Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging

被引:4
|
作者
Zhang Xiao-chun [2 ]
Yang Zhi-gang [1 ]
Guo Yin-kun [1 ]
Zhang Rui-ming [3 ]
Wang Jian [2 ]
Zhou Dai-quan [2 ]
Cheng Lin [2 ]
Chen Lin [2 ]
机构
[1] Sichuan Univ, W China Hosp, Dept Radiol, Chengdu 610041, Sichuan, Peoples R China
[2] Third Mil Med Univ, Southwest Hosp, Dept Radiol, Chongqing 400038, Peoples R China
[3] First Affiliated Hosp, Inner Mongolia Med Coll, Dept Gen Surg, Hohhot 410041, Inner Mongolia, Peoples R China
关键词
cardiac imaging techniques; ventricular function; mitral valve stenosis; magnetic resonance imaging; VALVULAR HEART-DISEASE; EJECTION FRACTION; CARDIAC-FUNCTION; CT; ECHOCARDIOGRAPHY; ACCURACY; REPRODUCIBILITY; FAILURE; VOLUMES;
D O I
10.3760/cma.j.issn.0366-6999.2012.08.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Right ventricular (RV) dysfunction ensues due to rheumatic mitral stenosis (RMS). The evaluation of RV function is clinically important for the diagnosis, treatment, and follow-up for patients with different degrees of RMS. The purpose of this study was to determine whether the 64-slice multi-detector row computed tomography (64-slice MDCT) can assess the RV function in RMS with high accuracy and reproducibility when compared to MR imaging (MRI). Methods Right ventricular end-diastolic and end-systolic volumes (RV-EDV and RV-ESV), stroke volume (RV-SV), ejection fraction (RV-EF), cardiac output (RV-CO), and wall mass (RV-Mass) were measured with dedicated cardiac analysis software on 64-slice MDCT and compared with values measured with MRI in 43 consecutive patients with RMS. Agreement between MRI and 64-MDCT results were compared with Bland and Altman analysis and linear regression analysis. Repeated measurements were performed to determine intraobserver and interobserver variability. Results No significant differences were revealed in calculated RV function parameters between the two methods. RV-EDV, RV-ESV, RV-SV, RV-EF, RV-CO, and RV-Mass by 64-slice MDCT were similar to those by MRI (P>0.05). There were good correlations (r=0.98, 0.97, 0.96, 0.96, 0.95 and 0.77, respectively) and close agreement (bias=-0.2 ml, -1.0 ml, 0.8 ml, 0.5%, 26.1 ml, and 0.5 g, respectively, P>0.05). The variability in 64-slice MDCT measurements was similar to that in MRI values. Conclusion ECG-gated 64-slice MDCT could assess the RV function in RMS with high accuracy and reproducibility when compared to MRI. Chin Med J 2012;125(8):1469-1474
引用
收藏
页码:1469 / 1474
页数:6
相关论文
共 50 条
  • [21] A Case Study on Cardiac Imaging in Patients with Arrhythmogenic Right Ventricular Dysplasia/Cardiomyopathy - A Comparison between 64-Slice Computed Tomography, Magnetic Resonance Imaging and Electroanatomical Mapping
    Nishiyama, Kei
    Doi, Takahiro
    Shizuta, Satoshi
    Yamamoto, Takayuki
    Hanazawa, Kouji
    Kita, Toru
    Kimura, Takeshi
    JOURNAL OF ARRHYTHMIA, 2007, 23 (04) : 277 - 284
  • [22] The role of 64-slice multi-detector computed tomography in the detection of subclinical atherosclerosis of the coronary artery
    Hae Chang Jeong
    Youngkeun Ahn
    Jum Suk Ko
    Min Goo Lee
    Doo Sun Sim
    Keun Ho Park
    Nam Sik Yoon
    Hyun Ju Youn
    Young Joon Hong
    Kye Hun Kim
    Hyung Wook Park
    Ju Han Kim
    Yun-Hyeon Kim
    Myung Ho Jeong
    Jeong Gwan Cho
    Jong Chun Park
    Jung Chaee Kang
    The International Journal of Cardiovascular Imaging, 2010, 26 : 253 - 259
  • [23] The role of 64-slice multi-detector computed tomography in the detection of subclinical atherosclerosis of the coronary artery
    Jeong, Hae Chang
    Ahn, Youngkeun
    Ko, Jum Suk
    Lee, Min Goo
    Sim, Doo Sun
    Park, Keun Ho
    Yoon, Nam Sik
    Youn, Hyun Ju
    Hong, Young Joon
    Kim, Kye Hun
    Park, Hyung Wook
    Kim, Ju Han
    Kim, Yun-Hyeon
    Jeong, Myung Ho
    Cho, Jeong Gwan
    Park, Jong Chun
    Kang, Jung Chaee
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 : 253 - 259
  • [24] Assessment of the morphological features of degenerative mitral valve disease using 64-slice multi detector computed tomography
    Smith, Thomas
    Gurudevan, Swaminatha
    Cheng, Victor
    Trento, Alfredo
    DeRobertis, Mick
    Thomson, Louise
    Friedman, John
    Hayes, Sean
    Siegel, Robert J.
    Berman, Daniel S.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) : 415 - 421
  • [25] Usefulness of 64-slice multi-detector computed tomography as a first diagnostic approach in acute chest pain patients
    Chang, Sung-A
    Choi, Eue-Keun
    Kim, Hyung-Kwan
    Jung, Jin-Wook
    Kim, Kyu-Seok
    Chun, Eun-Ju
    Choi, Sang-il
    Cho, Young-Seok
    Chung, Woo-Young
    Chae, In-Ho
    Choi, Dong-Joo
    Oh, Byung-Hee
    Park, Young-Bae
    Choi, Yun-Shik
    Chang, Hyuk-Jae
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 106A - 106A
  • [26] Left ventricular functional analysis using 64-slice multidetector row computed tomography: Comparison with left ventriculography and cardiovascular magnetic resonance
    Wu, Yen-Wen
    Tadamura, Eiji
    Kanao, Shotaro
    Yamamuro, Masaki
    Okayama, Satoshi
    Ozasa, Neiko
    Toma, Masanao
    Kimura, Takeshi
    Kita, Toru
    Marui, Akira
    Komeda, Masashi
    Togashi, Kaori
    CARDIOLOGY, 2008, 109 (02) : 135 - 142
  • [27] Papillary fibroelastoma of the mitral valve: appearance in 64-slice spiral computed tomography, magnetic resonance imaging, and echocardiography
    Kondruweit, Markus
    Schmid, Michael
    Strecker, Thomas
    EUROPEAN HEART JOURNAL, 2008, 29 (06) : 831 - 831
  • [28] Analysis of cardiac dimensions, mass and function in heart transplant recipients using 64-slice multi-detector computed tomography
    Ferencik, Maros
    Gregory, Shawn A.
    Butler, Javed
    Achenbach, Stephan
    Yeh, Robert W.
    Hoffmann, Udo
    Inglessis, Ignacio
    Cury, Ricardo C.
    Nieman, Koen
    McNulty, Iris A.
    Healy, Josephine A.
    Brady, Thomas J.
    Semigran, Marc J.
    Jang, Ik-Kyung
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2007, 26 (05): : 478 - 484
  • [29] Quantification of Left Ventricular Parameters Obtained by Automated Software for 64-Slice Multidetector Computed Tomography and Comparison with Magnetic Resonance Imaging
    Akram, Kamran
    Anderson, Hunt D.
    Voros, Szilard
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (06) : 1154 - 1160
  • [30] Quantification of Left Ventricular Parameters Obtained by Automated Software for 64-Slice Multidetector Computed Tomography and Comparison with Magnetic Resonance Imaging
    Kamran Akram
    Hunt D. Anderson
    Szilard Voros
    CardioVascular and Interventional Radiology, 2009, 32 : 1154 - 1160