Thermal performance and cost analysis of a multi-layered solid-PCM thermocline thermal energy storage for CSP tower plants

被引:77
|
作者
Zhao, Bing-chen [1 ,2 ]
Cheng, Mao-song [1 ]
Liu, Chang [1 ,2 ]
Dai, Zhi-min [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Appl Phys, Shanghai 201800, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
关键词
Concentrating solar power; Thermal energy storage; Encapsulated phase change material; Multi-layered solid-PCM thermocline; Packed-bed configuration; Cost optimization; MOLTEN-SALT THERMOCLINE; PHASE-CHANGE MATERIAL; CONCENTRATING SOLAR POWER; ENCAPSULATED SPHERICAL CONTAINERS; LATENT-HEAT STORAGE; PACKED-BED; NUMERICAL-ANALYSIS; SYSTEM; CAPSULES; OPTIMIZATION;
D O I
10.1016/j.apenergy.2016.06.034
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Thermocline storage in packed-bed is taken into consideration for cost reduction of thermal energy storage (TES) system in concentrating solar power (CSP). With a novel packed-bed configuration proposed recently, multi-layered solid-PCM (MLSPCM) thermocline TES is regarded as a more cost-effective alternative for current TES due to its lower thermocline degradation, which results in a higher energy utilization during the cyclic operation of the system comparing to other thermocline TES patterns. Thermal performance of several MLSPCM thermocline TES system with specific packed-bed configurations have been numerically evaluated both on pilot and practical scale. In this work, transient thermal behaviors of charging and discharging process in a cyclic operating state of a practical scale MLSPCM thermocline TES is investigated using a modified one-dimensional dispersion-concentric (D-C) model, while a comprehensive cost model is adopted to estimate capital cost of TES system. The influence of packed-bed configuration on several evaluation indexes of system performance such as cyclic operating time duration, total capacity factor and capital cost per kW ht are explored based on parametric studies. Optimum design configurations are identified to minimize capital cost per kW ht on the specific operating requirements. A cost comparison among different thermocline TES patterns as well as the two-tank TES are presented. The results show that the MLSPCM thermocline TES with an optimum packed-bed configuration is more cost-competitive than the two tank TES and any other thermocline TES systems. Overall, this study illustrates a methodology for packed-bed configuration optimization of a practical-scale MLSPCM thermocline TES and provide a design reference on cost-effective TES system for current CSP tower plants. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:784 / 799
页数:16
相关论文
共 50 条
  • [1] Multi-layered solid-PCM thermocline thermal storage concept for CSP plants. Numerical analysis and perspectives
    Galione, P. A.
    Perez-Segarra, C. D.
    Rodriguez, I.
    Oliva, A.
    Rigola, J.
    APPLIED ENERGY, 2015, 142 : 337 - 351
  • [2] Numerical evaluation of multi-layered solid-PCM thermocline-like tanks as thermal energy storage systems for CSP applications
    Galione, P.
    Perez-Segarra, C.
    Rodriguez, I.
    Torras, S.
    Rigola, J.
    INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, SOLARPACES 2014, 2015, 69 : 832 - 841
  • [3] Multi-layered solid-PCM thermocline thermal storage for CSP Numerical evaluation of its application in a 50 MWe plant
    Galione, P. A.
    Perez-Segarra, C. D.
    Rodriguez, I.
    Torras, S.
    Rigola, J.
    SOLAR ENERGY, 2015, 119 : 134 - 150
  • [4] Optimization of thermal performance in thermocline tank thermal energy storage system with the multilayered PCM(s) for CSP tower plants
    Elfeky, K. E.
    Li, Xinyi
    Ahmed, N.
    Lu, Lin
    Wang, Qiuwang
    APPLIED ENERGY, 2019, 243 : 175 - 190
  • [5] Cyclic performance of cascaded and multi-layered solid-PCM shell-and-tube thermal energy storage systems: A case study of the 19.9 MWe Gemasolar CSP plant
    Tehrani, S. Saeed Mostafavi
    Shoraka, Yashar
    Nithyanandam, Karthik
    Taylor, Robert A.
    APPLIED ENERGY, 2018, 228 : 240 - 253
  • [6] Techno-economic Performance Evaluation of Solar Tower Plants with Integrated Multi-layered PCM Thermocline Thermal Energy Storage - A Comparative Study to Conventional Two-tank Storage Systems
    Guedez, Rafael
    Ferruzza, Davide
    Arnaudo, Monica
    Rodriguez, Ivette
    Perez-Segarra, Carlos D.
    Hassar, Zhor
    Laumert, Bjoern
    SOLARPACES 2015: INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2016, 1734
  • [7] A new thermocline-PCM thermal storage concept for CSP plants. Numerical analysis and perspectives
    Galione, P. A.
    Perez-Segarra, C. D.
    Rodriguez, I.
    Lehmkuhl, O.
    Rigola, J.
    PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 790 - 799
  • [8] Comparative study of single and multi-layered packed-bed thermal energy storage systems for CSP plants
    Abdulla A.
    Reddy K.S.
    Applied Solar Energy, 2017, 53 (3) : 276 - 286
  • [9] Numerical comparison between single PCM and multi-stage PCM based high temperature thermal energy storage for CSP tower plants
    Elfeky, K. E.
    Ahmed, N.
    Wang, Qiuwang
    APPLIED THERMAL ENGINEERING, 2018, 139 : 609 - 622
  • [10] Numerical investigation of the melting temperature effect on the performance of thermocline thermal energy storage tank for CSP
    Elfeky, K. E.
    Ahmed, N.
    Naqvi, S. M. A.
    Wang, Qiuwang
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 4715 - 4720