Polarised neutron reflectometry for GMR sensors optimization

被引:6
|
作者
Pannetier, M [1 ]
Doan, TD
Ott, F
Berger, S
Persat, N
Fermon, C
机构
[1] Ctr Etud Saclay, CEA, CNRS, Lab Leon Brillouin, F-91191 Gif Sur Yvette, France
[2] CEA Saclay, DSM DRECAM SPEC, F-91191 Gif Sur Yvette, France
[3] OnStream MST BV, NL-5652 AC Eindhoven, Netherlands
来源
EUROPHYSICS LETTERS | 2003年 / 64卷 / 04期
关键词
D O I
10.1209/epl/i2003-00262-4
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Neutron reflectometry with spin analysis has allowed us to perform selective hysteresis loops of each magnetic layer in GMR spin valves. The intensities now available on reflectometers and the advances of modelling give the possibility to perform a very precise analysis of the magnetic configuration even in complex systems with five different magnetic layers. Results obtained on GMR spin valves show a rather complex behaviour of the free layer as a function of the magnetic field. The NiFe soft layer exhibits a non-homogeneous rotation which cannot be observed in transport measurements. This non-homogeneous rotation explains the necessity of a rather thick soft layer to avoid 1/f magnetic noise in GMR sensors.
引用
收藏
页码:524 / 528
页数:5
相关论文
共 50 条
  • [31] Adapting GMR sensors for integrated devices
    Ludwig, K
    Hauch, J
    Mattheis, R
    Barholz, KU
    Rieger, G
    SENSORS AND ACTUATORS A-PHYSICAL, 2003, 106 (1-3) : 15 - 18
  • [32] FET Protection of GMR and TMR Sensors
    Iben, Icko Eric Timothy
    Loiseau, Alain
    Gebreselasie, Ephrem
    2014 36TH ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM (EOS/ESD), 2014,
  • [33] Vibration Detector Based on GMR Sensors
    Sebastia, Jose Pelegri
    Lluch, Jorge Alberola
    Vizcaino, J. Rafael Lajara
    Bellon, Jesus Santiso
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2009, 58 (03) : 707 - 712
  • [34] GMR sensors for contactless position detection
    Rieger, G
    Ludwig, K
    Hauch, J
    Clemens, W
    SENSORS AND ACTUATORS A-PHYSICAL, 2001, 91 (1-2) : 7 - 11
  • [35] ESD Events of Cabled GMR Sensors
    Iben, Icko Eric Timothy
    ELECTRICAL OVERSTRESS/ELECTROSTATIC DISCHARGE SYMPOSIUM PROCEEDINGS 2010, 2010,
  • [36] On the Optimization of Neutron-Reflectometry Experiments on Thin Films of Hybrid Perovskites for Photovoltaics
    Avdeev, M. V.
    Tropin, T. V.
    Sadilov, V. V.
    JOURNAL OF SURFACE INVESTIGATION, 2024, 18 (05): : 1255 - 1259
  • [37] Resonant Neutron Reflectometry on a Compact Neutron Source
    Nikova, E. S.
    Salamatov, Yu. A.
    Kravtsov, E. A.
    JOURNAL OF SURFACE INVESTIGATION, 2023, 17 (04): : 826 - 831
  • [38] Polarised neutron scattering from dynamic polarised nuclei 1972–2022
    Heinrich B. Stuhrmann
    The European Physical Journal E, 2023, 46
  • [39] Resonant Neutron Reflectometry on a Compact Neutron Source
    E. S. Nikova
    Yu. A. Salamatov
    E. A. Kravtsov
    Journal of Surface Investigation: X-ray, Synchrotron and Neutron Techniques, 2023, 17 : 826 - 831
  • [40] The study of perpendicular magnetic anisotropy in the magnetic sensors with linear sensitivity using polarized neutron reflectometry
    Zhu, T.
    INTERNATIONAL CONFERENCE ON POLARISED NEUTRONS FOR CONDENSED MATTER INVESTIGATIONS (PNCMI 2014), 2016, 711