Measurement of force and pressure distribution in walking for prosthesis design

被引:0
|
作者
Magni, Marianna [1 ]
Saggin, Bortolino [1 ]
Scaccabarozzi, Diego [1 ]
Tarabini, Marco [1 ]
机构
[1] Politecn Milan, Dept Mech Engn, Milan, Italy
关键词
prostheses; PedarX; pressure maps; gait analysis; ANKLE;
D O I
暂无
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
This work deals with measurement of the force and pressure distribution during walking of a patient with both feet not fully formed. Patient' legs are completely formed down to the heels and the beginning of one midfoot. Since the forefoot is missing, the subject has a difficult propulsion during the boost phase and an excessive rotation at the ankle due to an absent malleolar stability. Design of a customized prosthesis, conceived to ease the subject movement, required the measurement of the forces and pressure distributions during movement. In fact, existing trans-tibial and trans-femoral prostheses studies cannot be applied given that the patient has a limited ankle mobility that shall be preserved during the movement. The force and pressure distributions, measured by means of a commercial measurement system based on capacitive sensors, have been used as input for the finite elements based design. Models of the prostheses have been developed and the performed finite element analyses validated the preliminary design, allowing the manufacturing of prosthetic prototypes.
引用
收藏
页码:557 / 562
页数:6
相关论文
共 50 条
  • [31] Enhancing the Accuracy of Vertical Ground Reaction Force Measurement During Walking Using Pressure-Measuring Insoles
    DeBerardinis, Jessica
    Trabia, Mohamed B.
    Dufek, Janet S.
    Le Gall, Yann
    Sacoto, Nicolas Da Silva
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (01):
  • [32] The efficacy of physiological cost index (PCT) measurement of a subject walking with an Intelligent Prosthesis
    Chin, T
    Sawamura, S
    Fujita, H
    Nakajima, S
    Ojima, I
    Oyabu, H
    Nagakura, Y
    Otsuka, H
    Nakagawa, A
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1999, 23 (01) : 45 - 49
  • [33] Assessment of the User Interface of Walking Aids: Force measurement at the Handle
    Koscielniak, L.
    Huebner, U.
    Staemmler, M.
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S428 - S428
  • [34] Design of force measurement module for force touch screens
    Lee, Yong-Min
    Lee, Sangjoon
    IEICE ELECTRONICS EXPRESS, 2017, 14 (20):
  • [35] Force-directed design of a voluntary closing hand prosthesis
    de Visser, H
    Herder, JL
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2000, 37 (03): : 261 - 271
  • [36] Influences of walking speed change on the lumbosacral joint force distribution
    Cheng, CK
    Chen, HH
    Chen, CS
    Lee, SJ
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1998, 8 (3-4) : 155 - 165
  • [37] Implantable autonomous device for wireless force measurement in total knee prosthesis
    Khan M.A.
    Borghetti M.
    Serpelloni M.
    Sardini E.
    IEEE Instrumentation and Measurement Magazine, 2019, 22 (01): : 39 - 47
  • [38] Implantable Autonomous Device for Wireless Force Measurement in Total Knee Prosthesis
    Khan, Muhammad Ahmed
    Borghetti, Michela
    Serpelloni, Mauro
    Sardini, Emilio
    IEEE INSTRUMENTATION & MEASUREMENT MAGAZINE, 2019, 22 (01) : 39 - 47
  • [39] Optimal force distribution for quadruped walking robots with a failed leg
    Trans. Korean Inst. Electr. Eng., 2009, 3 (614-620):
  • [40] FOOT FORCE DISTRIBUTION OF WALKING MACHINE WITH CONSIDERATION OF TERRAIN PROPERTIES
    ZHENG, CQ
    SONG, SM
    WIDERA, GEO
    JOURNAL OF TERRAMECHANICS, 1992, 29 (4-5) : 497 - 514