Seismic vulnerability assessment of precast post-tensioned segmental bridge piers subject to far-fault ground motions

被引:14
|
作者
Ahmadi, Ehsan [1 ]
Kashani, Mohammad M. [2 ]
机构
[1] Birmingham City Univ, Sch Engn & Built Environm, Birmingham, W Midlands, England
[2] Univ Southampton, Fac Engn & Phys Sci, Southampton, Hants, England
基金
英国工程与自然科学研究理事会;
关键词
Precast post-tensioned segmental columns; Accelerated bridge construction; Incremental dynamic analysis; Far-fault ground motions; Seismic performance assessment; RIGID BLOCKS; ROCKING INSTABILITY; REINFORCING BARS; BASE EXCITATION; COLUMNS; PERFORMANCE; CORROSION; BODIES; IMPACT; FRAMES;
D O I
10.1016/j.istruc.2021.09.041
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Precast post-tensioned segmental (PPS) bridge piers mitigate global and local damages of bridge structures through natural hinges (joints between their segments) and rocking motion of their segments. The application of the PPS piers is currently growing in Accelerated Bridge Construction (ABC) where the segments are manufactured offsite with higher quality, and are assembled onsite in a short time. Structural vulnerability analysis of the PPS piers is very essential in extending their engineering implementation under seismic loading. Thus, this work particularly focuses on seismic vulnerability assessment of the PPS piers. To achieve this goal, a previously developed and experimentally validated robust Finite Element model of the PPS piers in OpenSees programme is used to analyse PPS piers of various aspect ratios. An equivalent reinforced concrete (RC) pier to one of the PPS piers is also analysed. Incremental Dynamic Analysis (IDA) is performed and fragility curves are generated to evaluate seismic performance of the PPS piers and an equivalent RC pier using a suite of 44 far-fault ground motions. The IDA results show that slenderising the PPS pier tends to change the failure criterion from the yielding of the post-tensioning tendon to the strength loss of the pier. For squat and slender piers, the yielding of the tendon governs the failure of the pier while the strength of very slender PPS piers drops due to second-order effects at small drift values prior to the yielding of the post-tensioning tendon. It is also found from fragility curves that squat piers are more prone to seismic collapse compared to slender piers. The equivalent RC pier reaches slight and medium damage states in lower intensity measures compared to the PPS pier.
引用
收藏
页码:2566 / 2579
页数:14
相关论文
共 50 条
  • [21] Modal parameter identification and seismic assessment of historical timber structures under near-fault and far-fault ground motions
    Altunisik, Ahmet Can
    Sunca, Fezayil
    Sevim, Baris
    STRUCTURES, 2023, 47 : 1624 - 1651
  • [22] An explicit analytical model for seismic performance of an unbonded post-tensioned precast segmental rocking hollow pier
    Wang, Zhen
    Wang, Jing-Quan
    Liu, Tong-Xu
    Zhang, Jian
    ENGINEERING STRUCTURES, 2018, 161 : 176 - 191
  • [23] Performance-based seismic design of unbonded precast post-tensioned concrete filled GFRP tube piers
    Dawood, Haitham M.
    ElGawady, Mohamed
    COMPOSITES PART B-ENGINEERING, 2013, 44 (01) : 357 - 367
  • [24] Post-Earthquake Damage Assessments of Historic Mosques and Effects of Near-Fault and Far-Fault Ground Motions on Seismic Responses
    Altunisik, Ahmet Can
    Sunca, Fezayil
    Genc, Ali Fuat
    Tavsan, Cengiz
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2023, 17 (07) : 1043 - 1078
  • [25] Failure analysis of one-story precast structures for near-fault and far-fault strong ground motions
    E. Yüksel
    M. Sürmeli
    Bulletin of Earthquake Engineering, 2010, 8 : 937 - 953
  • [26] Failure analysis of one-story precast structures for near-fault and far-fault strong ground motions
    Yuksel, E.
    Surmeli, M.
    BULLETIN OF EARTHQUAKE ENGINEERING, 2010, 8 (04) : 937 - 953
  • [27] Vulnerability Assessment of Precast Segmental RC Bridge Piers Under Near-field Explosion
    Liu L.
    Zong Z.-H.
    Zhou H.-F.
    Chen Z.-J.
    Tang G.-W.
    Zhongguo Gonglu Xuebao/China Journal of Highway and Transport, 2024, 37 (04): : 212 - 223
  • [28] Probabilistic seismic performance evaluation of nuclear containment structure subjected to far-fault ground motions
    Jin, Song
    Rong, Hua
    Lyu, Xuetao
    STRUCTURES, 2021, 32 : 2232 - 2246
  • [29] Seismic performance-based assessment of tunnel form building subjected to near- and far-fault ground motions
    Behesthi Aval S.B.
    Mohsenian V.
    Sadegh Kouhestani H.
    Asian Journal of Civil Engineering, 2018, 19 (1) : 79 - 92
  • [30] Structural design of self-centering socket precast post-tensioned segmental (SSPPS) bridge piers reinforced with BFRP tendons and stainless energy dissipation bars
    Li, Zongao
    Chen, Weiyi
    Wu, Bo
    Qian, Hui
    Ye, Chenyang
    Yang, Xin
    Wang, Dongsheng
    STRUCTURES, 2024, 64