Accuracy of the biceps tendon sheath injection: ultrasound-guided or unguided injection? A randomized controlled trial

被引:70
|
作者
Hashiuchi, Tomohisa [1 ]
Sakurai, Goro [1 ]
Morimoto, Mitsutoshi [1 ]
Komei, Tatsuya [1 ]
Takakura, Yoshinori [1 ]
Tanaka, Yasuhito [2 ]
机构
[1] Nishinara Cent Hosp, Dept Orthopaed Surg, Nara 6310024, Japan
[2] Nara Med Univ, Dept Orthopaed Surg, Kashihara, Nara 634, Japan
关键词
Biceps tendon sheath; accuracy; injection; ultrasound; ROTATOR CUFF TEARS; MUSCULOSKELETAL INFECTIONS; ARTHROSCOPIC FINDINGS; LONG HEAD; SHOULDER; ULTRASONOGRAPHY; DIAGNOSIS;
D O I
10.1016/j.jse.2011.04.004
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Patients often localize pain in the anterior shoulder; however, this patient-localized pain does not necessarily correlate to the location of disease. Unguided shoulder injections are common in clinical practice. The accuracy of unguided biceps tendon sheath injections has not been studied. Patient management may be aided by the knowledge of injection accuracy. This study compared the accuracy of ultrasound-guided biceps tendon sheath injection with unguided injection. Materials and methods: The study comprised 30 patients (30 shoulders) with reported anterior shoulder pain who had a primary diagnosis of tenosynovitis or tendinitis of the biceps tendon, or both. Shoulders were randomly allocated into ultrasound-guided and unguided injection groups. Computed tomography (CT) imaging was performed immediately after a contrast agent was injected into the biceps tendon sheath. The locations of contrast seen on CT scan were classified into 3 types: only within the tendon sheath (type 1); inside the tendon, tendon sheath, and surrounding area (type 2); and only the area outside the tendon sheath (type 3). Results: Ultrasound-guided injections resulted in 86.7% type 1 and 13.3% type 2 locations. Unguided injections resulted in 26.7% type 1, 40.0% type 2, and 33.3% type 3 locations. The difference for each location type was significant (P < .05). Conclusion: Injection into the tendon sheath of the long head of the biceps brachii can be more accurately performed using ultrasound guidance than by the blind method. Level of evidence: Level II, Randomized Controlled Trial, Treatment Study. (C) 2011 Journal of Shoulder and Elbow Surgery Board of Trustees.
引用
收藏
页码:1069 / 1073
页数:5
相关论文
共 50 条
  • [41] Ultrasound-Guided Examination and Injection of the Shoulder
    Chiang, Yi-Pin
    Feng, Chien-Fei
    Lew, Henry L.
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2011, 90 (07) : 616 - 617
  • [42] Ultrasound-guided injection of ganglia with coricosteroids
    Breidahl, WH
    Adler, RS
    SKELETAL RADIOLOGY, 1996, 25 (07) : 635 - 638
  • [43] Ultrasound-guided sacroiliac joint injection
    Mezian, K.
    Sobotova, K.
    Novotny, T.
    Vacek, J.
    Kozak, S.
    Nanka, O.
    CESKA A SLOVENSKA NEUROLOGIE A NEUROCHIRURGIE, 2021, 84 (05) : 481 - 485
  • [44] Ultrasound-guided injection of ectopic pregnancy
    Natofsky, JG
    Lense, J
    Mayer, JC
    Yeko, TR
    CLINICAL OBSTETRICS AND GYNECOLOGY, 1999, 42 (01): : 39 - 47
  • [45] Accuracy of Ultrasound-Guided versus Unguided Pes Anserinus Bursa Injections
    Finnoff, Jonathan T.
    Nutz, David J.
    Henning, Philip T.
    Hollman, John H.
    Smith, Jay
    PM&R, 2010, 2 (08) : 732 - 739
  • [46] Corticosteroid injection for trigger finger: blinded or ultrasound-guided injection?
    G. S. Cecen
    D. Gulabi
    F. Saglam
    N. U. Tanju
    H. I. Bekler
    Archives of Orthopaedic and Trauma Surgery, 2015, 135 : 125 - 131
  • [47] Corticosteroid injection for trigger finger: blinded or ultrasound-guided injection?
    Cecen, G. S.
    Gulabi, D.
    Saglam, F.
    Tanju, N. U.
    Bekler, H. I.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2015, 135 (01) : 125 - 131
  • [48] Comparison of the Effect of Ultrasound-Guided Injection of Botulinum Toxin Type A and Corticosteroid in the Treatment of Chronic Plantar Fasciitis A Randomized Controlled Trial
    Ahadi, Tannaz
    Nik, Sasan Sadeghi
    Forogh, Bijan
    Madani, Seyed Pezhman
    Raissi, Gholam Reza
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2022, 101 (08) : 733 - 737
  • [49] ULTRASOUND-GUIDED INJECTION OF LOW MOLECULAR WEIGHT HYALURONIC ACID VERSUS STEROID FOR INFLAMMATORY AND DEGENERATIVE SACROILIITIS: A RANDOMIZED CONTROLLED TRIAL
    Hosny, K.
    Abdelkareem, M. I.
    Moshrif, A.
    ANNALS OF THE RHEUMATIC DISEASES, 2022, 81 : 1727 - 1727
  • [50] Ultrasound-guided Shoulder Intraarticular Ozone Injection Versus Pulsed Radiofrequency Application for Shoulder Adhesive Capsulitis: A Randomized Controlled Trial
    Foula, Ahmed S.
    Sabry, Laila S.
    Elmulla, Ahmed F.
    Kamel, Maher A.
    Hozien, Adel Ibrahim
    PAIN PHYSICIAN, 2023, 26 (03) : E329 - E340