Aptamer Biosensors for Label-Free Colorimetric Detection of Human IgE Based on Polydiacetylene (PDA) Supramolecules

被引:10
|
作者
Kim, Jun Pyo [2 ]
Park, Cheol Hee [2 ]
Sim, Sang Jun [1 ]
机构
[1] Korea Univ, Dept Chem & Biol Engn, Seoul 136713, South Korea
[2] Sungkyunkwan Univ, Dept Chem Engn, Suwon 440746, South Korea
关键词
Polydiacetylene; Biosensor; Aptamer; IgE; IN-VITRO SELECTION; VESICLES; CHROMISM; COLOR; BIND;
D O I
10.1166/jnn.2011.3664
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, we demonstrate an aptamer-based biosensor (apta-biosensor) using PDA liposomes for label-free detection of allergy diagnosis by hIgE detection. In order to detect the target hIgE, the surface of PDA liposome were functionalized with hIgE antibody and anti-hIgE aptamer as a receptor, and the target hIgE onto the receptors was detected by the change of fluorescence signal. The hIgE antibody-modified PDA liposome biosensor had a serious problem that the immune reaction between receptor and target could not powerfully affect the change of florescence signal on PDA liposorne. In order to solve this problem, the anti-hIgE aptamer which was far smaller than whole antibody was introduced as the receptor for the PDA liposome system. An aptamer-based PDA liposome biosensor was able to measure a quantity of target protein with various concentrations and at this time the detection limit was 141 ng/mL of the hIgE concentration. These results enabled diagnosis of allergy disease by an aptamer-based PDA liposome biosensor because real allergic patients showed high concentration of hIgE in serum (greater than 290 ng/mL). Therefore, we suggest that aptamer-modified PDA supramolecules as promising candidates for development of label-free colorimetric biosensors.
引用
收藏
页码:4269 / 4274
页数:6
相关论文
共 50 条
  • [31] Aptamer and DNAzyme Based Colorimetric Biosensors for Pathogen Detection
    Liu, Rudi
    Li, Jiuxing
    Salena, Bruno J.
    Li, Yingfu
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2025, 64 (08)
  • [32] Label-free aptamer-based colorimetric detection of mercury ions in aqueous media using unmodified gold nanoparticles as colorimetric probe
    Li Li
    Baoxin Li
    Yingying Qi
    Yan Jin
    Analytical and Bioanalytical Chemistry, 2009, 393 : 2051 - 2057
  • [33] Label-free aptamer-based colorimetric detection of mercury ions in aqueous media using unmodified gold nanoparticles as colorimetric probe
    Li, Li
    Li, Baoxin
    Qi, Yingying
    Jin, Yan
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (08) : 2051 - 2057
  • [34] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [35] Electrochemical aptamer biosensor for DNA detection based on label-free aptamers
    Li, Li
    Chen, Zhengbo
    BIOELECTROCHEMISTRY, 2023, 153
  • [36] A Label-Free Electrochemical Aptasensor Based on a Truncated Aptamer for the Detection of Progesterone
    Yang, Jie
    Hou, Yucui
    Ren, Yi
    Tang, Chunhua
    Li, HuanHuan
    Huang, Jing
    Jiang, Hanbing
    Cai, Tongji
    Zhao, Jia
    Yu, Peng
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2022, 18 (11) : 2498 - 2507
  • [37] Colorimetric two-dimensional photonic crystal biosensors for label-free detection of hydrogen peroxide
    Liu, Ruixiang
    Cai, Zhongyu
    Zhang, Qingsong
    Yuan, Heng
    Zhang, Guanglei
    Yang, De'an
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 354
  • [38] Nanocrystalline diamond impedimetric aptasensor for the label-free detection of human IgE
    Tran, Dinh T.
    Vermeeren, Veronique
    Grieten, Lars
    Wenmackers, Sylvia
    Wagner, Patrick
    Pollet, Jeroen
    Janssen, Kris P. P.
    Michiels, Luc
    Lammertyn, Jeroen
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (06): : 2987 - 2993
  • [39] A Label-Free Aptamer-Based Fluorescent Assay for Cadmium Detection
    Luan, Yunxia
    Lu, Anxiang
    Chen, Jiayi
    Fu, Hailong
    Xu, Li
    APPLIED SCIENCES-BASEL, 2016, 6 (12):
  • [40] Label-free electrochemical detection for aptamer-based array electrodes
    Xu, DK
    Xu, DW
    Yu, XB
    Liu, ZH
    He, W
    Ma, ZQ
    ANALYTICAL CHEMISTRY, 2005, 77 (16) : 5107 - 5113