Preferential dissolution of aluminum under the tip of an atomic force microscope

被引:16
|
作者
Roue, L [1 ]
Chen, LL [1 ]
Guay, D [1 ]
机构
[1] INRS ENERGIE & MAT,VARENNES,PQ J3X 1S2,CANADA
关键词
D O I
10.1021/la950234+
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The corrosion of aluminum in a chloride-containing solution was studied by atomic force microscopy. Two different Al substrates were used, namely thin Al films deposited on a glass substrate and polished commercial Al plates. in each case, it is shown that the interaction of the microscope tip with the Al substrate causes the removal of Al from beneath the tip. This Al removal does not occur when the Al substrates are scanned in air or in pure demineralized water. The fate of Al removal varies almost linearly with the load applied by the cantilever tip on the Al surface in the range between 0 and 80 x 10(-9) N. At a given load, increasing the scanning rate causes an increase in the rate of Al removal to a value of about 3 Hz. The rate of Al removal does not increase much for scanning rates above that value, The size of the smallest features that can be produced on a thin Al film is about 150 nm. The maximum resolution attainable seems to be limited more by the shape of the tip used to engrave the Al than by anything else.
引用
收藏
页码:5818 / 5823
页数:6
相关论文
共 50 条
  • [31] Estimation of three-dimensional atomic force microscope tip shape from atomic force microscope image for accurate measurement
    Harada, Yasuhiko
    Sone, Hayato
    Hosaka, Sumio
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2008, 47 (07) : 6186 - 6189
  • [32] Estimation of three-dimensional atomic force microscope tip shape from atomic force microscope image for accurate measurement
    Harada, Yasuhiko
    Sone, Hayato
    Hosaka, Sumio
    Japanese Journal of Applied Physics, 2008, 47 (7 PART 3): : 6186 - 6189
  • [33] ATOMIC-FORCE MICROSCOPE INTEGRATED WITH A SCANNING ELECTRON-MICROSCOPE FOR TIP FABRICATION
    WALTERS, DA
    HAMPTON, D
    DRAKE, B
    HANSMA, HG
    HANSMA, PK
    APPLIED PHYSICS LETTERS, 1994, 65 (06) : 787 - 789
  • [34] Lewy Bodies under Atomic Force Microscope
    Tercjak, Agnieszka
    Bergareche, Alberto
    Caballero, Cristina
    Tunon, Teresa
    Linazasoro, Gurutz
    ULTRASTRUCTURAL PATHOLOGY, 2014, 38 (01) : 1 - 5
  • [35] Atomic force microscope tip spontaneous retraction from dielectric surfaces under applied electrostatic potential
    Lyuksyutov, S. F.
    Paramonov, P. B.
    Mayevska, O. V.
    Reagan, M. A.
    Sancaktar, E.
    Vaia, R. A.
    Juhl, S.
    ULTRAMICROSCOPY, 2006, 106 (10) : 909 - 913
  • [36] FORCE OSCILLATIONS AND LIQUID STRUCTURE IN SIMULATIONS OF AN ATOMIC-FORCE MICROSCOPE TIP IN A LIQUID
    GELB, LD
    LYNDENBELL, RM
    CHEMICAL PHYSICS LETTERS, 1993, 211 (4-5) : 328 - 332
  • [37] Continuous Measurement of Atomic Force Microscope Tip Wear by Contact Resonance Force Microscopy
    Killgore, Jason P.
    Geiss, Roy H.
    Hurley, Donna C.
    SMALL, 2011, 7 (08) : 1018 - 1022
  • [38] A new atomic force microscope probe with force sensing integrated readout and active tip
    Onaran, AG
    Balantekin, M
    Lee, W
    Hughes, WL
    Buchine, BA
    Guldiken, RO
    Parlak, Z
    Quate, CF
    Degertekin, FL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (02):
  • [39] A TUNNELING ATOMIC FORCE MICROSCOPE WITH INERTIAL TIP-TO-SENSOR APPROACH
    PROBST, O
    GRAFSTROM, S
    KOWALSKI, J
    NEUMANN, R
    WORTGE, M
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1991, 9 (02): : 626 - 630
  • [40] Elastic deformations of tip and sample during atomic force microscope measurements
    Heuberger, M
    Dietler, G
    Schlapbach, L
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1996, 14 (02): : 1250 - 1254