Pentane measurement in ventilated infants using a commercially available system

被引:22
|
作者
Drury, JA
Nycyk, JA
Cooke, RWI
机构
[1] Institute of Child Health, Mersey Regional Neonatal Unit, Liverpool Women's Hospital, Liverpool L8 7SS, Crown Street
关键词
breath pentane; lipid peroxidation; preterm neonate;
D O I
10.1016/S0891-5849(96)00480-7
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of breath pentane as a marker of lipid peroxidation has recently been criticized. Problems encountered include the coelution of isoprene with pentane, contamination with exogenous pentane, and the influence of elevated oxygen concentration. The aim of this project was to investigate and evaluate the Chrompack 9001 Gas Chromatograph, using thermal desorption and cryofocussing and an Al2O3/KCl PLOT column with FID, for use in the measurement of breath pentane in ventilated preterm infants. We have clearly separated isoprene from n-pentane and used hydrocarbon free air to clear the airways and avoid contamination with exogenous pentane. Samples should be stored in Tedlar bags for a maximum of 48 h and on capped desorption tubes for no longer than 24 h. Patient variability was relatively high (mean 18%, n = 4); thus, all patients were sampled in duplicate. No correlation was found between fractional inspired oxygen concentration (FiO(2)) and exhaled pentane in preterm infants ventilated far respiratory distress syndrome. In conclusion, we feel that despite the pitfalls and technical difficulties, with careful attention to detail it is possible to reliably measure breath pentane in ventilated preterm infants as an index of lipid peroxidation. Copyright (C) 1997 Elsevier Science Inc.
引用
收藏
页码:895 / 900
页数:6
相关论文
共 50 条
  • [1] MEASUREMENT OF SYSTEM DEAD TIME WITH COMMERCIALLY AVAILABLE NIM MODULES
    NELSON, CB
    HARDIN, JM
    COATS, GI
    NUCLEAR INSTRUMENTS & METHODS, 1971, 97 (02): : 309 - &
  • [2] Measurement of active shoulder motion using the Kinect, a commercially available infrared position detection system
    Matsen, Frederick A., III
    Lauder, Alexander
    Rector, Kyle
    Keeling, Peyton
    Cherones, Arien L.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2016, 25 (02) : 216 - 223
  • [3] Measurement of Urinary Ammonium Using a Commercially Available Plasma Ammonium Assay
    Gruzdys, Valentinas
    Cahoon, Kenneth
    Pearson, Lauren
    Raphael, Kalani L.
    KIDNEY360, 2022, 3 (05): : 926 - 932
  • [4] Performance Analysis of VLC system using Commercially Available Components
    Khani, Talha Kaim
    Mangrio, Hyder Bux
    Umrani, Fahim Aziz
    2019 22ND IEEE INTERNATIONAL MULTI TOPIC CONFERENCE (INMIC), 2019, : 314 - 317
  • [5] EXPERIENCES USING COMMERCIALLY AVAILABLE EXPERT-SYSTEM FRAMEWORKS
    HOPFORD, RP
    JOURNAL OF THE OPERATIONAL RESEARCH SOCIETY, 1983, 34 (12) : A11 - A11
  • [6] MEASUREMENT OF FRACTIONATED URINARY ESTROGENS BY RADIO IMMUNOASSAYS USING COMMERCIALLY AVAILABLE REAGENTS
    DONAHUE, SV
    WORTHY, TE
    CLINICAL CHEMISTRY, 1982, 28 (07) : 1638 - 1638
  • [7] An Investigation of Measurement Techniques for Small Field Dosimetry Using Commercially Available Detectors
    Lim, S.
    Tang, G.
    LoSasso, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [8] A radioimmunoassay for the measurement of paclitaxel and taxanes in biological specimens using commercially available reagents
    Guillemard, V
    Landry, N
    Pagé, M
    ONCOLOGY REPORTS, 1999, 6 (06) : 1257 - 1259
  • [9] REASONABLY ACHIEVABLE MINIMUM DETECTABILITY USING A COMMERCIALLY AVAILABLE AUTOMATIC SYSTEM
    MOSCOVITCH, M
    SZALANCZY, A
    VELBECK, KJ
    HEALTH PHYSICS, 1987, 52 : S35 - S35
  • [10] 1500 Hz Adaptive optics system using commercially available components
    Schimpf, Armin
    Mickallef, Mickael
    Charton, Julien
    ADAPTIVE OPTICS SYSTEMS IV, 2014, 9148