Quantitative coherent scatter computed tomography

被引:7
|
作者
Batchelar, DL [1 ]
Westmore, MS [1 ]
Lai, H [1 ]
Cunningham, IA [1 ]
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
来源
PHYSICS OF MEDICAL IMAGING | 1998年 / 3336卷
关键词
X-ray diffraction; computed tomography; material-specific imaging; bone-mineral content (BMC);
D O I
10.1117/12.317076
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional means of diagnosing and assessing the progression of osteoporosis, including radiographic absorptiometry and quantitative CT, are directly or indirectly dependent upon bone density. This is, however, not always a reliable indicator of fracture risk. Changes in the trabecular structure and bone mineral content (BMC) are thought to provide a better indication of the chance of spontaneous fractures occurring. Coherent-scatter CT (CSCT) is a technique which produces images based on the low angle (0-10 degrees) x-ray diffraction properties of tissue. Diffraction patterns from an object are acquired using first-generation CT geometry with a diagnostic x-ray image intensifier based system. These patterns are used to reconstruct a series of maps of the angle dependent coherent scatter cross section in a tomographic slice which are dependent upon the molecular structure of the scatterer. Hydroxyapatite has a very different cross section to that of soft tissue, and the CSCT method may, therefore, form the basis for a more direct measure of BMC. Our original CSCT images suffered from a "cupping" artifact, resulting in increased intensities for pixels at the periphery of the object. This artifact, which is due to self-attenuation of scattered x rays, caused a systematic error of up to 20% in cross-sections measured from a CT image. This effect has been removed by monitoring the transmitted intensity using a photodiode mounted on the primary beam stop, and normalizing the scatter intensity to that of the transmitted beam for each projection. Images reconstructed from data normalized in this way do not exhibit observable attenuation artifacts. Elimination of this artifact enables the determination of accurate quantitative measures of BMC at each pixel in a tomograph.
引用
收藏
页码:707 / 715
页数:9
相关论文
共 50 条
  • [31] X-ray scatter in quantitative megavoltage computed tomography: Implications for adaptive radiation therapy
    Hajdok, G
    Battista, JJ
    Cunningham, IA
    Kron, T
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 508 - 517
  • [32] Coherent scatter tomography using a sliding detector system
    Terabe, Mitsuaki
    Inoue, Kenzou
    Okamoto, Hiroyuki
    Koshida, Kichirou
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [33] Non-invasive classification of breast microcalcifications using x-ray coherent scatter computed tomography
    Ghammraoui, Bahaa
    Popescu, Lucretiu M.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (03): : 1192 - 1207
  • [34] Pseudomonoenergetic x-ray diffraction measurements using balanced filters for coherent-scatter computed tomography
    Beath, S. R.
    Cunningham, I. A.
    MEDICAL PHYSICS, 2009, 36 (05) : 1839 - 1847
  • [35] NON DESTRUCTIVE EX VIVO URINARY STONE COMPOSITION ANALYSIS USING COHERENT-SCATTER COMPUTED TOMOGRAPHY
    Probst, C. Mendez
    Nott, L.
    Denstedt, J.
    Cunningham, I.
    JOURNAL OF ENDOUROLOGY, 2009, 23 : A102 - A103
  • [36] X-Ray Computed Tomography Through Scatter
    Geva, Adam
    Schechner, Yoav Y.
    Chernyak, Yonatan
    Gupta, Rajiv
    COMPUTER VISION - ECCV 2018, PT XIV, 2018, 11218 : 37 - 54
  • [37] Demonstration of Dose and Scatter Reductions for Interior Computed Tomography
    Bharkhada, Deepak
    Yu, Hengyong
    Dixon, Robert
    Wei, Yuchuan
    Carr, J. Jeffrey
    Bourland, J. Daniel
    Best, Ryan
    Hogan, Richard
    Wang, Ge
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2009, 33 (06) : 967 - 972
  • [38] CORRECTION OF SCATTER IN COMPUTED-TOMOGRAPHY IMAGES OF BONE
    HANGARTNER, TN
    MEDICAL PHYSICS, 1987, 14 (03) : 335 - 340
  • [39] A Scatter-Rejection Method for Proton Computed Tomography
    Houri, J.
    Kapadia, A.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [40] Update on Quantitative Computed Tomography
    Cheng, Xiaoguang
    Wang, Ling
    Blake, Glen M.
    Guglielmi, Giuseppe
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2024, 28 (05) : 557 - 559