Malposition of selective cerebral perfusion catheter is not a rare event

被引:39
|
作者
Orihashi, K [1 ]
Sueda, T [1 ]
Okada, K [1 ]
Imai, K [1 ]
机构
[1] Hiroshima Univ Hosp, Div Cardiovasc Surg, Minami Ku, Hiroshima 7348551, Japan
关键词
selective cerebral malperfusion; aortic arch aneurysm; transesophageal echocardiography; malperfusion; near-infrared spectroscopy;
D O I
10.1016/j.ejcts.2004.12.046
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Although malposition of a catheter for selective cerebral perfusion can lead to postoperative neurologic complications, the clinical relevance or even an incidence of this event is not clear because there have been no measures to diagnose it. The purpose of this study is to report the results of intraoperative diagnosis of catheter malposition by means of near-infrared spectroscopy, orbital ultrasound, and transesophageal echocardiography. Methods: The 35 consecutive patients of aortic arch aneurysm undergoing total arch replacement (13 patients) or transaortic stent graft implantation (22 patients) were examined. The regional oxygen saturation in the frontal lobe was continuously monitored with near-infrared spectroscopy. When cerebral malperfusion was suspected with saturation drop and reduced blood flow in orbital ultrasound, blood flow in the cervical branches and catheter position were examined with transesophageal echocardiography. Results: Catheter malposition was detected in 4 of 35 cases (11.4%). The echo findings included: (1) reduced or absent flow and/or collapsed lumen in the common carotid artery despite an adequate perfusion rate; and (2) the balloon of catheter blocking the inflow to the common carotid artery. There was no unusual changes in parameters of other conventional monitors. After the catheter was withdrawn (three cases) or replaced (one case) based on the above diagnosis, cerebral perfusion was restored, confirmed by these three modalities. An accidental entry of catheter into the right common carotid artery was detected by transesophageal echocardiography in one case, in which there was no abnormal finding of oxygen saturation or orbital blood flow. Conclusions: Catheter malposition on the right side is not a rare event during selective cerebral perfusion. The catheter can migrate into the right subclavian artery or common carotid artery. Pressure monitoring cannot reliably detect an occurrence of catheter migration into the right subclavian artery. Combined use of near-infrared spectroscopy, orbital ultrasound, and transesophageal echocardiography can be useful for detecting this event and making an appropriate decision without delay to prevent irreversible brain damage. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:644 / 648
页数:5
相关论文
共 50 条
  • [21] Optimal temperature for selective cerebral perfusion
    Strauch, JT
    Spielvogel, D
    Lauten, A
    Zhang, N
    Rinke, S
    Weisz, D
    Bodian, CA
    Griepp, RB
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2005, 130 (01): : 74 - 82
  • [22] Selective cerebral perfusion: A review of the evidence
    Spielvogel, David
    Kai, Masashi
    Tang, Gilbert H. L.
    Malekan, Ramin
    Lansman, Steven L.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (03): : S59 - S62
  • [23] A rare malposition of the thoracic venous catheter introduced via the left internal jugular vein
    Ghosh, Supradip
    Dewan, Himanshu
    Bhattacharyya, Sandip
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2008, 12 (04) : 201 - 203
  • [24] Integrated Cerebral Protection using Antegrade Selective Cerebral Perfusion
    Kazui, Teruhisa
    17TH ANNUAL MEETING OF THE ASIAN SOCIETY FOR CARDIOVASCULAR AND THORACIC SURGERY - ASCVTS, 2009, : 37 - 44
  • [25] THE PREVENTION TECHNIQUE FOR PD CATHETER MALPOSITION
    Fukasawa, Mizuya
    Fukasawa, Mizuya
    Takeda, Masayuki
    Kamiyama, Manabu
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2012, 27 : 481 - 482
  • [26] Internal jugular venous catheter malposition
    Arya, Virendra K.
    Bangaari, Ashish
    Rahman, Mujeebur
    Rana, Sandeep Singh
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (03) : 465 - 467
  • [27] Malposition of a haemodialysis catheter in a hepatic vein
    Lindner, Ulrich
    Haas, Christian S.
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 2010, 44 (05): : 364 - 365
  • [28] Malposition of Hemodialysis Catheter Into Arch of Aorta
    Tamang, Sangey D.
    Dubey, Prakash K.
    Bharti, Alok K.
    AIN SHAMS JOURNAL OF ANESTHESIOLOGY, 2024, 16 (01)
  • [29] Catheter malposition in infants: A preventable complication
    Balakrishnan, Ira
    Kaur, Manpreet
    Sawhney, Chhavi
    D'Souza, Nita
    INDIAN JOURNAL OF ANAESTHESIA, 2012, 56 (04) : 427 - U123
  • [30] Malposition of hemodialysis catheter into the hepatic veins
    Yucel, Sibel Kocak
    Gumusel, Ceren
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2019, 35 (02) : 583 - 585