Traveling wave protection based on asynchronously sampled time difference of arrival of modulus traveling waves in per unit line length

被引:6
|
作者
Liang Rui [1 ,2 ]
Wang Zheng [1 ,2 ]
Peng Nan [1 ,2 ]
Zare, Firuz [3 ]
Liu Xiaowen [4 ]
Liu Chenglei [5 ]
机构
[1] China Univ Min & Technol, Sch Elect & Power Engn, Xuzhou 221116, Jiangsu, Peoples R China
[2] Jiangsu Prov Lab Elect & Automat Engn Coal Min, Xuzhou 221116, Jiangsu, Peoples R China
[3] Univ Queensland, Brisbane, Qld 4072, Australia
[4] China Univ Min & Technol, Sch Informat & Control Engn, Xuzhou 221116, Jiangsu, Peoples R China
[5] State Grid Jiangsu Elect Power Maintenance Branch, Xuzhou Div, Xuzhou 221000, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Traveling wave protection; Transmission networks; Modulus traveling waves; Time difference of arrival; PARALLEL TRANSMISSION-LINES; HIGH-SPEED PROTECTION; DISTANCE PROTECTION; SCHEME; TRANSIENTS; ALGORITHM;
D O I
10.1016/j.epsr.2018.08.013
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Traditional traveling wave protection schemes are susceptible to many factors such as network topology change, environment interference and inaccurate identification of wave fronts, which may lead to mal-operation of protection. In addition, most traveling wave protection schemes need accurate synchronous measurement which adds to the implementation cost. This paper proposes a traveling wave protection for high voltage power grids based on the time difference of arrival (TDOA) of zero-mode and aerial-mode traveling wave. First, the time difference of arrival of the modulus voltage traveling waves (MVTWs) asynchronously sampled at each bus is captured. With the minimum TDOA, the key bus and fault area can be firstly determined. Then, the TDOA of the line in per unit length is defined as the ratio between the difference of the TDOAs at both terminal buses and line length. Finally, as for one case that key bus connects with no other bus, the line corresponding to the minimum TDOA of all the lines in the fault area is determined as the fault line. As for the other case, the calculated line length should be compared with the actual one to detect the fault line. PSCAD/EMTDC is used to conduct fault simulations and the calculation results verify that the proposed scheme is not affected by fault resistances, inception angles and distances. In addition, the operation time of the scheme does not exceed 20 ms, which makes it applicable for actual power grid protection.
引用
收藏
页码:250 / 258
页数:9
相关论文
共 50 条
  • [41] Single-terminal line protection for UHVDC power transmission based on voltage backward traveling wave
    Dai Z.
    Liu N.
    Liu Y.
    Lu H.
    Cao H.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2019, 39 (09): : 80 - 87
  • [42] New directional protection based on traveling wave current polarity comparison used on HVDC transmission line
    Quan, Yusheng
    Wang, Huan
    Li, Xuepeng
    He, Qiuyu
    Zhang, Xianjun
    Gaodianya Jishu/High Voltage Engineering, 2006, 32 (09): : 106 - 110
  • [43] The influence of corona effect on traveling wave based transmission line protection distance to fault error calculation
    Siozinys, Vytautas
    Markevicius, Linas A.
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (7B): : 208 - 210
  • [44] Line Pilot Protection of Flexible DC Grid Based on Traveling-Wave JS']JS Divergence
    Mao, Chunxiang
    Wei, Peng
    Liu, Ruopeng
    Cai, Bin
    Xu, Hui
    IEEE ACCESS, 2022, 10 : 129269 - 129278
  • [45] Adaptive traveling wave-Based algorithm for time alignment of transmission line fault records
    Lopes, Felipe V.
    Honorato, Tiago R.
    Cunha, Gustavo A.
    Ribeiro, Nilo S. S.
    Lima, Paulo
    Coelho, Andrei
    Becker, Daniel
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 196
  • [46] A transmission line icing thickness measurement method based on the traveling wave transmission time differences
    Zeng, Xiangjun
    Wu, Zhihua
    Feng, Kaihui
    Qin, Xiao'an
    Hu, Xiang
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2010, 34 (10): : 81 - 83
  • [47] A Pilot VSC-HVDC Line Protection Principle Based on Similarity of Time-Frequency Matrix of Initial Current Traveling Wave
    Zhang, Yunqi
    Wang, Congbo
    Yu, Yue
    Yang, Guosheng
    Cao, Hong
    2022 IEEE SUSTAINABLE POWER AND ENERGY CONFERENCE (ISPEC), 2022,
  • [48] Non-unit traveling wave protection for flexible HVDC lines based on the ratio of the waveform fitting residual
    Li, Haifeng
    Jiang, Huimin
    Liang, Yuansheng
    Xu, Yongzhi
    Wang, Gang
    ELECTRIC POWER SYSTEMS RESEARCH, 2023, 218
  • [49] A Novel Traveling Wave Fault Location Method Based on Distance Proportion and Time Difference for Distribution Network
    Cai, Jun
    Zeng, Xiangjun
    Yang, Yi
    Deng, Shuguang
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 1200 - 1205
  • [50] A High Voltage Transmission Line Length Correction Method for Traveling Wave Fault Location Based on Binocular Vision
    Li, Zhenxing
    Hu, Cong
    Zhu, Yi
    Cui, Xiaolin
    Weng, Hanli
    Dianwang Jishu/Power System Technology, 2024, 48 (10): : 4387 - 4396