Research on the Analytical Model of Improved Magnetic Flux Leakage Signal for the Local Stress Concentration Zone of Pipelines

被引:5
|
作者
Yang, Lijian [1 ]
Zheng, Fuyin [1 ]
Huang, Ping [1 ]
Bai, Shi [1 ]
Su, Yuming [1 ]
机构
[1] Shenyang Univ Technol, Coll Informat Sci & Engn, Shenyang 110870, Peoples R China
基金
中国国家自然科学基金;
关键词
local stress concentration; magnetomechanical model; analytical model; MFL signal;
D O I
10.3390/s22031128
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Local stress concentrations pose a significant hazard to the safe operation of pipelines. However, the classical analytical model of the magnetic flux leakage (MFL) signal is still unable to effectively quantitatively analyze and accurately evaluate the local stress concentration zone of a pipeline. In this paper, based on the Jiles-Atherton model of the magnetomechanical effect, the mathematical relationship between stress and the magnetization of ferromagnetic material under hysteresis conditions is introduced, and an improved analytical model of the MFL signal based on the magnetomechanical model is established. The influence law of stress intensity on the MFL signal in the local stress concentration zone of the pipeline is calculated and analyzed, and the theoretical calculation results are verified through experiments. Simulation and experimental results show that, considering the hysteresis condition, the stress causes a change in the hysteresis loop of the ferromagnetic material, and the magnetization strength of the material decreases with increasing stress; the effect of stress on the magnetization strength of ferromagnetic materials is most obvious when the external magnetic field is approximately 5 KA/m. The MFL signal on the surface of the local stress concentration zone of the pipe changes abruptly, and the amount of change in the axial amplitude and radial peak-to-peak value of the leakage signal of the pipe tends to increase with the increase in the stress intensity of the local stress concentration zone. A comparison of the analysis with the classical analytical model of the MFL signal shows that the improved analytical model of the MFL signal is more suitable for the quantification study of the local stress concentration zone of the pipeline.
引用
收藏
页数:21
相关论文
共 48 条
  • [41] A magneto-mechanical coupling constitutive model for self-magnetic flux leakage stress detection in ferromagnetic materials
    Zeng, Shaoxi
    Li, Hongmei
    Zhao, Chuntian
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2025, 618
  • [42] Research on the Forward Solving Method of Defect Leakage Signal Based on the Non-Uniform Magnetic Charge Model
    Gao, Pengfei
    Geng, Hao
    Yang, Lijian
    Su, Yuming
    SENSORS, 2023, 23 (13)
  • [43] Fatigue life analysis of hydropower pipelines using the analytical model of stress concentration in welded joints with angular distortions and considering the influence of water hammer damping
    Adamkowski, Adam
    Lewandowski, Mariusz
    Lewandowski, Stanislaw
    THIN-WALLED STRUCTURES, 2021, 159
  • [44] A Fast 3D Semi-Analytical Model for Simulating Flaw Responses Provided by a Magnetic Flux Leakage NDT System Inspecting Ferromagnetic Pipes
    Trillon, Adrien
    Deneuville, Francois
    Premel, Denis
    Djafa, Steve
    Pichon, Lionel
    40TH ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 10TH INTERNATIONAL CONFERENCE ON BARKHAUSEN NOISE AND MICROMAGNETIC TESTING, VOLS 33A & 33B, 2014, 1581 : 1421 - 1427
  • [45] Analytical calculation of magnetic field of dual-winding bearingless flux-switching permanent magnet motors based on improved subdomain model
    Cui Z.-S.
    Zhou Y.-Z.
    Zhou Y.-H.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (03): : 66 - 77
  • [46] Analytical Model of Air-Gap Magnetic Field of Slotted Axial Flux Permanent Magnet Motor Based on Improved Complex Relative Permeance Function
    Tong, Wenming
    Du, Shaoyu
    Jia, Jianguo
    Huang, Rui
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2024, 39 (24): : 7700 - 7711
  • [47] Theoretical model of magneto-elastoplastic coupling for micro-magnetic non-destructive testing method with stress concentration and plastic zone
    Shi P.
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2021, 53 (12): : 3341 - 3353
  • [48] Evaluation of Original and Water Stress-Incorporated Modified Weather Research and Forecasting Vegetation Photosynthesis and Respiration Model in Simulating CO2 Flux and Concentration Variability over the Tibetan Plateau
    Niu, Hanlin
    Hu, Xiao-Ming
    Shang, Lunyu
    Meng, Xianhong
    Wang, Shaoying
    Li, Zhaoguo
    Zhao, Lin
    Chen, Hao
    Deng, Mingshan
    Sheng, Danrui
    REMOTE SENSING, 2023, 15 (23)