摘要
Purpose To compare EPI and GRE readout in high-flow velocity regimes and evaluate their impact on measurement accuracy in silico and in vitro. Theory and Methods Phase-contrast sequences for EPI and GRE were simulated using CFD velocity data to assess displacement artifacts as well as effective spatial resolution. In silico findings were validated experimentally using a steady flow phantom. Results For EPI factor 5 and simulated stenotic flow with peak velocity of 2.2 ms-1, displacement artifacts resulted in misregistration of 7.3 mm at echo time and the effective resolution was locally reduced by factors 5 and 8 compared to GRE for flow along phase and frequency encoding directions, respectively. In vitro, a maximum velocity difference between EPI factor 5 and GRE of 0.97 ms-1 was found. Conclusions Four-dimensional flow MRI using EPI readout results not only in considerable velocity misregistration but also in spatially varying degradation of resolution. The proposed work indicates that EPI is inferior to standard GRE for 4D flow MRI.
引用
收藏
页码:1806 / 1816
页数:11
相关论文
共 50 条
  • [31] Turning Up the Flow: Cardiovascular 4D Flow MRI during Exercise
    Markl, Michael
    Lee, Jeesoo
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2020, 2 (03):
  • [32] Aortocaval Fistula at 4D Flow MRI: Visualization and Quantification of Vascular Flow
    Lebenatus, Annett
    Ravesh, Mona Salehi
    RADIOLOGY, 2018, 289 (03) : 617 - 617
  • [33] Optimizing encoding strategies for 4D Flow MRI of mean and turbulent flow
    Dirix, Pietro
    Buoso, Stefano
    Kozerke, Sebastian
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [34] A physiologic flow phantom for the evaluation of 4D flow MRI in the left ventricle
    Ikechukwu (Ikay) Okafor
    Christine Garcia
    Alex J Barker
    John Oshinski
    Ajit P Yoganathan
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [35] 4D magnetic resonance flow imaging (4D flow MRI) in neonates Normal values, changes over time and feasibility
    Vejlstrup, A. M.
    Kromann, J.
    Bundgaard, H.
    Iversen, K.
    Vejlstrup, N.
    EUROPEAN HEART JOURNAL, 2018, 39 : 162 - 162
  • [36] Data Quality and Optimal Background Correction Order of Respiratory-Gated k-Space Segmented Spoiled Gradient Echo (SGRE) and Echo Planar Imaging (EPI)-Based 4D Flow MRI
    Viola, Federica
    Dyverfeldt, Petter
    Carlhall, Carl-Johan
    Ebbers, Tino
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (03) : 885 - 896
  • [37] Sketch-based Registration of 3D Cine MRI to 4D flow MRI
    Sabokrohiyeh, Samin
    Ang, Kathleen
    Elbaz, Mohammed
    Samavati, Faramarz
    ICBBT 2019: 2019 11TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL TECHNOLOGY, 2019, : 14 - 21
  • [38] Improved respiratory navigator gating for thoracic 4D flow MRI
    van Ooij, Pim
    Semaan, Edouard
    Schnell, Susanne
    Giri, Shivraman
    Stankovic, Zoran
    Carr, James
    Barker, Alex J.
    Markl, Michael
    MAGNETIC RESONANCE IMAGING, 2015, 33 (08) : 992 - 999
  • [39] Clinical Applications of 4D Flow MRI in the Portal Venous System
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Reeder, Scott B.
    Roldan-Alzate, Alejandro
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 340 - 353
  • [40] An analysis of reconstruction noise from undersampled 4D flow MRI
    Partin, Lauren
    Schiavazzi, Daniele E.
    Long, Carlos A. Sing
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 84