Fabrication of reusable sensor for detection of Cu2+ in an aqueous solution using a self-assembled monolayer with surface plasmon resonance spectroscopy

被引:31
|
作者
Kang, T [1 ]
Hong, SR [1 ]
Moon, J [1 ]
Oh, S [1 ]
Yi, J [1 ]
机构
[1] Seoul Natl Univ, Sch Chem & Biol Engn, Seoul, South Korea
关键词
D O I
10.1039/b504064g
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The proposed procedure for recycling the sensor surface consists of (1) the self-assembly of 2-aminoethanethiol hydrochloride (AET) on the Au substrate, (2) the neutralization of zwitterion-like species, -NH3+Cl- to -NH2 by treatment with a NaOH solution (pH 11), (3) the detection of Cu2+ on the NaOH-treated AET-Au substrate, and finally (4) regeneration of the sensor surface from [-NH2 -> Cu2+] to [-NH3+Cl-] by treatment with 1 M HCl.
引用
收藏
页码:3721 / 3723
页数:3
相关论文
共 50 条
  • [31] Surface plasmon resonance detection of endocrine disruptors using immunoprobes based on self-assembled monolayers
    Gobi, KV
    Kataoka, C
    Miura, N
    SENSORS AND ACTUATORS B-CHEMICAL, 2005, 108 (1-2): : 784 - 790
  • [32] Cholesterol biosensor based on amino-undecanethiol self-assembled monolayer using surface plasmon resonance technique
    Solanki, Pratima R.
    Arya, Sunil K.
    Nishimura, Y.
    Iwamoto, M.
    Malhotra, B. D.
    LANGMUIR, 2007, 23 (13) : 7398 - 7403
  • [33] Surface plasmon resonance immunosensor for human cardiac troponin T based on self-assembled monolayer
    Dutra, Rosa Fireman
    Mendes, Renata Kelly
    da Silva, Valdinete Lins
    Kubota, Lauro Tatsuo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (05) : 1744 - 1750
  • [34] Photoinduced refractive index change of self-assembled spiroxazaine monolayer based on surface plasmon resonance
    Kim, SH
    Ock, KS
    Im, JH
    Kim, JH
    Koh, KN
    Kang, SW
    DYES AND PIGMENTS, 2000, 46 (01) : 55 - 62
  • [35] Surface plasmon resonance measurement of pyridoxal kinase-pyridoxamine binding on self-assembled monolayer
    Yau, HCM
    Wu, SY
    Ho, HP
    Yang, MS
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 85 (03) : 227 - 231
  • [36] Application of octadecanethiol self-assembled monolayer to cholesterol biosensor based on surface plasmon resonance technique
    Arya, Sunil K.
    Solanki, Pratima R.
    Singh, Ravindra P.
    Pandey, Manoj K.
    Datta, Monika
    Malhotra, Bansi D.
    TALANTA, 2006, 69 (04) : 918 - 926
  • [37] Using surface plasmon resonance spectroscopy to measure the association of detergents with self-assembled monolayers of hexadecanethiolate on gold
    Sigal, GB
    Mrksich, M
    Whitesides, GM
    LANGMUIR, 1997, 13 (10) : 2749 - 2755
  • [38] Fabrication of surface energy/chemical gradients using self-assembled monolayer surfaces
    Meyyappan, S.
    Shadnam, M. R.
    Amirfazli, A.
    LANGMUIR, 2008, 24 (06) : 2892 - 2899
  • [39] A glucose-selective surface plasmon resonance sensor based on self-assembled multilayers
    Yang Xiao-Hai
    Li Zhen-Hua
    Wang Qing
    Wang Ke-Min
    ACTA CHIMICA SINICA, 2007, 65 (12) : 1185 - 1189
  • [40] Significantly enhanced sensitivity of surface plasmon resonance sensor with self-assembled metallic nanoparticles
    Kim, Hong-Seung
    Lee, Byeong-Hyeon
    Oh, Geum-Yoon
    Lee, Tae-Kyeong
    Kim, Doo-Gun
    Kim, Tae-Ryong
    Choi, Young-Wan
    JOURNAL OF NANOPHOTONICS, 2016, 10 (02)