Pentane measurement in ventilated infants using a commercially available system

被引:22
|
作者
Drury, JA
Nycyk, JA
Cooke, RWI
机构
[1] Institute of Child Health, Mersey Regional Neonatal Unit, Liverpool Women's Hospital, Liverpool L8 7SS, Crown Street
关键词
breath pentane; lipid peroxidation; preterm neonate;
D O I
10.1016/S0891-5849(96)00480-7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of breath pentane as a marker of lipid peroxidation has recently been criticized. Problems encountered include the coelution of isoprene with pentane, contamination with exogenous pentane, and the influence of elevated oxygen concentration. The aim of this project was to investigate and evaluate the Chrompack 9001 Gas Chromatograph, using thermal desorption and cryofocussing and an Al2O3/KCl PLOT column with FID, for use in the measurement of breath pentane in ventilated preterm infants. We have clearly separated isoprene from n-pentane and used hydrocarbon free air to clear the airways and avoid contamination with exogenous pentane. Samples should be stored in Tedlar bags for a maximum of 48 h and on capped desorption tubes for no longer than 24 h. Patient variability was relatively high (mean 18%, n = 4); thus, all patients were sampled in duplicate. No correlation was found between fractional inspired oxygen concentration (FiO(2)) and exhaled pentane in preterm infants ventilated far respiratory distress syndrome. In conclusion, we feel that despite the pitfalls and technical difficulties, with careful attention to detail it is possible to reliably measure breath pentane in ventilated preterm infants as an index of lipid peroxidation. Copyright (C) 1997 Elsevier Science Inc.
引用
收藏
页码:895 / 900
页数:6
相关论文
共 50 条
  • [21] A computerized radioactive material inventory system using a commercially available database program
    Hamrick, PE
    HEALTH PHYSICS, 1997, 72 (05): : 788 - 794
  • [22] Implementation of Tube Radial Distribution Chromatography by Using a Commercially Available HPLC System
    Kan, Hyo
    Yamada, Kento
    Sanada, Nobuyuki
    Nakata, Koyo
    Tsukagoshi, Kazuhiko
    ANALYTICAL SCIENCES, 2018, 34 (02) : 239 - 241
  • [23] FLUORIDE CONCENTRATIONS IN COMMERCIALLY AVAILABLE PROCESSED BEVERAGES IN BRAZIL CONSUMED BY INFANTS
    Sampaio, Caio
    Botazzo Delbem, Alberto Carlos
    Cabral de Assis Salama, Isabel Cristina
    Cunha, Robson Frederico
    Pessan, Juliano Pelim
    FLUORIDE, 2019, 52 (03) : 467 - 473
  • [24] Evaluation of a commercially available automated sleep staging tool in healthy infants
    Terrill, Philip I.
    Suresh, Sadasivam
    Wilson, Stephen J.
    Cooper, David M.
    SLEEP AND BIOLOGICAL RHYTHMS, 2011, 9 (02) : 112 - 116
  • [25] Evaluation of a commercially available automated sleep staging tool in healthy infants
    Philip I. Terrill
    Sadasivam Suresh
    Stephen J. Wilson
    David M. Cooper
    Sleep and Biological Rhythms, 2011, 9 : 112 - 116
  • [26] Validity of a Commercially Available Inertial Measurement Unit for Vertical Jump Height Measurement
    Crisafulli, Gregory A.
    Taylor, Jeffrey B.
    Anh-Dung Nguyen
    Ford, Kevin R.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 436 - 436
  • [27] EVALUATION OF A COMMERCIALLY AVAILABLE RADIOIMMUNOASSAY KIT FOR MEASUREMENT OF DOXORUBICIN IN PLASMA
    PIALL, E
    AHERNE, GW
    MARKS, V
    CLINICAL CHEMISTRY, 1982, 28 (01) : 119 - 121
  • [28] THE MEASUREMENT OF PLASMA VISCOSITY - EXPERIENCE WITH 4 COMMERCIALLY AVAILABLE INSTRUMENTS
    ERNST, E
    MATRAI, A
    CLINICAL HEMORHEOLOGY, 1988, 8 (06): : 851 - 859
  • [29] MEASUREMENT OF MAGNETIC SUSCEPTIBILITIES WITH COMMERCIALLY AVAILABLE MILLI-OERSTEDMETERS
    WEIJTS, AGLM
    MASSEN, CH
    POULIS, JA
    APPLIED SCIENTIFIC RESEARCH, 1971, 24 (2-3): : 203 - &
  • [30] PROBLEMS IN MEASUREMENT OF SERUM DIGOXIN BY COMMERCIALLY AVAILABLE RADIOIMMUNOASSAY KITS
    KUBASIK, NP
    BRODY, BB
    BAROLD, SS
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 36 (07): : 975 - 977