Quantitative coherent scatter computed tomography

被引:7
|
作者
Batchelar, DL [1 ]
Westmore, MS [1 ]
Lai, H [1 ]
Cunningham, IA [1 ]
机构
[1] John P Robarts Res Inst, Imaging Res Labs, London, ON N6A 5K8, Canada
来源
PHYSICS OF MEDICAL IMAGING | 1998年 / 3336卷
关键词
X-ray diffraction; computed tomography; material-specific imaging; bone-mineral content (BMC);
D O I
10.1117/12.317076
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional means of diagnosing and assessing the progression of osteoporosis, including radiographic absorptiometry and quantitative CT, are directly or indirectly dependent upon bone density. This is, however, not always a reliable indicator of fracture risk. Changes in the trabecular structure and bone mineral content (BMC) are thought to provide a better indication of the chance of spontaneous fractures occurring. Coherent-scatter CT (CSCT) is a technique which produces images based on the low angle (0-10 degrees) x-ray diffraction properties of tissue. Diffraction patterns from an object are acquired using first-generation CT geometry with a diagnostic x-ray image intensifier based system. These patterns are used to reconstruct a series of maps of the angle dependent coherent scatter cross section in a tomographic slice which are dependent upon the molecular structure of the scatterer. Hydroxyapatite has a very different cross section to that of soft tissue, and the CSCT method may, therefore, form the basis for a more direct measure of BMC. Our original CSCT images suffered from a "cupping" artifact, resulting in increased intensities for pixels at the periphery of the object. This artifact, which is due to self-attenuation of scattered x rays, caused a systematic error of up to 20% in cross-sections measured from a CT image. This effect has been removed by monitoring the transmitted intensity using a photodiode mounted on the primary beam stop, and normalizing the scatter intensity to that of the transmitted beam for each projection. Images reconstructed from data normalized in this way do not exhibit observable attenuation artifacts. Elimination of this artifact enables the determination of accurate quantitative measures of BMC at each pixel in a tomograph.
引用
收藏
页码:707 / 715
页数:9
相关论文
共 50 条
  • [1] Energy-dispersive coherent scatter computed tomography
    Delfs, J.
    Schlomka, J. -P.
    [J]. APPLIED PHYSICS LETTERS, 2006, 88 (24)
  • [2] A coherent scatter computed tomography with scintillator-CCD system
    Hoshino, A
    Takeda, T
    Akiba, M
    Kazama, M
    Watanabe, Y
    Yuasa, T
    Hyodo, K
    Uchida, A
    Akatsuka, T
    Itai, T
    [J]. PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 726 - 727
  • [3] Monte Carlo Simulation of Coherent Scatter Computed Tomography (CSCT)
    Lewis, K.
    Donnelly, E.
    Pickens, D.
    Price, R.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [4] Coherent scatter computed tomography - A novel medical imaging technique
    Schlomka, JP
    Harding, A
    van Stevendaal, U
    Grass, M
    Harding, G
    [J]. MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 256 - 265
  • [5] Coherent Scatter Computed Tomography applying a fan-beam geometry
    Schneider, SM
    Schlomka, JP
    Harding, G
    [J]. MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 754 - 763
  • [6] Coherent scatter X-ray computed tomography in medical applications
    Schlomka, JP
    Harding, A
    Harding, G
    van Stevendaal, U
    Grass, A
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 900 - 901
  • [7] A new reconstruction algorithm for energy-resolved coherent scatter computed tomography
    van Stevendaal, U
    Schlomka, JP
    Thran, A
    Delfs, J
    Barschdorf, H
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 2083 - 2093
  • [8] Quantitative assessment of a beam hole scatter correction in industrial computed tomography
    Kaufmann, Manuel
    Pfaffelhuber, Carla
    Vater, Ingo
    Wiest, Wolfram
    Hoehe, Hendrik
    Effenberger, Ira
    [J]. TM-TECHNISCHES MESSEN, 2022, 89 (09) : 625 - 633
  • [9] A reconstruction algorithm for coherent scatter computed tomography based on filtered back-projection
    van Stevendaal, U
    Schlomka, JP
    Harding, A
    Grass, M
    [J]. MEDICAL PHYSICS, 2003, 30 (09) : 2465 - 2474
  • [10] Novel concept for coherent scatter X-ray computed tomography in medical applications
    Schlomka, JP
    Schneider, SM
    Harding, G
    [J]. PENETRATING RADIATION SYSTEMS AND APPLICATIONS II, 2000, 4142 : 218 - 224