Evaluation of two-dimensional dose distributions for pre-treatment patient-specific IMRT dosimetry

被引:4
|
作者
Radojcic, Deni Smilovic [1 ]
Rajlic, David [1 ]
Casar, Bozidar [2 ]
Kolacio, Manda Svabic [1 ]
Obajdin, Nevena [1 ]
Faj, Dario [3 ,4 ]
Jurkovic, Slaven [1 ,5 ]
机构
[1] Univ Hosp Rijeka, Med Phys Dept, Kresimirova 42, Rijeka, Croatia
[2] Inst Oncol LJubljana, Dept Radiat Phys, Ljubljana, Slovenia
[3] Univ Osijek, Fac Med, Osijek, Croatia
[4] Univ Osijek, Fac Dent Med & Hlth, Osijek, Croatia
[5] Univ Rijeka, Dept Med Phys & Biophys, Fac Med, Rijeka, Croatia
关键词
IMRT; 2D dose verification; gamma method; anthropomorphic phantom; WATER; VERIFICATION; PHOTON; TISSUE; BEAMS; FILM;
D O I
10.2478/raon-2018-0019
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. The accuracy of dose calculation is crucial for success of the radiotherapy treatment. One of the methods that represent the current standard for patient-specific dosimetry is the evaluation of dose distributions measured with an ionization chamber array inside a homogeneous phantom using gamma method. Nevertheless, this method does not replicate the realistic conditions present when a patient is undergoing therapy. Therefore, to more accurately evaluate the treatment planning system (TPS) capabilities, gamma passing rates were examined for beams of different complexity passing through inhomogeneous phantoms. Materials and methods. The research was performed using Siemens Oncor Expression linear accelerator, Siemens Somatom Open CT simulator and Elekta Monaco TPS. A 2D detector array was used to evaluate dose distribution accuracy in homogeneous, semi-anthropomorphic and anthropomorphic phantoms. Validation was based on gamma analysis with 3%/3mm and 2%/2mm criteria, respectively. Results. Passing rates of the complex dose distributions degrade depending on the thickness of non-water equivalent material. They also depend on dose reporting mode used. It is observed that the passing rate decreases with plan complexity. Comparison of the data for all set-ups of semi-anthropomorphic and anthropomorphic phantoms shows that passing rates are higher in the anthropomorphic phantom. Conclusions. Presented results raise a question of possible limits of dose distribution verification in assessment of plan delivery quality. Consequently, good results obtained using standard patient specific dosimetry methodology do not guarantee the accuracy of delivered dose distribution in real clinical cases.
引用
收藏
页码:346 / 352
页数:7
相关论文
共 50 条
  • [31] A systematic approach to statistical analysis in dosimetry and patient-specific IMRT plan verification measurements
    Songbing Qin
    Miao Zhang
    Sung Kim
    Ting Chen
    Leonard H Kim
    Bruce G Haffty
    Ning J Yue
    Radiation Oncology, 8
  • [32] Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT
    Hong, Chae Seon
    Lim, Jongsoo
    Ju, Sang Gyu
    Shin, Eunhyuk
    Han, Youngyih
    Ahn, Yong Chan
    RADIATION ONCOLOGY JOURNAL, 2009, 27 (02): : 91 - 102
  • [33] First clinical experience with pre-treatment and in vivo IMRT verification using EPID dosimetry
    McDermott, LN
    Wendling, M
    Sonke, J
    Stroom, J
    van Asselen, B
    van Herk, M
    Mijnheer, B
    MEDICAL PHYSICS, 2005, 32 (06) : 2090 - 2090
  • [34] Need of patient-specific quality assurance and pre-treatment verification program for special plans in radiotherapy
    Ravichandran, Ramamoorthy
    Bhasi, Saju
    Binukumar, J. P.
    Davis, C. A.
    JOURNAL OF MEDICAL PHYSICS, 2011, 36 (03) : 181 - 183
  • [35] Of the effective dose in the diagnosis of a patient-specific Dosimetry in nuclear medicine Therapy
    Lassmann, M.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2011, 50 (06): : 221 - 223
  • [36] Evaluation of a patient-specific Monte Carlo software for CT dosimetry
    Myronakis, Marios
    Perisinakis, Kostas
    Tzedakis, Antonis
    Gourtsoyianni, Sofia
    Damilakis, John
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (04) : 248 - 255
  • [37] IMRT patient-specific QA using the Delta4 dosimetry system and evaluation based on ICRU 83 recommendations
    Nilsson, J.
    Hauer, A. Karlsson
    Back, A.
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [38] TransQA: deep hybrid transformer network for measurement-guided volumetric dose prediction of pre-treatment patient-specific quality assurance
    Zeng, Lingpeng
    Zhang, Minghui
    Zhang, Yun
    Zou, Zhongsheng
    Guan, Yu
    Huang, Bin
    Yu, Xiuwen
    Ding, Shenggou
    Liu, Qiegen
    Gong, Changfei
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (20):
  • [39] Dosimetry Sensitivity in a Lower Dimensional Model of Patient-Specific Asthma Subjects
    Poorbahrami, Kamran
    Allshouse, Michael R.
    Oakes, Jessica M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2023, 70 (09) : 2581 - 2591
  • [40] Retrospective analysis of portal dosimetry pre-treatment quality assurance of hybrid IMRT breast treatment plans
    Koo, Meghan
    Darko, Johnson
    Osei, Ernest
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2021, 20 (01) : 22 - 29