Soft contact lens polymers: an evolution

被引:549
|
作者
Nicolson, PC [1 ]
Vogt, J [1 ]
机构
[1] CIBA Vis Corp, Lens Business Unit Res & Dev, Duluth, GA 30097 USA
关键词
contact lens; polymer; hydrogels; siloxane hydrogels; phases; macromer;
D O I
10.1016/S0142-9612(01)00165-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A review of patents and literature reveals an evolution in materials technologies. The evolution has been driven by an increased understanding of the physiological needs of the cornea, beginning with the first hydrogel lenses developed by Wichterle, followed by a variety of high water hydrogels. Oxygen transmission requirements have been addressed through the use of siloxane and fluorosiloxane containing hydrogels. An important development has been the appreciation of the importance of polymer phase morphology on lens movement on the eye. In parallel with these activities have come the advancements in materials suitable to high volume, low cost production necessary for today's daily disposable lenses. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:3273 / 3283
页数:11
相关论文
共 50 条
  • [21] Modeling the vertical motion of a soft contact lens
    Chauhan, A
    Radke, CJ
    [J]. CURRENT EYE RESEARCH, 2001, 22 (02) : 102 - 108
  • [22] Evaluation of soft contact lens fitting characteristics
    Young, G
    [J]. OPTOMETRY AND VISION SCIENCE, 1996, 73 (04) : 247 - 254
  • [23] Simplified recording of soft contact lens fit
    Wolffsohn, James S.
    Hunt, Olivia A.
    Basra, Amritpreet K.
    [J]. CONTACT LENS & ANTERIOR EYE, 2009, 32 (01): : 37 - 42
  • [24] Chromatic dispersion of soft contact lens materials
    Spychala, Beate
    Ehrmann, Klaus
    [J]. CONTACT LENS & ANTERIOR EYE, 2023, 46 (04):
  • [25] FUNGAL INVASION OF A SOFT CONTACT-LENS
    SAGAN, W
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1976, 94 (01) : 168 - 168
  • [26] Soft contact lens fitted with microchip and antenna
    Johnston, Hamish
    [J]. PHYSICS WORLD, 2019, 32 (01) : 5 - 5
  • [27] Settling and deformation of a soft contact lens.
    Chauhan, A
    Radke, C
    Polse, K
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S589 - S589
  • [28] The conjunctival sensitivity in soft contact lens wearers
    Tsutomu Igarashi
    Masafumi Ono
    Chiaki Fujimoto
    Hisaharu Suzuki
    Hiroshi Takahashi
    [J]. International Ophthalmology, 2015, 35 : 569 - 573
  • [29] SOFT SILICON RUBBER CORNEAL CONTACT LENS
    LONG, W
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1970, 47 (11): : 915 - &
  • [30] SOLVING SOFT CONTACT-LENS PROBLEMS
    DRIEBE, WT
    RABELL, CG
    HOUDE, WL
    [J]. SURVEY OF OPHTHALMOLOGY, 1983, 27 (04) : 259 - 263