High-intensity focused ultrasound (HIFU) has been emerging as an effective and noninvasive modality in cancer treatment with very promising clinical results. However, a small vessel in the focal region could be ruptured, which is an important concern for the safety of HIFU ablation. In this study, lesion formation in the polyacrylamide gel phantom embedded with different tubing (inner diameters of 0.76 mm and 3 mm) at varied flow speeds (17-339 cm/s) by HIFU ablation was photographically recorded. Produced lesions have decreased length (similar to 30%) but slightly increased width (similar to 6%) in comparison to that without the embedded tubing. Meanwhile, bubble activities during the exposures were measured by passive cavitation detection (PCD) at the varied pulse repetition frequency (PRF, 10-30 Hz) and duty cycle (DC, 10%-20%) of the HIFU bursts. High DC and low flow speed were found to produce stronger bubble cavitation whereas no significant influence of the PRF. In addition, high-speed photography illustrated that the rupture of tubing was produced consistently after the first HIFU burst within 20 ms and then multiple bubbles would penetrate into the intraluminal space of tubing through the rupture site by the acoustic radiation force. Alignment of HIFU focus to the anterior surface, middle, and posterior surface of tubing led to different characteristics of vessel rupture and bubble introduction. In summary, HIFU-induced vessel rupture is possible as shown in this phantom study; produced lesion sizes and shapes are dependent on the focus alignment to the tubing, flow speed, and tubing properties; and bubble cavitation and the formation liquid jet may be one of the major mechanisms of tubing rupture as shown in the high-speed photography.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] High-intensity focused ultrasound ablation of muscle in an anticoagulated swine model
    Kaye, Elena A.
    Solomon, Stephen B.
    Gutta, Narendra Babu
    Monette, Sebastien
    Ezell, Paula C.
    Maybody, Majid
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (01) : 89 - 93
  • [42] High-intensity focused ultrasound for endometrial ablation in adenomyosis: a clinical study
    Wu, Siyun
    Liu, Jun
    Liu, Xiaoshan
    Han, Yanhua
    [J]. FRONTIERS IN MEDICINE, 2024, 11
  • [43] Tissue ablation using an acoustic waveguide for high-intensity focused ultrasound
    Sommer, FG
    Sumanaweera, TS
    Glover, G
    [J]. MEDICAL PHYSICS, 1997, 24 (04) : 537 - 538
  • [44] High-intensity focused ultrasound shows promise for noninvasive tumor ablation
    Carol Lovegrove
    [J]. Nature Clinical Practice Oncology, 2006, 3 (1): : 8 - 9
  • [45] EXTRACORPOREAL ABLATION OF LIVER-TISSUE BY HIGH-INTENSITY FOCUSED ULTRASOUND
    SIBILLE, A
    PRAT, F
    CHAPELON, JY
    ELFADIL, FA
    HENRY, L
    THEILLERE, Y
    PONCHON, T
    CATHIGNOL, D
    [J]. ONCOLOGY, 1993, 50 (05) : 375 - 379
  • [46] The safety and ablation efficacy of ultrasound-guided high-intensity focused ultrasound ablation for desmoid tumors
    Zhang, Rong
    Chen, Jin-Yun
    Zhang, Lian
    Li, Ke-Quan
    Xiao, Zhi-Bo
    Mo, Shao-Jiang
    Chen, Li
    Chen, Wen-Zhi
    [J]. INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2021, 38 (02) : 89 - 95
  • [47] Effective ablation therapy of adenomyosis with ultrasound-guided high-intensity focused ultrasound
    Zhang, Xin
    Li, Kequan
    Xie, Bin
    He, Min
    He, Jia
    Zhang, Lian
    [J]. INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2014, 124 (03) : 207 - 211
  • [48] Hyperecho in ultrasound images during high-intensity focused ultrasound ablation for hepatocellular carcinomas
    Fukuda, Hiroyuki
    Numata, Kazushi
    Nozaki, Akito
    Kondo, Masaaki
    Morimoto, Manabu
    Tanaka, Katsuaki
    Ito, Ryu
    Ohto, Masao
    Ishibashi, Yoshiharu
    Oshima, Noriyoshi
    Ito, Ayao
    Zhu, Hui
    Wang, Zhi-Biao
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E571 - E575
  • [49] High-intensity focused ultrasound and cryotherapy
    Murat, F. J.
    [J]. CRITICAL REVIEWS IN ONCOLOGY HEMATOLOGY, 2011, 78 : S11 - S11
  • [50] High-intensity focused ultrasound therapy
    Cheung, Vincent Y. T.
    [J]. BEST PRACTICE & RESEARCH CLINICAL OBSTETRICS & GYNAECOLOGY, 2018, 46 : 74 - 83