Study of control system for X-ray generator

被引:1
|
作者
Guo, Shuangmao [1 ]
Wu, Jianyi [1 ]
Xiang, Mingzhu [1 ]
Wei, Shanwu [1 ]
机构
[1] MPS China, Res Inst 1, Beijing 100044, Peoples R China
关键词
portable; adjustable; full- digital PID algorithm; LCD; computer;
D O I
10.1016/j.proeng.2010.11.032
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
X-ray generator is mainly used for non-destructive testing, security check areas and so on. In order to accurately adjust cross voltage and through current of the X-ray tube, this paper adopts full-digital PID algorithm to control PWM output waveforms. The tube voltage adjustable range is 40 to 120kV and the tube current range is 0.1 to 1.5mA. We can set up work parameters and get the working status by LCD and Console on the generator. It also can be fully controlled by a computer so as to enhance the safety of the operator, simplify operation and so on. (c) 2010 Published by Elsevier Ltd.
引用
收藏
页码:209 / 212
页数:4
相关论文
共 50 条
  • [21] How linearly polarized is the X-ray beam from the X-ray generator?
    Tanaka, S
    Tsunemi, H
    Hayashida, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (9A): : 5770 - 5773
  • [22] Identification of material by X-ray fluorescence analysis with a pyroelectric X-ray generator
    Ali, M.
    Bonnett, E.
    Karataev, P.
    Kubankin, A.
    Oleinik, O.
    Margaryan, V.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (07):
  • [23] Characteristic X-ray generator utilizing angle dependence of bremsstrahlung X-ray distribution
    Sato, E
    Tanaka, E
    Mori, H
    Kawai, T
    Inoue, T
    Ogawa, A
    Sato, S
    Takayama, K
    Onagawa, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (4A): : 2845 - 2849
  • [24] DIGITAL X-RAY MICROSCOPY WITH A MICROFOCAL X-RAY GENERATOR AND AN MWPC AREA DETECTOR
    BATEMAN, JE
    MOSS, GR
    ROCKETT, P
    WEBB, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 767 - 772
  • [25] FIRST RESULTS FROM A NOVEL MICROFOCUS X-RAY GENERATOR FOR X-RAY CRYSTALLOGRAPHY
    Ciszak, Ewa
    Gubarev, Mikhail
    Joy, Marshall
    Gibson, Walter
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 1999, 55 : 82 - 82
  • [26] X-ray Absorption Spectral Analysis with a 9 V Battery X-ray Generator
    Hideshi Ishii
    Jun Kawai
    Analytical Sciences, 2005, 21 : 783 - 784
  • [27] Identification of Glass and Ceramics by X-ray Fluorescence Analysis with a Pyroelectric X-ray Generator
    Hiroyuki Ida
    Jun Kawai
    Analytical Sciences, 2004, 20 : 1211 - 1215
  • [28] X-ray absorption spectral analysis with a 9 V battery X-ray generator
    Ishii, H
    Kawai, J
    ANALYTICAL SCIENCES, 2005, 21 (07) : 783 - 784
  • [29] Characteristic X-ray generator utilizing angle dependence of bremsstrahlung X-ray distribution
    Sato, Eiichi
    Tanaka, Etsuro
    Mori, Hidezo
    Kawai, Toshiaki
    Inoue, Takashi
    Ogawa, Akira
    Sato, Shigehiro
    Takayama, Kazuyoshi
    Onagawa, Jun
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (4 A): : 2845 - 2849
  • [30] Identification of glass and ceramics by X-ray fluorescence analysis with a pyroelectric X-ray generator
    Ida, H
    Kawai, J
    ANALYTICAL SCIENCES, 2004, 20 (08) : 1211 - 1215