS, respectively (the uncertainties quoted are the expanded uncertainty, k = 2), compared with a certified value of 4.47 +/- 0.32. The major uncertainty contribution for each determination was from the measured isotope amount ratios (70%) with lesser contributions from the uncertainties associated with the natural isotopic abundance of Hg and the spike mass fraction.
引用
收藏
页码:1039 / 1046
页数:8
相关论文
共 28 条
  • [21] Determination of free methionine in human blood plasma by species-specific isotope dilution HPLC-ICP-MS using 34S-labelled methionine
    Galilea San Blas, Oscar
    Moreno Sanz, F.
    Herrero Espilez, P.
    Prieto Garcia, Belen
    Alvarez Menendez, Francisco V.
    Manuel Marchante-Gayon, Juan
    Garcia Alonso, Jose Ignacio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2016, 31 (09) : 1885 - 1894
  • [22] Ultra-trace speciation analysis of Cr(III) and Cr(VI) in rice using species-specific isotope dilution and HPLC-ICP-MS
    Saraiva, Marina
    Guerin, Thierry
    Jitaru, Petru
    Sloth, Jens J.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2021, 38 (10): : 1735 - 1742
  • [23] Determination of methylmercury, ethylmercury, and inorganic mercury in mouse tissues, following administration of thimerosal, by species-specific isotope dilution GC-inductively coupled plasma-MS
    Qvarnström, J
    Lambertsson, L
    Havarinasab, S
    Hultman, P
    Frech, W
    ANALYTICAL CHEMISTRY, 2003, 75 (16) : 4120 - 4124
  • [24] Quantification of a selenium-containing protein in yeast extract via an accurate determination of a tryptic peptide by species-specific isotope dilution capillary HPLC-ICP MS
    Polatajko, A
    Encinar, JR
    Schaumlöffel, D
    Szpunar, J
    CHEMIA ANALITYCZNA, 2005, 50 (01): : 265 - 278
  • [25] Comparison of GC-ICP-MS, GC-EI-MS and GC-EI-MS/MS for the determination of methylmercury, ethylmercury and inorganic mercury in biological samples by triple spike species-specific isotope dilution mass spectrometry
    Suarez-Criado, Laura
    Queipo-Abad, Silvia
    Rodriguez-Cea, Andres
    Rodriguez-Gonzalez, Pablo
    Garcia Alonso, J. Ignacio
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2022, 37 (07) : 1462 - 1470
  • [26] Development and validation of a single run method based on species specific isotope dilution and HPLC-ICP-MS for simultaneous species interconversion correction and speciation analysis of Cr(III)/Cr(VI) in meat and dairy products
    Saraiva, Marina
    Chekri, Rachida
    Leufroy, Axelle
    Guerin, Thierry
    Sloth, Jens J.
    Jitaru, Petru
    TALANTA, 2021, 222
  • [27] Determination of artifactual formation of monomethylmercury (CH3Hg+) in environmental samples using stable Hg2+ isotopes with ICP-MS detection: Calculation of contents applying species specific isotope addition
    H. Hintelmann
    R. Falter
    G. Ilgen
    R. D. Evans
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 363 - 370
  • [28] Determination of artifactual formation of monomethylmercury (CH3Hg+) in environmental samples using stable Hg2+ isotopes with ICP-MS detection: Calculation of contents applying species specific isotope addition
    Hintelmann, H
    Falter, R
    Ilgen, G
    Evans, RD
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (03): : 363 - 370