HIGH-RESOLUTION GLYPH-INSPECTION BASED SECURITY SYSTEM

被引:7
|
作者
Simske, Steven J. [1 ]
Adams, Guy [2 ]
机构
[1] Hewlett Packard Labs, 3404 E Harmony Rd,MS 36, Ft Collins, CO 80528 USA
[2] Hewlett Packard Labs, Bristol, Avon BS34 8QZ, England
关键词
Image forensics; CMOS imaging; authentication; print parasitics; security; counterfeit detection;
D O I
10.1109/ICASSP.2010.5495416
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This paper describes the use of a 1:1 magnification 3.5 micron true resolution Dyson Relay lens-based 3 MPixel USB CMOS imaging device (DR CID) and software forensic image analysis system. The device enables the simultaneous capture of both intentional printing shapes and unintentional printing artifacts caused by the printing process and the interaction of the ink with the substrate on which printing occurs. The custom image analysis system written for the DR CID device allows even a single printed character to simultaneously provide fiducial marking, inspection information, authentication and forensics. We report herein on the sensitivity of the system and initial results for the reliable authentication of a printed character using DR CID hardware devices.
引用
收藏
页码:1794 / 1797
页数:4
相关论文
共 50 条
  • [31] High-resolution wafer inspection using the ''in-lens SEM''
    Mizuno, F
    Yamada, S
    Ohtaka, T
    Tsumaki, N
    Koike, T
    IEICE TRANSACTIONS ON ELECTRONICS, 1996, E79C (03) : 317 - 323
  • [32] Design of High-Resolution FPD System Based on Doglegged Sampling
    Zhang, Baolong
    Wang, Jingyun
    ELECTRONICS, MECHATRONICS AND AUTOMATION III, 2014, 666 : 93 - 97
  • [33] Demagnifying high-resolution imaging based on a new system for nanolithography
    Meng, Qingqing
    Zhang, Xiaoping
    Cheng, Lin
    Cao, Pengfei
    Li, Yuee
    Jin, Xin
    OPTICS COMMUNICATIONS, 2011, 284 (16-17) : 3891 - 3894
  • [34] Characterization of a sCMOS-based high-resolution imaging system
    Mittone, Alberto
    Manakov, Ilja
    Broche, Ludovic
    Jarnias, Christophe
    Coan, Paola
    Bravin, Alberto
    JOURNAL OF SYNCHROTRON RADIATION, 2017, 24 : 1226 - 1236
  • [35] Coincidence-based High-resolution Analysis for On-site-inspection Spectrometry (CHAOS) development
    Britton, R.
    Davies, A., V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 940 : 215 - 222
  • [36] HIGH-RESOLUTION TOWED OSCILLATING SYSTEM
    DESTROBEL, F
    GUALDESI, L
    SEA TECHNOLOGY, 1994, 35 (07) : 37 - 40
  • [37] HIGH-RESOLUTION GUIDED RADAR SYSTEM
    MACKAY, NA
    BEATTIE, DG
    ELECTRONICS LETTERS, 1976, 12 (22) : 583 - 584
  • [38] A NEW HIGH-RESOLUTION SYSTEM OF AUTORADIOGRAPHY
    GOMBERG, HJ
    NUCLEONICS, 1951, 9 (04): : 28 - 43
  • [39] A NEW HIGH-RESOLUTION REDUCTION SYSTEM
    DELANO, E
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1960, 50 (11) : 1125 - 1125
  • [40] HIGH-RESOLUTION ULTRASONIC SCANNING SYSTEM
    HURWITZ, MJ
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (01): : 308 - &